VIASYS Respiratory Care Inc AVEA Respirateur artificiel
Fabricant:
Modèle:
AVEA
Date:
2006
Catégorie:
Groupe:
Description:
Ventilator System
Information
The AVEA is a fourth generation, servo-controlled, software-driven Ventilator. It has a dynamic range of breathing gas delivery that provides for neonatal through adult patients. Its revolutionary user interface module (UIM) provides maximum flexibility with simple operator interaction. It has a flat panel color LCD with real time graphic displays and digital monitoring capabilities, a touch screen for easy interaction, membrane keys and a dial for changing settings and operating parameters. A precision gas delivery engine with servo controlled active inhalation and exhalation improves performance over previous generations. The AVEA has been designed to function using most commonly available accessories. It is easy to clean and its design does not allow liquids to pool on the casing, reducing the likelihood of fluid leakage into the body of the Ventilator.

plus

Manuel de l'utilisateur
Type manuel:
Manuel de l'utilisateur
Pages:
196
Taille:
4.25 Mbytes (4451554 Bytes)
Langue:
english
Révision:
D
Manuel-ID:
L2786
Date:
01 février 2007
Qualité:
Électronique de documents, numérisation sans, bien lisible.
Date de transfert:
10 mars 2018
MD5:
18b4f2b0e992055904d54576908da5f0
Téléchargements:
153
Information
Revision History ... iii Warranty ... iv Notices ... vii Safety Information ... ix Equipment Symbols ... xi Chapter 1 Introduction ... 1-1 Some AVEA Features ... 1-2 Chapter 2 Unpacking & Setup ... 2-1 Ventilator Assembly & Physical Setup ... 2-1 Setting Up the Front of the Ventilator ... 2-3 Front Panel Connections ... 2-7 Setting Up the Rear of the Ventilator ... 2-14 User Verification Test ... 2-26 AVEA User Verification Test Checklist ... 2-33 AVEA:Troubleshooting ... 2-34 Chapter 3 Ventilator Operation ... 3-1 Membrane Buttons and LEDs ... 3-1 Patient Setup ... 3-9 Ventilation Setup ... 3-10 Setting the Ventilation Breath Type and Mode ... 3-14 Primary Breath Controls ... 3-31 Advanced Settings ... 3-37 Independent Lung Ventilation (ILV) ... 3-44 Chapter 4 Monitors, Displays and Maneuvers ... 4-1 Graphic Displays ... 4-1 Digital Displays ... 4-20 Main Screen Displays ... 4-26 Chapter 5 Infant NCPAP ... 5-1 Overview ... 5-1 Circuit Compatibility ... 5-1 General Specifications ... 5-1 Initiating Nasal CPAP ... 5-3 Monitors ... 5-5 Graphics ... 5-6 Chapter 6 Alarms and Indicators ... 6-1 Status Indicators ... 6-1 Messages ... 6-3 Alarms ... 6-4 Alarm Controls ... 6-5 Alarm Types ... 6-6 Chapter 7 Maintenance and Cleaning ... 7-1 Cleaning & Sterilization ... 7-1 Disposable Parts ... 7-2 Other Accessories ... 7-2 Recommended Periodic Maintenance ... 7-3 Battery Care ... 7-4 Fuses ... 7-6 Appendix A Contact & Ordering Information ... A-1 How to Call for Service ... A-1 Ordering Parts ... A-2 Appendix B Specifications ... B-1 Pneumatic Supply ... B-1 Electrical Supply ... B-1 Data Input / Output ... B-2 Atmospheric & Environmental Specifications ... B-5 Physical Dimensions ... B-5 Accessories ... B-6 Appendix C Pneumatic Diagram ... C-1 Gas Delivery Engine ... C-1 Appendix D Monitor Ranges and Accuracies ... D-1 Appendix E Sensor Specifications & Circuit Resistance ... E-1 VarFlex® Sensor Specifications ... E-1 Hot Wire Flow Sensor Specifications ... E-2 Circuit Resistance (per EN794 –1) ... E-2 Appendix F AVEA Message Bar Text ... F-1 Appendix G Adjusting Barometric Pressure for Altitude ... G-1 Appendix H Advanced Pulmonary Mechanics Monitored Parameters ... H-1 Appendix I Glossary ... I-1 Index ... 3

plus

manuel de réparation
Type manuel:
manuel de réparation
Pages:
277
Taille:
19.48 Mbytes (20429688 Bytes)
Langue:
english
Révision:
C
Manuel-ID:
L1524
Date:
01 janvier 2006
Qualité:
Électronique de documents, numérisation sans, bien lisible.
Date de transfert:
10 mars 2018
MD5:
8f2d3b1a7730b0ed10404e5e6695e6e9
Téléchargements:
139
Information
Revision History ... iii Notices ... vi Warranty ... viii Chapter 1 Introduction ... 1-1 Safety Information ... 1-1 Equipment Symbols ... 1-4 Chapter 2 Theory of Operation ... 2-1 General Description ... 2-1 High Level Design ... 2-3 Detail Design ... 2-5 Chapter 3 Installation Instructions ... 3-1 Stand Assembly ... 3-1 Comprehensive Assembly Instructions ... 3-4 Customer Transport Cart Kit P/N 11372 ... 3-8 “E” Cylinder Bracket Assembly Instructions ... 3-14 Assembly Instructions for Comprehensive Cart Tank Rack Bracket ... 3-18 AVEA Unpacking Instructions ... 3-19 SETTING UP THE REAR OF THE VENTILATOR ... 3-22 Medical Gas Connector Kit Installation Instructions ... 3-22 Air and Heliox Tethered “Smart” Connector Installation Instructions ... 3-25 Heliox “Smart” Connector Installation Instructions (DISS P/N 51000-40918) ... 3-27 Chapter 4 Assembly and Disassembly ... 4-1 General Instructions and Warnings ... 4-1 Recommended Tools & Equipment ... 4-1 Gas Delivery Engine P/N 16222A ... 4-4 Ventilator wheeled base ... 4-10 Internal Batteries P/N 68339A ... 4-10 Compressor/Scroll Pump P/N 51000-09750A ... 4-15 Enhanced Patient Monitor (EPM) Board P/N 51000-40848A ... 4-1 Fan Assembly P/N 51000-40861 ... 4-18 Power Supply P/N 16388 ... 4-19 Exhalation Valve P/N 16319 and Exhalation Flow Sensor Assembly P/N 51000-40023 ... 4-22 Exhalation housing P/N 20030 ... 4-22 Heater Assembly P/N 51000-40824 ... 4-24 Microswitch, Top Cover P/N 68294 ... 4-24 EMI Shield ... 4-25 Front Interface Panel P/N 51000-40635 ... 4-25 Transition board with harness P/N 16216 ... 4-27 Alarm Speaker P/N 51000-40818 ... 4-28 Nebulizer Assembly P/N 51000-40026 ... 4-29 Accumulator P/N 51000-40748 ... 4-31 Secondary Alarm Installation (KitP/N 16316) ... 4-32 General Instructions and Warnings ... 4-32 Recommended Tools & Equipment ... 4-32 Functional testing of the Secondary Alarm Assembly. ... 4-34 Chapter 5 Operational Verification Procedure (OVP) ... 5-1 Set up ... 5-1 User Verification Tests (UVT) ... 5-1 Return Flow Correction to BTPS upon completion of testing. ... 5-10 User Interface Module (UIM) Verification ... 5-10 AVEA Assembly and Operational Verification Test Checklist ... 5-12 Field replacement and test of the AVEA Compressor Assembly ... 5-12 Checkout Sheet – AVEA Compressor Replacement ... 5-16 Power Indicators and Charging Verification ... 5-17 Battery Run Procedure ... 5-17 Air/Oxygen Inlet Pressure Verification ... 5-18 Breath Rate Verification. ... 5-19 Blending Accuracy Verification ... 5-19 PEEP Verification ... 5-19 AVEA Assembly and Operational Verification Test Checklist ... 5-20 Chapter 6 AVEA Software Upgrade ... 6-1 Requirements: ... 6-1 Procedure: ... 6-2 Software Install Verification AVEA Ventilators ... 6-11 Installation Verification ... 6-11 Confirmation checks ... 6-11 Verification and Calibration ... 6-12 Test and Access of the Security System ... 6-12 Chapter 7 Calibration ... 7-1 Screen Calibration Procedure ... 7-1 Transducer Calibration ... 7-4 Calibration setup ... 7-5 Flow and Exhalation valve Characterization/Hysteresis Test ... 7-18 Exhalation Valve Characterization Test ... 7-19 Hysteresis Test ... 7-20 Exhalation Valve Leak Test ... 7-21 Chapter 8 Preventive Maintenance ... 8-1 Replacing the O2 and Air/Heliox filters. ... 8-2 Replacing the Compressor Inlet & Outlet filters ... 8-4 Replacing the Exhalation Diaphragm P/N 16240 ... 8-5 Chapter 9 Troubleshooting ... 9-1 Chapter 10 Parts List ... 10- Appendix A ... A-1 Contact & Ordering Information ... A-1 Diagrams and Schematics ... A-2 Specifications ... A-55 AVEA Message Bar Text ... A-66 Adjusting Barometric Pressure for Altitude ... A-68 Monitor Ranges and Accuracies ... A-69 Sensor Specifications & Circuit Resistance ... A-75 Hot Wire Flow Sensor Specifications ... A-76 Circuit Resistance (per EN794 –1) ... A-77 Advanced Pulmonary Mechanics Monitored Parameters ... A-78 Glossary ... A-85 Index ... 1

plus

Commentaires (0)

Pas encore de commentaires. Soyez le premier !

Ajouter un commentaire

* Information obligatoire
1000
Image Captcha