Description:
Defiillator Transcutaneous Pacemaker Analyzer

Information

The QA-40M and QA-45 Analyzers are precision instruments for testing defibrillators and, additionally with the QA-45 transcutaneous pacemakers. They are designed to be used by trained technicians. The defibrillator function of the QA-40M and QA-45 measures the energy output, and ensures that the defibrillator complies with specified requirements. QA-40M and QA-45 have built-in load resistances of 50 ohms, which roughly correspond to the impedance of the human body. The defibrillator pads are placed on the analyzers’ contact plates. Thus, the defibrillator is connected through the load resistance. When the defibrillator is discharged, the analyzers calculate and display the energy delivered. In the pacer function the QA-45 tests all types of transthoracic pacemakers. The testing is menu driven, and simple to operate. QA-45 measures and displays a pulse’s amplitude, rate, energy and width. It also conducts demand sensitivity tests, measuring and displaying refractory periods, and immunity tests, which determine the pacemaker’s susceptibility to 50/60 Hz interference. Testing with the QA-40M/45 is usually a matter of setting up the preferred simulation parameters. Using PRO-Soft QA-40M.45 simplifies the process by providing an all Windows-based environment through which simulation parameters are created by the user and sent to the QA-40M/45 unit.

plus

Manuel de l'utilisateur
Type manuel:
Manuel de l'utilisateur
Pages:
51
Taille:
646.69 Kbytes (662208 Bytes)
Langue:
english
Révision:
Manuel-ID:
15035
Date:
1977 01 01
Qualité:
Électronique de documents, numérisation sans, bien lisible.
Date de transfert:
2019 08 16
MD5:
88638cfb8cf95ead20a2a0e20240859d
Téléchargements:
746

Information

MANUAL REVISION RECORD ... 5 1. ABOUT PRO-Soft QA-40M.45 ... 7 1.1 Introduction ... 7 1.2 PRO-Soft QA-40M.45 ... 7 1.3 About your Manual ... 8 1.4 Updating PRO-Soft Program Files ... 8 2. GETTING STARTED ... 9 2.1 System Requirements ... 9 2.2 Installing PRO-Soft ... 9 2.3 Initial Startup ... 10 2.4 Option Settings ... 11 2.5 Printing Test Results ... 14 3. TESTING SETUP ... 15 3.1 Equipment Setup ... 15 3.2 Power ... 15 3.3 Internal Paddles ... 16 3.4 Special Contacts ... 16 3.5 Initializing Remoting -Defibrillator Mode ... 16 3.6 Initializing Remoting -Pacemaker Mode /QA-45 only) ... 17 4. MANUAL TESTING ... 18 4.1 Defibrillator Discharge (Energy) Test ... 18 4.2 ECG Performance Test ... 20 4.3 Shock Advisory Algorithm Test ... 22 4.4 Pacemaker Accuracy Test /QA-45 Only) ... 23 4.5 Pacemaker Sensitivity Test /QA-45 Only) ... 24 4.6 Pacemaker Refractory Period Test /QA-45 Only) ... 25 5. SEQUENCE TESTING ... 28 5.1 Sequence Form Window ... 28 5.2 Defibrillator Test Sequence Setup ... 29 5.3 Pacemaker Test Sequence Setup ... 30 5.4 Running a Sequence ... 32 5.5 Sequence File Management ... 33 6. EMERGENCY SEQUENCE TRAINING ... 34 6.1 Sequence Setup ... 34 6.2 Running Emergency Sequences 1 - 7 ... 35 6.3 Running Cardio Sequence ... 36 7. SELECT CLOSE TO TERMINATE THE TEST AND RETURN TO THE MAIN SCREEN. ... 36 8. CHECKLISTS ... 37 8.1 Checklist Form Window ... 37 8.2 Checklist Files Management ... 37 9. PROTOCOLS ... 39 9.1 Protocol Form Window ... 39 9.2 Protocol Database ... 41 9.3 Protocol File Management ... 42 9.4 Importing Data ... 43 10. TROUBLESHOOTING ... 45 APPENDIX A: ERROR REPORT FORM, PRO-Soft QA-40M.45 ... 47 APPENDIX B: SUGGESTION FORM, PRO-Soft QA-40M.45 ... 49

plus