Keithley 2182A Multimètre numérique
Manufacturer:
No picture available!
Maybe you can upload a pic for the
Keithley 2182A ?
If you have any other manuals for the
Keithley 2182A you can upload the files here .
Model:
2182A
Date:
2017
Category:
Group:
Description:
Nanovoltmeter
Information
The Model 2182 is a 7 1⁄2-digit high-performance digital
nanovoltmeter. It has two input
channels to measure voltage and temperature. The measurement
capabilities of the Model 2182
are explained in Section 2 of this manual (see “Measurement
overview”).
Features of the Model 2182 Nanovoltmeter include:
•
Ratio — Provides comparison readings between two voltage
inputs. Ratio performs
V1/V2.
•
Delta — Provides average difference of Channel 1 inputs.
Delta performs
(V1t1–V1t2)/2.
•
Enhanced Delta, Pulse Delta, and Differential Conductance —
The following tests can be performed when using a Model
2182 2182A/with a Model 6220 or 6221 Current Source:
—
Delta - Uses a square wave output and a 3-point measurement
algorithm to cancel the effects of thermal EMFs.
—
Pulse Delta /6221 and 2182A only) - Provides a pulse output
and a 3-point (or 2-point) measurement algorithm for testing
of temperature sensitive Device Under Test (DUT).
—
Differential Conductance - Uses a differential current
output and a 3-point moving
average algorithm to perform differential measurements.
•
mX+b and Percent — These calculations provide mathematical
manipulation of
readings.
•
Relative — Null offsets or establish baseline values.
•
Buffer — Store up to 1024 readings in the internal buffer.
•
Limits — Set high and low reading limits to test devices.
•
Internal Scanning — Scan the two input channels of the
Model 2182,
•
External Scanning — Scan the channels or matrix points of
Keithley Model 7001.7002
switching cards.
•
Setup Storage — Two instrument setups (user and factory
defaults) can be saved and
recalled.
•
Analog Output — With analog output gain set to one, a full
range input will result in a
1V analog output.
•
Remote Interface — The Model 2182 can be controlled using
the IEEE-488 Interface
(GPIB) or the RS-232 Interface.
•
GPIB Programming Language — When using the GPIB, the
instrument can be
programmed using the SCPI or model 182 (DDCs) programming
language.
•
Closed-cover Calibration — The Model 2182 can be calibrated
from either the front
panel or the GPIB.
Manual type:
Manuel de l'utilisateur
Pages:
339
Size:
1.97 Mbytes (2066487 Bytes)
Language:
english
Revision:
B
Manual-ID:
2182A-900-01
Date:
01 May 2017
Quality:
Électronique de documents, numérisation sans, bien lisible.
Upload date:
22 August 2018
MD5:
fafdfed71d7a8e85ec9b88b59893d53b
Downloads:
923
Information
This User’s Manual supports both the Models 2182 and(2182A:
References to the Model 2182 apply to both the Models 2182
and 2182A,
References to the Model 2182.2182A apply to the Model 2182
with firmaware version A10
or higher, and the Model 2182A with firmware version C01 or
higher.
References to the Model 2182A applies to the Model 2182A
with firmware version C01 or higher.
Ajouter un commentaire
Conditions générales
Ces conditions générales contiennent des règles sur l'affichage des commentaires. En soumettant un commentaire, vous déclarez que vous approuvez ces règles :
- Bien que l'administrateur tente de modérer les commentaires, il est impossible que chaque commentaire ait été modéré à un moment donné.
- Vous reconnaissez que tous les commentaires expriment les points de vue et les opinions de l'auteur original et non ceux de l'administrateur.
- Vous acceptez de ne publier aucun contenu qui est sciemment faux, obscène, haineux, menaçant, harcelant ou envahissant la vie privée d'une personne.
- L'administrateur a le droit de modifier, déplacer ou supprimer tout commentaire pour une raison quelconque et sans préavis.
Le non-respect de ces règles peut entraîner l'interdiction de tout commentaire ultérieur.
Ces conditions générales sont sujettes à changement à tout moment et sans préavis.
Commentaires