Advantest Corporation R6551 Multimètre numérique
Fabricant:
Image 1 de 1
Si vous avez d'autres photos ou manuels pour les
Advantest Corporation R6551 vous pouvez télécharger les fichiers ici .
Modèle:
R6551
Date:
1988
Catégorie:
Groupe:
Description:
Information
R6551/R6551EMC (=this equipment) is a high-performance
Digital multimeter which measures DC voltage, AC voltage
(true root-mean-square (rms) value), resistance (using
two-wire and four-wire conductors), DC current, and AC
current (true rms value). This equipment displays measured
values in up to 5 1/2 digits of 319999.
In addition to the above measuring functions, this equipment
has the functions of NULL operation to correct the off-set
and measure relative values, and SCALE operation to display
the relative ratios. It also has the external trigger
function and a measurement end signal output connector. This
equipment sets the integration time selected depending on
the necessary measurement accuracy, and allows high-speed
measurement (resulting in 4 1/4 digits) for 100 times per
second.
In R6551EMC, measurement with few generation of the
radiation noise can be done by reinforcing the shield of the
front panel and the frame.
This equipment is provided with a digital Interface for
programmable instrumentation called general-purpose
Interface bus (GPIB) as a standard attachment.
The GPIB allows this equipment to set measurement
parameters, output data, and make up an automatic
instrumentation system using a personal or system computer.
R6551 is provided with the OPTOI for BCD parallel data
output as an option. Features:
- Displays measured values in up to 5 1/2 digits of 319999
with 3ppm resolution.
- Allows highly sensitive measurement to be done with DC
voltage resolution of 1uV and resistance resolution of 1MU.
- Makes stable measurement through integral AD conversion
for integration time selection and setting.
- Performs high-speed sampling for 100 times per second and
displays it in up to 4 1/2 digits.
- Measures resistance using a four-wire measuring system not
affected by the resistance of the measurement cable
- Measures AC voltage and current by a true rms value
measuring method.
- Measures AC voltages within the wide frequency band range
from 20Hz to 300kHz.
- Displays output data, units, and functions with clear
green LEDs.
- Optimizes a measuring range at high speed using a
high-speed auto-range.
- Provides the NULL function to correct the off-set promptly.
- Provides the SCALE function to set and calculate 100%
values promptly.
- Optimized to be integrated into a full-remote automatic
instrumentation system using the GPIB Interface provided as
a standard attachment.
- Has external trigger input and measurement end signal
output terminals.
- Provided with BCD parallel data output as an option.
/R6551 only)
- Has the setting storage function to store panel setting
states in the built-in non-volatile memory.
- Can be calibrated by the program via the GPIB without
opening the case, and has the storage for calibration data
protected by the dedicated switch.
- Allows high-precision measurement using the high-precision
reference voltage and a thin film resistor.
- Can be connected with a cable-lock type input cable (to
the front panel) to prevent danger.
- Uses input terminals with screw-type binding posts for
sensors and general-purpose input lines on the rear panel,
allowing one of the input terminals on the front and rear
panels to be set selectively by the panel switch.
- Even when DUT receives the effect easily from
electromagnetic surroundings environments to suppress the
generation of the radiation noise small in R6551EMC, steady
measurement is possible.
Type manuel:
Manuel de l'utilisateur
Pages:
126
Taille:
3.15 Mbytes (3306589 Bytes)
Langue:
english
Révision:
Manuel-ID:
FOE-8311246D01
Date:
1988 09 30
Qualité:
Document scanné, tous les lisible.
Date de transfert:
2017 12 25
MD5:
6e0e68ca70fc4ea245cc3b768d01220e
Téléchargements:
758
Information
This instruction manual consists of the following chapters:
1 . GENERAL INFORMATION Outlines this equipment for the user
who ---uses it for the first time.
2. IDENTIFICATION OF EACH PART Describes the function of
each part of
the panels and how to use it.
3. SAMPLE KEY OPERATIONS
Chapter 3 examples simple key operations
4. STARTING OPERATION to help the user learn how to use this
--1---equipment.
5. GPIB INTERFACE Explains how to fully remote control {5.9
Sample Programs) this equipment using a personal or
_|--system computer.
6. BCD OUTPUT (OPTOl) Describes option 01. Option 01 is
/R6551 only) effective on R6551 only.
7. SPECIFICATION, OPTIONS,
AND Accessories
8. CHECKING AND CALIBRATION Helps the user to troubleshoot
with this
... equipment
and make calibration.
9. DESCRIPTION OF R6551 / Summarizes the operation of this
R6551EMC OPERATION equipment.
Type manuel:
Manuel de l'utilisateur
Pages:
212
Taille:
6.15 Mbytes (6452860 Bytes)
Langue:
english
Révision:
Manuel-ID:
FOE-8311246D01
Date:
1988 09 30
Qualité:
Document scanné, tous les lisible.
Date de transfert:
2019 01 07
MD5:
dceadcfb977a9d9903fd30047a324bb3
Téléchargements:
551