Informations sur l'appareil:

Sorensen Company DCS 80-13E Compteur de fréquence
Fabricant:
Sorensen Company
Modèle: DCS 80-13E
Date: 1998
Catégorie: Mètres
Groupe: Compteur de fréquence
Description:
Information:
                                    DCS Series power supplies are 1000W supplies designed to
provide highly stable, continuously variable output voltage
and current for a broad range of development, system and
burn-in applications. The series consists of ten models
designated by the DCS prefix, followed by the output voltage
and current ratings. For example, the model number DCS
60-18E indicates that the unit is rated at 0-60 Vdc and 0-18
Amps while a model DCS 20-50E is rated at 0-20 Vdc and
0-50 Amps. The DCS Series employs high frequency switching
regulator technology to achieve high power density
and small package size.

· Ten models with voltage ranges from 0-8 Vdc to 0-600 Vdc
and current outputs from 1.7A to 125A.
· 115/230 Vac selectable input voltage, 50-60 Hz single
phase, Installation Category II. For Indoor Use.
· Simultaneous digital display of both voltage and current.
· Ten turn potentiometer voltage and current controls permit
high resolution setting of the output voltage
and current from zero to the rated output.
· Automatic mode crossover into current or voltage mode.
· Flexible output configuration: multiple units can be
connected in parallel or series to provide increased
current or voltage.
· High frequency switching technology allows high power
density, providing increased power output in a
small, light package.
· Remote sensing to compensate for losses in power leads.
· Adjustable Over-Voltage Protection (OVP)
· External TTL, AC or DC shutdown
· Remote voltage, resistive, current limit and OVP
programming with selectable programming constants.
· External indicator signals for remote monitoring of OVP
status, local/remote programming status,
thermal shutdown, and output voltage and current.
· Optional IEEE-488 Interface for complete remote
programming and readback capability.

Ces manuels sont disponibles pour les équipements ci-dessus :

Type de document: Manuel de l'utilisateur Sorensen-7392-Manual-Page-1-Picture
Nombre de pages: 47
Taille du fichier: 364.25 Kbytes (372997 Bytes)
langue: Anglais
Révision: D
Document ID/Numéro: M360761
Date: 28 avril 1998
qualité: Électronique de documents, numérisation sans, bien lisible.
Chargé sur:
MD5: 010c47ce346fe65164c36d05f74543c3
Téléchargements: 780 depuis 29 novembre 2015
Information:
SECTION 1. FEATURES AND
SPECIFICATIONS ... 
1-1
1.1 DESCRIPTION
 ... 
1-1
1.2 OPERATING
MODES ... 
1-1
1.3 Power supply
FEATURES ... 
1-1
1.4 SPECIFICATIONS
 ... 
1-2
1.4.1 Electrical
Specifications ... 
1-2
1.4.2 Mechanical
Specifications ... 
1-3
SECTION 2. INSTALLATION AND OPERATING
INSTRUCTIONS ... 
2-1
2.1
GENERAL ... 
2-1
2.2 INITIAL INSPECTION
 ... 
2-1
2.3 INSTALLATION
 ... 
2-1
2.3.1 Input Voltage Selection
 ... 
2-1
2.3.2 Input Line
Impedance ... 
2-2
2.3.3 Ventilation Requirements
 ... 
2-2
2.3.4 Output Voltage Biasing
 ... 
2-2
2.3.5 Rack
Mounting ... 
2-2
2.4 INITIAL FUNCTIONAL
TESTS ... 
2-4
2.5 CONTROLS, CONNECTORS, AND
INDICATORS ... 
2-5
2.5.1 Front Panel
 ... 
2-5
2.5.2 Rear Panel
 ... 
2-5
2.6 STANDARD OPERATION
 ... 
2-7
2.6.1 Load Conductor
Ratings ... 
2-7
2.6.2 Load Connection and
Grounding ... 
2-7
2.6.3 Inductive
Loads ... 
2-7
2.6.4 Remote Sensing
 ... 
2-8
2.6.5 Negative Output Operation
 ... 
2-8
2.7 SINGLE SUPPLY OPERATION (LOCAL
MODE) ... 
2-9
2.8 MULTIPLE SUPPLIES
 ... 
2-9
2.8.1 Series Operation
 ... 
2-10
2.8.2 Parallel Operation
 ... 
2-10
2.8.3 Split Supply Operation
 ... 
2-10
2.9 OVER VOLTAGE PROTECTION (OVP)
 ... 
2-10
2.9.1 Front Panel OVP Operation
 ... 
2-11
2.9.2 Remote Programming of OVP With External Voltage
Sources
 ... 
2-11
2.9.3 Remote Programming of OVP with an External Resistance
 ... 
2-13
2.9.4 Remote Programming of OVP with External Current
Sources ... 
2-14
2.9.5 Remote OVP
Sensing ... 
2-15
2.10 REMOTE ON/OFF
 ... 
2-15
2.10.1 Remote ON/OFF by Contact
Closure ... 
2-15
2.11 REMOTE PROGRAMMING OF OUTPUT VOLTAGE AND CURRENT
LIMIT ... 
2-16
2.11.1 Programming With External Voltage
Sources ... 
2-16
2.11.2 Programming With an External
Resistance ... 
2-18
2.11.3 Programming With an External Current source
 ... 
2-20
2.12 REMOTE MONITORING AND STATUS
INDICATORS ... 
2-21
SECTION 3. THEORY OF
OPERATION ... 3-1
3.1 POWER CIRCUIT (A2 ASSEMBLY)
 ... 3-1
3.1.1 Basic Off-Line Switching Regulator Theory
 ... 3-1
3.1.2 Simplified Full Bridge Converter Theory
 ... 3-1
3.1.3 Detailed Circuit
Description ... 3-3
3.2 METER CIRCUIT (A1 ASSEMBLY)
 ... 3-8
3.2.1
Voltmeter ... 3-8
3.2.2 Current
Meter ... 3-8
SECTION 4. MAINTENANCE, TROUBLESHOOTING, AND CALIBRATION
 ... 4-1
4.1 GENERAL
 ... 4-1
4.2 PERIODIC
SERVICE ... 4-1
4.3
TROUBLESHOOTING ... 4-1
4.3.1 Preliminary Checks
 ... 4-1
4.3.2 Internal Troubleshooting
 ... 4-2
4.4
CALIBRATION ... 4-2
SECTION 5. PARTS LISTS
 ... 5-1
5.1 GENERAL
 ... 5-1
5.2 PARTS ORDERING
 ... 5-1
5.3 PARTS
LISTS ... 5-1
SECTION 6. DRAWINGS AND
SCHEMATICS ... 6-1
6.1 GENERAL
 ... 6-1
6.2 DRAWINGS AND SCHEMATICS  NOT INCLUDED!
Sorensen-7392-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!