The Model 711A Power Supply is a general-purpose low-power
dc and ac voltage supply particularly suited to powering
experimental setups,
By means of the facilities provided by the Model 711A the
following voltages are made available at the output
terminals on the control panel:
Unregulated ac:
6. 3 volts, 3 amperes maximum load current (two supplies) or
6. 3 volts, 6 amperes maximum load current (one supply) or
12.6 volts, 3 amperes maximum load current (one supply,
tapped at 6. 3V).
Regulated dc:
0 to 500 volts, continuously variable; maximum output load
current, 100 ma.
NOTE: Insulation within the Model 711A permits operating the
dc output voltage as much as 500 volts from chassis ground
so that two Model 711A Power Supplies may be operated in
series to obtain 1000 volts dc output while each instrument
chassis remains at ground potential.
The dc output of the Model 711A has high stability; for line
voltage variations within rated limits, the
level of the regulated output will vary less than 0. 5% or 1
volt (whichever is greater), and from no load to full load
the level of the output will vary less than 0.5% or 1 volt
(whichever is greater). Ripple will be less than 0. 001 volt.
While the internal impedance of the Model 711A will vary
both with the dc load current and the frequency of any
reflections from the equipment being powered, the internal
impedance of the Model 711A will be less than 10 ohms with
any load current and at any frequency up to a few megacycles.
The dc output is continuously monitored by two meters, a
voltmeter and a milliammeter. A low and high range are
provided for each meter so that low values of voltage and
current may be read accurately.
The Power Supply is protected from input or output overload
by (1) a fuse in the line-voltage input circuit and (2) a
relay, in the main positive bus, which operates at overload
current to interrupt conduction through the regulator.
1 Manuel
Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
45
Taille:
4,8 Mio
Langue:
anglais
Révision:
Manuel-ID:
00198-3
Date:
juillet 1965
Qualité:
Document scanné, tout est lisible.
Date de téléchargement:
30 décembre 2017
MD5:
2bfaf332-54a1-d3ef-2246-b035e708f612
Information
I GENERAL DESCRIPTION...
1-1 General Description...
1-2 Inspection ...
1-3 Power Cable . ... .
1-4 230-Volt Operation...
II OPERATING INSTRUCTIONS...
2-1 Controls and Terminals . . . ,
2-2 Operating Procedure...
2-3 Output Options...
III CIRCUIT DESCRIPTION...
3-1 General Description...
3-2 Input...
3-3 Regulation...
3-4 Setting of Output Voltage Level .
3-5 Overload Relay...
IV MAINTENANCE...
4-1 General ...
4-2 Cover Removal...
4-3 Tube Replacement...
4-4 Replacement of Electrolytic
Capacitors...
4-5 Replacement of Variable
4-6 Resistors... Replacement of Rectifiers. . .
4-7 Meter Zero Adjustment . . . .
4-8 Power Transformer Primary
Connections...
4-9 4-10 Troubleshooting Chart . . . . Trouble
Localization . . . . .
V REPLACEABLE PARTS...
5-1 Introduction...
5-2 Ordering Information...
5-3 Non-Listed Parts...
Appendix
A CODE LIST OF MANUFACTURERS
B SALES AND SERVICE OFFICES
C MANUAL BACKDATING CHANGES
Téléchargements: