The high performance OS2100 and OS2100R series Oscilloscope main frames provide a bandwidth of
at least 30MHz with high brilliance and readily ac-
cepts all OS2000 series Plug-In modules, The main
frame contains the cathode ray tube with the appro-
priate brilliance and focus controls, power supplies,
main X and Y Amplifier together with a 170nS delay
line and 1kHz Calibrator emiconductors are used
throughout and all power rails are fully stabilised
against power line voltage fluctuations by means of
a constant voltage transformer (CVT). Separate Plug-In modules are used for the X and Y deflection
thereby ensuring maximum versatility.
The cathode ray tube operating at 10kV ensures a
clear bright trace at fast writing speeds. The dis-
play area is 10 x 6cm and a P31 general purpose
phosphor is fitted as standard, with a P7 long per-
sistance phosphor being available as an option.
Graticule illumination, focus and brilliance are pro-
vided as front panel controls with astigmatism and
trace rotation, as front panel pre-set controls.
A 170nS delay line in the Y deflection system en-
ables the leading edge of the triggering waveform
to be observed. Dual trace display is achieved by
chopped/alternate sweep methods; the beam switch
circuit being integral with the dual trace Y Plug-In and the operating mode selected automatically by
the position of the time base range switch. The X Amplifier is normally driven from the time-base Plug-In module and is capable of providing sweep
speeds of up to 20nS/em. Alternatively, using the Oscilloscope in the XY mode a horizontal bandwidth
of at least 200kHz is achievable, Full Z MODULA-
TION facilities are provided; via a socket on the
rear panel,
A noteable feature of the main frame is the use of
a constant voltage transformer to stabilize the
power rails. Apart from providing adjustment-free
operation over the line input range 95 to 130V or
190-260V, its transient suppressing capabilities
ensures faultless triggering in the presence of sub-
stantial power line noise. It should be noted, how-
ever, that the line frequency should be specified
when ordering.
The construction of the main frame and the availa-
bility of blank Plug-In modules makes the OS2100MF
ideally suited for special purpose applications. |
1 Manuel
Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
30
Taille:
16,7 Mio
Langue:
anglais
Révision:
Manuel-ID:
Date:
Qualité:
Document scanné, tout est lisible.
Date de téléchargement:
29 janvier 2023
MD5:
41ce3449-736a-d24f-db68-4bf7bf638c41
Téléchargements:
323
Télécharger
gould--os2100--service-user--ID14058.pdf