Information

The General Resistance D A S is a versatile laboratory Instrument that provides high precision and stability In a compact portable unit. It Is so designed and constructed as to be essentially Independent of ambient temperature and loading within the instrument ratings. The DAS has the following basic functional modules? 1 * A chopper-stabilized operational Amplifier 2. A highly stable reference source. 3. A Kelvin Varley potential divider. The D A S is contained in a package whose envelope Is: Series 40 & 50: 6-7/16" h x 6 " w x 7" d Series 60, 70 & 80? 7" h x 8" w x 10-5/16" d The D A S 50 and 80 have built-in constant-current operation while the DAS 40 60, and 70 can be used with an inexpensive adaptor to provide constant-current operation. Remote sensing terminals are provided to furnish the calibrated voltage at locations distant from the Dial-A-Source output terminals. The remote sensing capability automatically compensates for the voltage drop in the connecting cables.

afficher plus

1 Manuel

Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
39
Taille:
25,4 Mio
Langue:
anglais
Révision:
Manuel-ID:
Date:
janvier 1977
Qualité:
Document scanné, lecture en partie mauvaise, en partie illisible.
Date de téléchargement:
16 août 2017
MD5:
b4bb51b1-4a49-ff8f-342c-bb4b32f2d688

Information

Table of contents m List of illustrations iii Warranty 1.0 Introduction and description 1 . 1 Genera I lo2 Unit specifications 2.0 In i t i a I se t = up 2.1 Unpacking and inspection 2.2 In i t i a I tu rn = on 3.0 Description of operating controls 3 . 0 o 1 Power switch 3.0.2 Range switch 3.0.3 Polarity switch 3.0.4 Voltage decade switches 8.0.5 Output {function switch 3.0.6 Current limit control 3.0.7 Constant-=curp®nt selection 3.1 Calibration controls 3.1.1 Reference calibration 3.1.2 Amplifier zero^set 3.2 Operating instructions 3.2.1 Power 3.2.2 Warmup 3.2.3 Range 3.2.4 Polarity 3.2 ,5 Output voltage 3.2.6 Remote sensing 3.2.7 Load impedance limits 3.2.8 Constant current operation 3.2.9 Current limit control 3.2.10 Optional low nols© attenuator (LNA) 4.0 Maintenance and calibration 4.1 Maintenance and repair 4.2 Operational check 4.3 Calibration 4.3.1 Amplifier zero-set 4.3.2 Reference voltage calibration 4.3.3 Test of Kelvin Varley divider 4 . 3 9 4 Recommended test equipment list

afficher plus

Téléchargements:
2605
Télécharger general-resistance-instruments--das-70--service-user--ID9309.pdf