opweb.de

L'archive de téléchargement gratuit pour les manuels et les guides d'entretien d'entretien


Que recherchez-vous ?


Fluke - 8050A - Multimètre numérique
Fabricant:
Matériels:
8050A
Date:
1979
Catégorie:
Groupe:
Sous-groupe:

Information

1-2. Your John Fluke Model 8050A is a portable bench- type Digital multimeter (DMM) with a 4-1 /2 digit liquid crystal display (LCD). The 8050A has all the following industry-standard features: » Voltage measurements from 10 μ to 1000V dcand 10 mV to 750V true-rms ac. • Current measurements from 10 nA to 2A dc and 10 μΑ to 2A true-rms ac. ® Resistance measurements from 10 mH to 20ΜΏ. The 8050A also has several special measurement features. These special features include the following: • Conductance measurements up to 100,000 Mil. • Voltage measurements in decibels, that can be referenced to 1 of 16 user selected reference impedances. ® Resistance ranges that supply enough voltage to turn on a PN junction to allow diodes and transistors to be tested. • The ability to store any input signal as an offset or relative reference value. • Automatic polarity indication and overrange indication. • Protection from overloads and protection from transients of up to 6 kV, 10 microseconds. • Dual-slope integration a/d conversion to ensure noise-free measurements. • Long term calibration stability (1 year). 1-3. The 8050A is warranted for a period of one year upon shipment of the instrument to the original purchaser. Conditions of the warranty are given at the front of this manual. The 8050A is typically powered from ac line voltages but may be powered by the optional rechargeable battery.

afficher plus

3 Manuels

Manuel d'utilisation avec schémas
Type manuel:
Manuel d'utilisation avec schémas
Pages:
97
Taille:
2,9 Mio
Langue:
anglais
Révision:
2 7/84
Manuel-ID:
530907
Date:
Qualité:
Document scanné, tout est lisible.
Date de téléchargement:
19 février 2009
MD5:
8c0a3ade-3a51-72d5-2d90-ef6687562db8
Téléchargements:
3692
Téléchargements du mois dernier:
3
Télécharger fluke--8050a--user-schematics--ID1437.pdf
Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
104
Taille:
8,5 Mio
Langue:
anglais
Révision:
2
Manuel-ID:
530907
Date:
Qualité:
Document scanné, tout est lisible.
Date de téléchargement:
27 janvier 2016
MD5:
9046d898-8f51-2b66-5539-42430b1b1d33

Information

1 INTRODUCTION AND SPECIFICATIONS 1-1 1-1. INTRODUCTION 1-1 1-4. OPTIONS AND Accessories 1-1 1-5. SPECIFICATIONS ... 1-1 2 OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SETTING UP YOUR INSTRUMENT ... 2-1 2-4. Unpacking ... 2-1 2-8. AC Line Voltage Requirements 2-1 2-10. Fuse Replacement 2-1 2-13. FRONT PANEL FEATURES 2-2 2-15. Display 2-2 2-18. SIGNAL INPUT LIMITS 2-2 2-20. OPERATING TECHNIQUES 2-3 2-22. AC/DC Voltage (V) 2-3 2-24. AC/ DC Current (mA) 2-3 2-26. Resistance (Ω) 2-7 2-28. Conductance (S = 1Ω) 2-7 2-30. Diode Test 2-7 2-32. Relative (RELATIVE) 2-7 2-36. Decibel (dB) 2-11 2-38. INITIAL CHECKOUT PROCEDURE ... 2-12 2-41. APPLICATIONS 2-12 2-43. DC Voltage Measurement 2-12 2-51. Current Measurement 2-13 2-56. Resistance Measurement 2-13 2-62. Conductance Measurement 2-14 2-80. Relative Measurement 2-16 2-84. AC Voltage and Current Measurement... 2-16 3 THEORY OF OPERATION... 3-1 3-1. INTRODUCTION ... 3-1 3-3. FUNCTIONAL DESCRIPTION 3-1 TITLE PAGE 3-7. A/D Converter 3-1 3-18. Microcomputer ...3-2 3-20. Signal Conditioning ...3-6 3-31. True-RMS Converter 3-8 3-38. Touch-Hold Circuit ...3-8 3-40. Voltage Protection ...3-8 3-43. Current Protection ...3-8 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-4. SERVICE INFORMATION ... 4-1 4-7. GENERAL INFORMATION ... 4-1 4-9. Interior Access... 4-1 4-24. dB Reference Impedance Power-Up Setting... 4-4 4-26. Cleaning ... 4-5 4-28. PERFORMANCE TESTS ... 4-5 4-30. Initial Procedures ... 4-5 4-32. Display Test... 4-5 4-34. Linear Voltage Test ... 4-6 4-36. dB Voltage Test... 4-6 4-38. Current Test... 4-7 4-40. Resistance and Conductance Tests... 4-7 4-42. CALIBRATION ADJUSTMENTS ... 4-8 4-44. DC Calibration ... 4-8 4-46. AC Calibration ... 4-8 4-48. Jumper Selection... 4-8 4-57. TROUBLESHOOTING ... 4-12 5 LIST OF REPLACEABLE PARTS ... 5-1 TABLE OF CONTENTS ... 5-1 5-1. INTRODUCTION ... 5-2 5-3. PARTS ORDERING INFORMATION ... 5-2 6 OPTIONS AND Accessories 6-1 TABLE OF CONTENTS ... 6-1 INTRODUCTION ... 6-2 Accessories 600-1 OPTIONS ... 601-1 7 SCHEMATIC DIAGRAMS ... 7-1 TABLE OF CONTENTS ... 7-1 APPENDIX A ... A-1

afficher plus

Téléchargements:
1130
Téléchargements du mois dernier:
10
Télécharger fluke--8050a--service-user--ID7619.pdf
Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
106
Taille:
5,1 Mio
Langue:
anglais
Révision:
2
Manuel-ID:
530907
Date:
Qualité:
Document scanné, tout est lisible.
Date de téléchargement:
13 février 2016
MD5:
645b1f5f-0f6c-33dd-dc5f-e37e20c5466f

Information

1 2 TITLE PAGE INTRODUCTION AND SPECIFICATIONS ... 1-1 l-l. INTRODUCTION . I-4. OPTIONS AND ACCESi I-5. SPECIFICATIONS ... 1-1 SORIES... 1-1 ... 1-1 OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SETTING UP YOUR INSTRUMENT ... 2-1 2-4. Unpacking ... 2-1 2-8. AC Line Voltage Requirements ... 2-1 2-10. Fuse Replacement... 2-1 2-13. FRONT PANEL FEATURES... 2-2 2-15. Display ... 2-2 2-18. SIGNAL INPUT LIMITS ... 2-2 2-20. OPERATING TECHNIQUES... 2-3 2-22. AC/DC Voltage (V) ... 2-3 2-24. AC/DC Current (mA) ... 2-3 2-26. Resistance (Ω) ... 2-7 2-28. Conductance (S = IΩ)... 2-7 2-30. Diode Test ... 2-7 2-32. Relative (RELATIVE) ... 2-7 2-36. Decibel (dB)... 2-11 2-38. INITIAL CHECKOUT PROCEDURE ... 2-12 2-41. APPLICATIONS ... 2-12 2-43. DC Voltage Measurement ...,... 2-12 2-51. Current Measurement ... 2-13 2-56. Resistance Measurement ... 2-13 2-62. Conductance Measurement ... 2-14 2-80. Relative Measurement ... 2-16 2-84. AC Voltage and Current Measurement... 2-16 THEORY OF OPERATION... 3-1 3-1. INTRODUCTION ... 3-1 3-3. FUNCTIONAL DESCRIPTION ... 3-1 3-5. CIRCUIT DESCRIPTION... 3-1 TITLE PAGE 3-7. A/D Converter 3-1 3-18. Microcomputer ...3-2 3-20. Signal Conditioning ...3-6 3-31. True-RMS Converter 3-8 3-38. Touch-Hold Circuit ...3-8 3-40, Voltage Protection ...3-8 3-43. Current Protection ...3-8 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-4. SERVICE INFORMATION ... 4-1 4-7. GENERAL INFORMATION ... 4-1 4-9. Interior Access... 4-1 4-24. dB Reference Impedance Power-Up Setting... 4-4 4-26. Cleaning ... 4-5 4-28. PERFORMANCE TESTS ... 4-5 4-30. Initial Procedures ... 4-5 4-32. Display Test... 4-5 4-34. Linear Voltage Test ...*... 4-6 4-36. dB Voltage Test... 4-6 4-38. Current Test... 4-7 4-40. Resistance and Conductance Tests ... 4-7 4-42. CALIBRATION ADJUSTMENTS ... 4-8 4-44. DC Calibration ... ... 4-8 4-46. AC Calibration ... ... 4-8 4-48. Jumper Selection... 4-8 4-57. TROUBLESHOOTING ... 4-12 5 LIST OF REPLACEABLE PARTS ... 5-1 TABLE OF CONTENTS ... 5-1 5-1. INTRODUCTION ... 5-2 5-3. PARTS ORDERING INFORMATION ... 5-2 6 OPTIONS AND Accessories 6-1 TABLE OF CONTENTS ... 6-1 INTRODUCTION ... 6-2 Accessories 600-1 OPTIONS ... 601-1 7 SCHEMATIC DIAGRAMS ... 7-1 TABLE OF CONTENTS ... 7-1 APPENDIX A ... A-1

afficher plus

Téléchargements:
2177
Téléchargements du mois dernier:
13
Télécharger fluke--8050a--service-user--ID7727.pdf