The Model 8040A Multimeter provides the accuracy and
portability required in today’s field service work. A
slide-out sunshade protects the 4/2 digit LED display from
glare when operating the 8040A in adverse lighting
conditions. The small size and battery power add to the
portability; yet the fold-away stand allows the instrument
to be positioned at a convenient angle for bench top use.
The 8040A offers 20,000 count resolution in all five
functions which provides measurement resolution to 0.01 ohms
on the 200 ohm range and 10 microvolts on the 200 millivolt
range. AC voltage and current measurements are made using
true rms conversion techniques for improved accuracy in
communications and industrial control applications.
Several Accessories are available for use with the 8040A to
expand its’ capabilities. A list of these Accessories is
provided in Table l-1 while more detail about each one is
provided in Section 6.
Note that two of the Accessories the 80T-150 temperature Probe and A8l battery charger/eliminator, are configured at
the factory for particular applications. Insure that the
correct form of the model number is used when ordering
either of these Accessories
1 Manuel
Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
61
Taille:
6,5 Mio
Langue:
anglais
Révision:
Manuel-ID:
427138
Date:
octobre 1976
Qualité:
Document scanné, tout est lisible.
Date de téléchargement:
20 janvier 2018
MD5:
3e631fa2-036c-f674-0e97-99e3974ee242
Information
1 INTRODUCTION AND SPECIFICATIONS...
1-1. INTRODUCTION...
1-6. SPECIFICATIONS...
2 OPERATING INSTRUCTIONS ...
2-1. INTRODUCTION...
2-3. SHIPPING INFORMATION...
2-6. INPUT POWER...
2-8. OPERATING FEATURES...
2-10. OPERATING NOTES...
2-12. Fuse Replacement...
2-14. Overrange Indication ...
2-16. Input Overload Protection/l ...
2-18. ASSEMBLY AND INITIAL OPERATION...
2-22. FUNCTION SELECTION EXAMPLES...
3 THEORY OF OPERATION...
3-1. INTRODUCTION...
3-3. OVERALL FUNCTIONAL DESCRIPTION...
3-4. Introduction...
3-6. Analog Circuits...
3-8. Digital Circuits...
3-10. CIRCUIT DESCRIPTION...
3-11. Introduction...
3-13. Input Divider...
3-15. Current Shunts...
3-17. Buffer...
3-19. A/D Reference...
3-26. Ohms Voltage Source 3-28. RMS Converter 3-33. A/D Converter 3-35. Timing and Control...
3-38. Display...
4
MAINTENANCE...
4-1. INTRODUCTION...
4-4. GENERAL MAINTENANCE...
4-5. Access
Information...
4-7. Cleaning...
4-9. Fuse Replacement...
4-11. PERFORMANCE CHECK ...
4-13. DC
Volts...
4-15. AC
Volts...
4-17. Resistance
Measurements...
4-19. Direct
Current...
4-21. Alternating
Current...
4-23. CALIBRATION...
4-26. Required Method for Votlage Source
Connection...
4-29. TROUBLESHOOTING ...
5 LIST OF REPLACEABLE
PARTS...
5-1. INTRODUCTION...
5-4. HOW TO OBTAIN PARTS ...
5-7. USE CODE EFFECTIVITY LIST...
6 OPTIONS & ACCESSORY INFORMATION...
6-1. INTRODUCTION...
6-3. RECHARGEABLE BATTERY PACK 8040A 7005...
6-4.
Introduction...
6-6. Operation...
6-8. BATTERY COVER KIT 8040A 7004 ...
6-10. BATTERY COVER 8040A 7007 ...
6-12. CARRYING CASE (C88)...
6-14. BATTERY CHARGER/ELIMINATOR...
6-16. TEMPERATURE Probe (80T-150)...
6-17.
Introduction...
6-20. Operating
Notes...
6-25. Operating
Instructions...
6-27. DELUXE TEST LEAD KIT(A80)...
6-29. CURRENT TRANSFORMER, CLAMP-ON (801-600)...
6-30.
Introduction...
6-32.
Operation...
6-34. HIGH VOLTAGE Probe (80F-5) ...
6-35.
Introduction...
6-39.
Cleaning...
6-41.
Calibration...
6-44. HIGH VOLTAGE Probe (80F-15) ...
6-45.
Introduction...
6-49.
Cleaning...
6-51.
Calibration...
6-54. HIGH VOLTAGE Probe 80K-40 6-55.
Introduction...
6-58. HIGH FREQUENCY Probe (81RF)...
6-59.
Introduction...
6-61. HIGH FREQUENCY Probe 82RF 6-62.
Introduction...
Téléchargements:
889
Télécharger
fluke--8040a--service-user--ID10165.pdf