opweb.de

L'archive de téléchargement gratuit pour les manuels et les guides d'entretien d'entretien


Que recherchez-vous ?


Fluke - 341A - Calibrateur
Fabricant:
Matériels:
341A
Date:
1969
Catégorie:
Groupe:
Sous-groupe:
DC Voltage Calibrator

Information

The Fluke Model 341Ä and Model 343A' DC Voltage Calibrator provide dc voltages of 0 to 1100 volts in three ranges. Voltages are selected by eleven-position decade switches, which provide in-line, digital readout of the instrument output voltage. The Model 341A employs six-dial readout» with 1 ppm resolution, and the Model 343A employs seven-dial readout, with 0.1 ppm resolution. A controlled current limiter, a fixed current limiter, and an electronic crowbar circuit provide protection against instrument malfunction and operator error. Output current or voltage, depending on function desired, are continuously monitored by a front panel meter. The instruments are designed for rack-mount installation, using the mounting brackets supplied, and are equipped with resilient feet and tilt-down bail for field or bench use.

afficher plus

2 Manuels

Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
98
Taille:
8,5 Mio
Langue:
anglais
Révision:
Manuel-ID:
293951
Date:
Qualité:
Document scanné, tout est lisible.
Date de téléchargement:
10 février 2016
MD5:
4dccc19a-b788-5f56-439b-8480d49f98d3

Information

I INTRODUCTION AND SPECIFICATIONS... 1-1 1-1. introduction ... 1-1 1-5. Electrical Specifications... 1-1 1-6. Environmental Specifications... 1-2 1-7. Mechanical Specifications ... 1-3 1-8. General Specifications... 1-3 II OPERATING INSTRUCTIONS... 2-1 2-1. Introduction ... 2-1 2-4. Operating Features. . ... 2-1 2-6. Controls, Terminals and Indicators ... 2-1 2-8. Input Power Requirements ... 2-1 2-10. Preliminary Operation ... 2-1 2-12, AC Line Connections... 2-1 2-14. Sense Connections... 2-1 2-18. Current Limit Operation... 2-5 2-20. Overload Protection... 2-5 2-23. Mechanical Zero Adjustment... 2-5 2-25.. Operation as a Voltage Calibrator 2-5 2-27. Applications ... 2-6 2-29. Operation as a Differential Voltmeter... 2-6 2-31. Operation as a 10 ppm Source... 2-6 III THEORY OF OPERATION... 3-1 3-1. Introduction... 3-1 3-3. Block Diagram Analysis... 3-1 3-12. Circuit Analysis... 3-3 3-13. +15 Volt Reference and Auxiliary Supplies... 3-3 3-16. Chopper-Stabilized Amplifier 3-3 3-20. Series Regulator... 3-3 3-23. Controlled Current Limiter... 3-4 3-27. Negative Voltage Limiter... 3-4 3-29. Sink Supply and Crowbar... 3-4 3-34. Control Circuit... 3-5 3-38. High Voltage Power Supply... 3-6 3-40. Meter Circuit... 3-6 3-42. Beta String... 3-6 IV MAINTENANCE ...4-1 4-i. Introduction ... ...4-i 4-3. Service information ...4-1 4-6. Test Equipment. ...4-1 4-8. General Maintenance ...4-1 4-9, Maintenance Access... . 4-1 4-13. Adjustment Locations ...4-3 4-15. Cleaning...4-4 4“!S. 1 15/230 Volt Conversion...4-5 4-20. Fuse Replacement ... ...4-5 4-22. Lamp Replacement. ... . 4-5 4-24. Performance Tests...- 4-6 4-26. Line Regulation. ...4-6 4-28. Load Regulation...4-6 4-30, Ripple ...4-7 4-32. Output Voltage Accuracy...4-8 4-36. Troubleshooting ...4-8 4-39. Test Point Resistance Check...4-8 4-41. Standby Test...4-8 4-43. Auxiliary Supply Voltages...4-9 4-45. Power-On Test...440 4-47. Chopper Amplifier 4-11 4-49. Series Regulator ...4-11 4-51. Controlled Current Limiter ...4-12 4-53. Crowbar...4-12 4-55. High Voltage Power Supply 4-12 4-57. Beta String ... . 4-13 4-59. Pane! Meter ...4-13 4-61. Model 341A Calibration ...4-14 4-63. Preliminary Operations... 4-14 4-64. Reference Voltage Adjustment. ...4-14 4-65. Zero Output Adjustments ...4-14 4-66. Beta String Linearity Adjustments ... 4-14 4-67. Range Adjustments . ...4-14 4-68. Calibration Verification ...4-15 4-70. Model 343A Preliminary Calibration...4-15 4-72. Preliminary Operations ...'4-15 4-73. Reference Voltage Adjustment ... : 4-16 4-74. Zero Output Adjustments...4-16 4-75. Beta String Linearity Adjustments...4-16 4-76, Temperature Stabilization...4-17 4-77. Model 343A Final Calibration ...4-17 4-79. Zero Output Adjustments...4-17 4-80. Beta String Linearity Adjustments...4-17 4-83. Range Adjustments...4-19 4-84, Calibration Verifications ...4-20 V LIST OF REPLACEABLE PARTS ...5-1 5-1. Introduction ... . 5-1 5-3. Column Description...5-1. 5-5. How To Obtain Parts ...5-2 5-8. List of Abbreviations ...5-2 5-9. Serial Number Effectivity ...5-45 7 GENERAL INFORMATION... · ?-l 8 SCHEMATIC DIAGRAMS...8-1

afficher plus

Téléchargements:
2171
Téléchargements du mois dernier:
9
Télécharger fluke--341a--service-user--ID7709.pdf
Manuel d'entretien et d'utilisation
Type manuel:
Manuel d'entretien et d'utilisation
Pages:
100
Taille:
4,2 Mio
Langue:
anglais
Révision:
Manuel-ID:
Date:
avril 1973
Qualité:
Document scanné, lecture en partie mauvaise, en partie illisible.
Date de téléchargement:
9 janvier 2025
MD5:
f8be6e55-5d8e-0ad2-34cf-e4afc0c57c04
Téléchargements:
172
Téléchargements du mois dernier:
11
Télécharger fluke--341a--service-user--ID15286.pdf