Tektronix TDS1002 Osciloscopio
Manufacturer:

Image 1 of 1
If you have any other photos or manuals for the
Tektronix TDS1002 you can upload the files here .
Model:
TDS1002
Date:
2002
Category:
Group:
Description:
Digital Storage Oscilloscope
Information
TDS1000 and TDS2000 Series Oscilloscopes. Colorful
Performance at a Black and White Price.
The TDS1000 Series and TDS2000 Series digital storage
oscilloscopes deliver an unbeatable combination of superior
performance, unmatched ease-of-use and affordability in an
ultra lightweight, portable package. These new products
extend the performance and ease-of-use features in the
former TDS200 Series
the benchmark for low-cost oscilloscopes.
Affordable Digital Performance
With up to 200 MHz bandwidth and 2 GS/s maximum sample rate,
no other color digital storage Oscilloscope offers as much
bandwidth and sample rate for the price. The TDS1000 and
TDS2000 Series oscilloscopes
provide accurate real-time acquisition up to their full
bandwidth. These instruments offer advanced triggering, such
as pulse width trig-
gering and line-selectable video triggering, and 11 standard
automatic measurements on all models. The Fast Fourier
Transform (FFT) math function allows the user to analyze,
characterize and troubleshoot circuits by viewing frequency
and signal strength (standard on all models).
Simple User Interface
The simple user Interface makes these instruments easy to
use, reducing learning time and increasing efficiency.
Classic, analog-style controls provide instant, front-panel
access to the most frequently used functions. The autoset
function automatically detects sine waves, square waves and
video signals, and provides readouts of relevant
measurements. This function also allows the user to select
additional views of the signal, such as rising and falling
edges, video lines and fields, and FFT. The Probe check
wizard aids the user in setting the attenuation factor and
compensating the Probe. The context-sensitive help menu with
indexed and hyper-linked topics allows the user to
selectively learn about the operation of any Oscilloscope
function. The color LCD display on the TDS2000 Series models
dedicates a different color for each trace and its
associated readouts to simplify viewing complex signals on
multiple channels.
Features & Benefits
60 MHz, 100 MHz and 200 MHz Bandwidths
Sample Rates up to 2 GS/s
2 or 4 Channels
Color or Monochrome LCD Display
Autoset Menu with Waveform Selection
Probe Check Wizard To Ensure Correct Probe Usage
Context-sensitive Help
Dual Time Base
Advanced Triggering
11 Automatic Measurements
Multi-language User Interface
Waveform and Setup
Memories
FFT Standard on All Models
Extended Capabilities Are Provided with Optional TDS2CMA Module,
WaveStarTM Software and Probes
Manual type:
Hoja de datos
Pages:
4
Size:
233.42 Kbytes (239027 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
2002 01 01
Quality:
Documento electrónico, sin análisis, muy bien legible.
Upload date:
2017 12 27
MD5:
9ca5be08143a46c550ec36458aa9c5d7
Downloads:
2937
Manual type:
Manual de servicio
Pages:
138
Size:
2.03 Mbytes (2127399 Bytes)
Language:
english
Revision:
Manual-ID:
071-1076-02
Date:
Quality:
Documento electrónico, sin análisis, muy bien legible.
Upload date:
2019 09 28
MD5:
c8a232f598b29fb39efb90c32e6d4abf
Downloads:
3455
Information
General Safety Summary ... .
Service Safety Summary ... .
Environmental Considerations ... .
Preface ... .
Related Manuals ... .
Specifications
Certifications and Compliances ... .
Installation ...
Power Cord ... .
Security Loop ... .
Extension Modules ... .
Functional Check ... .
Self Calibration ... .
Default Setup ... .
Main Board ... .
Acquisition System ... .
Processing and Display System ... .
Input Signal Interface ... .
Probe Compensation ... .
External Trigger ... .
Main Board Power ... .
Power supply ... .
Display Module ... .
Front Panel ... .
Two-Channel Oscilloscopes ... .
Four-Channel Oscilloscopes ... .
LEDs ... .
Extension Modules ... .
Required Equipment ... .
Test Record ... .
Performance Verification Procedures ... .
Self Test ... .
Self Calibration ... .
Check DC Gain Accuracy ... .
Check Bandwidth ... .
Check Sample Rate and Delay Time Accuracy ... .
Check Edge Trigger Sensitivity ... .
Check External Edge Trigger Sensitivity ... .
Required Equipment ... .
Adjustment Procedure ... .
Enable the Service Menu ... .
Adjustment Procedure ... .
Preparation ... .
Preventing ESD ... .
Inspection and Cleaning ... .
General Care ... .
Inspection and Cleaning Procedures ... .
Removal and Installation Procedures ... .
Preparation ... .
List of Modules ... .
Summary of Procedures ... .
Required Tools ... .
Rear Feet ... .
Flip Feet ... .
Front-Panel Knobs ... .
Power Button ... .
Rear Case ... .
Front Feet ... .
Power supply Module ... .
Internal Assembly ... .
Display Cable ... .
Front-Panel Cable ... .
Main Board Module ... .
Display Module ... .
Front-Panel Module ... .
Keypad ... .
Front Case ... .
Troubleshooting ... .
Adjustment After Repair ... .
Required Tools and Equipment ... .
Troubleshooting Tree ... .
Probe COMP Output ... .
Troubleshooting the Power supply ... .
Troubleshooting the Display ... .
Troubleshooting the Backlight ... .
Troubleshooting the Front Panel ... .
Troubleshooting the Main Board ... .
Running Diagnostics ... .
Troubleshooting Input Connections ... .
Using the Error Log ... .
Repackaging Instructions ... .
Packaging ... .
Storage ... .
Parts Ordering Information ... .
Module Servicing ... .
Using the Replaceable Parts List ... .
Abbreviations ... .
Mfr. Code to Manufacturer Cross Index ... .