Fluke 8600A Multímetro digital
Fabricante:
Modelo:
8600A
Fecha:
1974
Categoría:
Grupo:
Descripción:

Información

The Model 8600A is a compact and light-weight digital multimeter (DMM). It features a 4% digit display, push-button selection of range and function, auto polarity, self locating decimal point, self zeroing to eliminate offset uncertainties, and overload protection for all ranges. Autoranging can be selected when the ac volts, dc volts or kiloohms functions are selected. Several options and Accessories for the 8600A are available (see Section 6). Push-button controls allow the selection of five ac and dc voltage ranges, five ac and dc current ranges, and six resistance ranges. The measurement capabilities of the 8600A range from 10 microvolts to 1199.9 volts ac and dc, 10 nanoamperes to 1.9999 amperes ac and dc, and 10 milliohms to 19.999 megohms. The front-panel readout features a 4% digit display using light emitting diodes (LED’s). The display includes a self locating decimal point and a + or - polarity indicator. Full-scale readout is 19999 for all ranges and functions except the 1200 volt ac and dc range, which is 11999. A blinking 18888 readout indicates that the 8600A is being operated in an overload condition and provides a test for all segments in the display. Front panel input connectors are banana type and provide separate connections for current, and volt-ohm inputs. Both the current and volt-ohm inputs are referenced to a common input which is isolated from earth ground and can operate at a potential of up to ±1000V dc or peak V ac with reference to earth ground. The overload features of the 8600A include a fused current input and an overvoltage protected volt-ohm input. This protection applies for any function and range selected. 1-7. Several options and Accessories are available for use with the 8600A,

ver más

Manual de servicio
Type manuel:
Manual de servicio
Páginas:
108
Tamaño:
5.11 Mbytes (5357499 Bytes)
Idioma:
english
Revisión:
3
Manuel-ID:
391409
Fecha:
1977 01 01
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2018 01 21
MD5:
56418a02bc1cd92935c24f9aaf203be4
Descargas:
957

Información

1 INTRODUCTION AND SPECIFICATIONS ... 1-1 1-1. INTRODUCTION ... 1-1 1-9. SPECIFICATIONS ... 1-2 2 OPERATING INSTRUCTIONS ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SHIPPING INFORMATION ... 2-1 2-6. INPUT POWER ... 2-1 2-9. RACK INSTALLATION ... 2-1 2-11. OPERATING FEATURES ... 2-1 2-13. OPERATING NOTES ... 2-3 2-15. Option Information ... 2-3 2-17. Fuses ... 2-3 2-19. Overrange Indication ... 2-3 2-21. Input Overload Protection /i ... 2-3 2-23. Autoranging ... 2-3 2-25. OPERATION ... 24 3 THEORY OF OPERATION ... 3-1 3-1. INTRODUCTION ... 3-1 3-3. OVERALL FUNCTIONAL DESCRIPTION ... 3-1 34. Introduction ... 3-1 3-6. Input Signal Conditioners ... 3-1 3-12. A/D Converter ... 3-2 3-15. Control and Display ... 3-2 3-18. Data Output Unit (DOU) ... 3-3 3-20. CIRCUIT DESCRIPTION ... 3-3 3-22. Input Signal Conditioners ... 3-3 3-37. A/D Converter ... 3-6 342. Control and Display ... 3-8 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-3. SERVICE INFORMATION ... 4-1 4-6. GENERAL MAINTENANCE ... 4-2 4-7. Access/Disassembly ... 4-2 4-10. Cleaning ... 4-2 4-12. Fuse Replacement ... 4-2 4-14. PERFORMANCE TESTS ... 4-2 4-16. DC Voltage Test ... 4-2 4-18. Ohms Test ... 4-2 4-20. DC Current Test ... 4-3 4-22. AC Voltage Test ... 4-3 4-24. CALIBRATION ... 4-3 4-25. Introduction ... 4-3 4-27. DC Volts Calibration ... 4-3 4-29. Ohms Calibration ... 4-5 4-31. AC Volts Calibration ... 4-5 4-33. TROUBLESHOOTING ... 4-5 4-35. Initial Troubleshooting ... 4-6 4-38. Power supply Checks ... 4-6 4-40. Fault Area Isolation ... 4-7 5 LIST OF REPLACEABLE PARTS ... 5-1 5-1. INTRODUCTION ... 5-2 5-4. HOW TO OBTAIN PARTS ... 5-2 5-7. USE CODE EFFECTIVITY LIST ... 5-2 6 OPTIONS AND ACCESSORY INFORMATION ... 6-1 6-1. INTRODUCTION ... 6-1 6-3. CARRY CASE (C80) ... 6-1 6-5. CARRYING CASE (C86) ... 6-1 6-7. FRONT PANEL DUST COVER (M00-100-714) ... 6-1 6-9. RACK MOUNTING KITS ... 6-1 6-10. Introduction ... 6-1 6-12. Installation Procedure ... 6-2 6-16. DELUXE TEST LEAD KIT (A80) ... 6-2 6-18. CURRENT Probe, CLAMP-ON (801-600) ... 64 6-19. Introduction ... 64 6-21. Operation ... 64 6-23. HIGH VOLTAGE Probe (80K40) ... 6-5 6-24. Introduction ... 6-5 6-26. Specifications ... 6-5 6-27. Operation ... 6-5 6-29. HIGH FREQUENCY Probe (80RF-1) ... 6-6 6-30. Introduction ... 6-6 6-32. Specifications ... 6-6 6-33. Operating Notes ... 6-6 6-36. Operation ... 6-6 6-38. Theory of Operation ... 6-7 6-41. Maintenance ... 6-7 6-50. HIGH FREQUENCY Probe (81RF) ... 6-9 6-51. Introduction ... 6-9 6-53. Specifications ... 6-9 6-54. Operation ... 6-9 6-56. TEMPERATURE Probe (80T-150) ... 6-9 6-59. BATTERY PACK, OPTION-01 ... 6-9 6-60. Introduction ... 6-9 6-62. Specifications ... 6-9 6-64. Operation ... 6-9 6-66. Theory of Operation ... 6-10 6-69. Maintenance ... 6-10 6-80. DATA OUTPUT UNIT (OPTION-02) ... 6-11 6-81. Introduction ... 6-11 6-83 Specifications ... 6-11 6-85 Operation ... 6-11 7 GENERAL INFORMATION ... 7-1 8 SCHEMATIC DIAGRAMS ... 8-1

ver más