Hewlett Packard 3586B LCR Meter
Fabricante:
Modelo:
3586B
Fecha:
1979
Categoría:
Grupo:
Descripción:
Selective Level Meter

Información

The 3586A.B Selective Level Meter is designed for use in the design, manufacture, installation, and maintenance of Frequency Division Multiplex (FDM) systems and for general purpose wave analysis and frequency synthesis. The 3586A is available to meet the needs of C.C.I.T.T. requirements, while the 3586B meets North American (Bell) Standards. The 3586C is a general purpose instrument. The 3586A.B provides the ability to make both carrier frequency measurements to 32.5MHz and voice channel measurements from 50Hz to 100kHz. The Transmission impairments Option 003 allows the user to quickly troubleshoot voice channel problems with phase jitter, noise-with-tone, signal-to-noise-with-tone-ratio, and single level impulse noise measurements, all with one instrument. The capability to make all these transmission impairment measurements combined with both FDM voice channel and carrier frequency measurements is available only on the 3586A.B. Standard models include a 1740Hz psophometric or 2000Hz C-message equivalent noise Filter, or weighted noise measurements can be made directly with the 3100Hz channel Filter and noise weighting Filter provided with the Transmission Impairments Option 003. Filter shape factor of < 1.2 provides 60dB carrier and 75dB adjacent channel rejection.

ver más

Manual de servicio
Type manuel:
Manual de servicio
Páginas:
258
Tamaño:
24.89 Mbytes (26096342 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
03586-90002V1
Fecha:
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2013 11 23
MD5:
0cd427becc8abaa881d815836a7e46d2
Descargas:
2189

Información

This manual applies to all instruments. Earlier versions of the 3586A.B/C, however, may differ in design and appearance from the instruments this revision documents directly. Changes that have been made to the instrument and which affect the instrument's documentation are identified by the Delta (A) symbol. The "numbered" A refers the reader to the corresponding numbered A in the backdating section (Section VII) in Volume I of the 3586A.B/C Service Manual. Service Manual Volume I

ver más

Manual de servicio
Type manuel:
Manual de servicio
Páginas:
185
Tamaño:
44.42 Mbytes (46579470 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
03586-90002V2
Fecha:
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2013 11 23
MD5:
137553d35232883d5e2da88fdfcbcf50
Descargas:
2349

Información

Service Manual Volume II This manual applies to all instruments. Earlier versions of the 3586A.B/C, however, may differ in design and appearance from the instruments this revision documents directly. Changes that have been made to the instrument and which affect the instrument's documentation are identified by the Delta (A) symbol. The "numbered" A refers the reader to the corresponding numbered A in the backdating section (Section VII) in Volume I of the 3586A.B/C Service Manual. 8-2. This volume of the Service Manual contains information relative to the maintenance and service of the 3586A.B/C Selective Level Meter. The information presented in this manual is assembled into four major segments: Turn-on Initialization and Milking the Front Panel, Troubleshooting, Detailed Functional (circuit) Description, and Service Groups. Where references are made throughout the manual to a performance test, adjustment procedure, the parts list, or backdating section, refer to Volume I: 3586 Performance Tests, Adjustments, Parts, and Backdating. In order to obtain a minimum of instrument down time and to provide for the greatest amount of troubleshooting efficiency and safety, it is recommended that Safety Considerations (paragraph 8-5), Use Of The Service Manual (paragraph 8-8), and Service Volume Organization (paragraph 8-11) be read before initiating any troubleshooting procedures.

ver más

Manual del usuario
Type manuel:
Manual del usuario
Páginas:
146
Tamaño:
4.26 Mbytes (4470828 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
03586-90012
Fecha:
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2013 11 23
MD5:
49036966b1a619c78917cd8eee76af85
Descargas:
1622

Información

This manual applies to instruments with serial number prefixed 1927A, 192«A, and 1929A.

ver más