Associated Research Incorporated 3030D Test Set
Fabricante:
Modelo:
3030D
Fecha:
2000
Categoría:
Grupo:
Descripción:
GROUND BOND TESTER

Información

KEY FEATURES & BENEFITS OF HYAMP in 1. All parameters for the setups can be adjusted through a simple menu driven program by using front panel keys. The easy to follow setup screens ensure that the operator correctly sets up all test parameters. 2. Tamper proof front panel controls. This makes it possible to limit user access to the setup screens. 3. MilJiohm offset capability. rThe milliohm off set function allows the use of longer test leads and test fixtures without compromising the test results. 4. Storage of up to 5 different test programs. A real benefit for manufacturers that test different products. - This makes it possible to store all the various test parameters required and quickly recall them for each of the different products that needs to be tested 5. Versatile PLC control. Interconnection.of the HYAMP jr. and the Hypot II makes these two instruments a true semi-automated test system. The test system can be configured to test Ground Bond first and then advance to the Dielectric Withstand test and Insulation Resistance tests. 6. Line and load regulation. This system maintains the output voltage to within 1% from no load to full load and over the line voltage range to ensure that test results remain consistent and within safety agency requirements. 7. User selectable output voltage frequencies of 50 or 60 hertz. HYAMP jr. was designed for the global market This feature makes it simple for the user to select the output frequency in the Ground Bond mode so that products can be tested at the same frequency they will be used at 8. Adjustable output current and milliohm trip ranges. This capability makes the HYAMP jr. versatile enough to meet all safety agency specifications for ground bond test requirements. 9. Front panel LCD displays test parameters and results. A front panel LCD allows the operator to monitor the test The display holds the results after a test item failure so that the operator can easily review the test results. 10. PLC remote inputs and outputs. The standard 9 pin interfaces provide outputs for Pass, Fail, and Test in Process, Start Out and Reset Out. Inputs include Test, Reset, and Withstand Processing. 11. Test indicator. An LED located directly over the high current terminal clearly indicates when high current is active to provide maximum operator safety. 12. Withstand processing indicator. The front panel display indicates when the high voltage from the Hypot II is being applied to the item under test for greater operator safety. 13. Software calibration control. HYAMP jr. is calibrated through the front panel keypad. All calibration information is stored in non-volatile memory. This allows HYAMP jr. to be completely calibrated without removing any covers and exposing the technician to hazardous voltages.

ver más

Servicio y Manual del usuario
Type manuel:
Servicio y Manual del usuario
Páginas:
51
Tamaño:
1.83 Mbytes (1916072 Bytes)
Idioma:
english
Revisión:
1.05
Manuel-ID:
37952
Fecha:
2000 11 17
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2017 10 21
MD5:
301372b7b1e5df5c9a441459b289b8fb
Descargas:
486

Información

SECTION I OPERATORS MANUAL.,, ... 1 SAFETY ... 2 INTRODUCTION ... 5 SPECIFICATIONS ... 8 CONTROLS ... 12 INSTALLATION ... 15 QUICK START ... 18 OPERATION ... 22 OPTIONS ... 32 SECTION II SERVICE MANUAL ... 35 CALIBRATION ... 36 PARTS LIST ... 38 SCHEMATICS ... 39

ver más