                                    INTERFACE FEATURES
The Model 40200 RS-449 DTE/DCE Data Interface has the
following features.

•	Enables a FIREBERD mainframe to act as the DTE or DCE with
an appropriate adapter cable.

•	Front panel switches allow control over connector
termination, clock polarity, and timing mode.

•	Allows testing of RS-449-type circuits using serial binary
formatted data up to 15 MHz.
1.3	INTERFACE COMPATIBILITY
The Model 40200 RS-449 DTE/DCE Data Interface is designed in
accordance with the following specifications.

•	EÏA Standard RS-449, General Purpose 37-position and
9-position Interface for Data Terminal Equipment and Data
Circuit-Terminating Equipment Employing Serial Binary Data
Interchange, November 1977.

•	EIA Standard RS-422-A, Electrical Characteristics of
Balanced Voltage Digital Interface Circuits, December 1978.

•	EIA Standard RS-423-A. Electrical Characteristics of
Unbalanced Voltage Digital Interface Circuits, December 1978.

•	CCITIT Recommendation V. 10 (or X.26), Electrical
characteristics for unbalanced double-current interchange
circuits for general use with integrated circuit equipment
in the field of data communications.

•	CCITT Recommendation V.ll (orX.27), Electrical
characteristics for balanced double-current interchange
circuits for general use with integrated circuit equipment
in the field of data communications.

*	ISO 4902-1980 (E), Data communication - 37-pin and 9-pin
DTE/DCE Interface connectors and pin assignments.

Estos manuales están disponibles para el equipo anterior:

Tipo de manual: Manual del usuario TTC-8346-Manual-Page-1-Picture
Páginas: 31
Tamaño: 872.33 Kbytes (893264 Bytes)
Idioma Inglés
Revisión:
Manual-/ número de identificación: 50-11032-01
Fecha: 01 septiembre 1989
Calidad: Documento electrónico, sin análisis, muy bien legible.
Fecha de carga:
MD5: 7654a7a19a965ed4e12ee713cffb8dee
Descargas: 84 desde 08 enero 2017
Información:
1	GENERAL
INFORMATION ... 1-1

1.1	Introduction
 ... 1-1

1.2	Interface
Features ... 1-1

1.3	Interface Compatibility
 ... 
1-1.

1.4	Options And
Accessories ... 1-2

2	INTERFACE DESCRIPTION
 ... 2-1

2.1
Introduction ... 2-1

2.2	Physical Description
 ... 2-1

2.2.1	Interface Switches
 ... 2-1

2.2.2	Interface Connector
 ... 2-3

2.3 Functional
Description ... 2-4

2.3.1	Operating as the
DTE ... 2-6

2.3.2	Operating as the
DCE ... 2-6

2.3.3	Self-Loop Testing
 ... 2-6

3	INSTALLING AND SETTING UP THE Interface
 ... 3-1

3.1
Introduction ... 3-1

3.2	Installing The Interface
 ... 3-1

3.3	Interface
Setup ... 3-1

4	SETTING UP THE FIREBERD 6000
 ... 4-1

4.1
Introduction ... 4-1

4.2	Fireberd 6000 Mainframe
Set-up ... 4-1

4.3	Mainframe Auxiliary Functions
 ... 4-2

4.4	Mainframe Printer
Operation ... 4-2

5	SETTING UP THE Fireberd 4000
 ... 5-1

5.1
Introduction ... 5-1

5.2	Fireberd 4000 Mainframe
Set-up ... 5-1

5.3	Mainframe Printer
Operation ... 5-1.

6	INTERFACE SPECIFICATIONS
 ... 6-1

6.1
Introduction ... 6-1

7	MAINTENANCE AND SERVICE
 ... 7-1

7.1
Introduction ... 7-1

7.2
Maintenance ... 7-1

7.2.1	In Case of Difficulty
 ... 7-1

7.3
Service ... 7-1

7.3.1	Warranty
Policy ... 7-1

7.3.2	In-Warranty
Service ... 7-2

7.3.3	Out-of-Warranty
Service ... 7-2

7.3.4	Equipment Return Instructions
 ... 7-2
TTC-8346-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics