Fluke 685 Analyzer
Fabricante:
Imagen 1 de 3
Imagen 2 de 3
Imagen 3 de 3
Si tienes otras fotos o manuales para el
Fluke 685 puedes subir los archivos aquí .
Modelo:
685
Fecha:
1999
Categoría:
Grupo:
Descripción:
Enterprise LANMeter
Información
The Fluke Enterprise LANMeter (68x Series) instruments are
versatile battery- operated handheld instruments used to
isolate many problems that can occur on your Ethernet and
Token Ring networks. The Fluke Enterprise LANMeter series
consists of the Fluke 686, Fluke 685, Fluke 683, Fluke 682,
and Fluke 680 LANMeter instruments.
The Fluke 686 and 683 instruments provide the capability of
connecting to Fast (100 Mbps) Ethernet networks. The
capabilities of the Fluke 686 and 683 instruments are also
documented throughout this Users Manual
The 100 MHz Cable Test option (also called 100 MHz Remote)
gives you additional cable test capabilities. The optional
100 MHz Remote is compatible with all Fluke 68x Series
instruments except some Fluke 67x Series instruments
upgraded to 68x Series. Your 67x instrument is compatible
with the 100 MHz Remote if its serial number is as described
in Table 1-2 or if your instrument displays 100 MHz Cable
Test Compatible in the power- on screen or in the top-level
softkey screen. The 100 MHz Cable Test option is covered in
Chapter 4 “Testing Cables and Connectors.”
The SwitchWizard option enhances Segment Discovery and adds
the SwitchWizard MultiPort Statistics test. SwitchWizard
gives you the ability to discover and diagnose problems on
the other side of Ethernet, Token Ring, and FDDI switches.
SwitchWizard is compatible with all Fluke 68x Series
instruments with Software version 7.0 or greater, and is
covered in Chapter 9 “SwitchWizard Option.”
The WideAreaWizard option enhances the Internet Toolkit’s
Interface Table by adding reporting and some configuration
capabilities for discovered WAN interfaces. WideAreaWizard
gives you the ability to discover and diagnose problems on
Frame Relay, ISDN, and Tl/El interfaces on routers,
switches, and bridges. WideAreaWizard also allows you to
display and configure virtual circuit information for
appropriate technologies. WideAreaWizard is compatible with
all Fluke 68x Series instruments with Software version 8.0
or greater, and is covered in Chapter 12 "‘WideAreaWizard
Option.”
The WebRemote Control option adds the ability to control
your LANMeter instrument remotely using a web browser.
WebRemote Control is compatible with all Fluke 68x Series
instruments with Software version 9.0 or greater, and is
covered in Chapter 13 “Web Agent / WebRemote Control.”
This manual generally refers to features common to all the
Fluke 68x Series LANMeter instruments as the “Enterprise
LANMeter” or as the “LANMeter instrument.” The individual
Fluke 68x Series model number is used when features are
specific to an individual model of the Enterprise LANMeter.
Type manuel:
Manual del usuario
Páginas:
455
Tamaño:
17.21 Mbytes (18047016 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
804028
Fecha:
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2016 01 28
MD5:
0ad1b9aaf88d51122c5d768f50011638
Descargas:
3772
Información
1 Introduction: Introduces the Fluke Enterprise LANMeter™
(68x Series) instruments and lists the supplied equipment.
2 Quick Start: Provides information about the initial setup
of the Enterprise LANMeter, attaching cables, running cable
and network tests, and selecting a test.
3 Getting Acquainted with Your Instrument: Provides
information about the user Interface, configuration, and
using the Help System.
4 Testing Cables and Connectors: Provides information about
running cable tests and interpreting test results.
5 Monitoring the Network: Provides information about running
network monitor tests and interpreting test results.
6 Testing Network Components: Provides information about
running network component tests and interpreting test results.
7 Testing Novell NetWare: Provides information about running
Novell NetWare tests and interpreting test results.
8 Testing TCP/IP Networks: Provides information about
running TCP/IP Network tests, TCP/IP Internetwork tests, and
interpreting test results.
9 SwitchWizard Option: Provides information about running
the SwitchWizard™ Option and interpreting test results.
10 Testing Banyan VINES: Provides information about running
Banyan VINES tests and interpreting test results.
11 Testing NetBIOS: Provides information about running
NetBIOS tests and interpreting test results.
12 WideAreaWizard Option: Provides information about running
the WideAreaWizard™ Option and interpreting test results.
13 Web Agent / WebRemote Control: Provides information about
using and configuring the LANMeter instrument as a web
server so that its results can be accessed using a web browser.
14 File Manager: Provides information about using File
Manager for configuring the instrument, selecting previously
saved files, and performing actions on the Reports &
Graphics, Data Log, and Station List files.
Type manuel:
Manual del usuario
Páginas:
470
Tamaño:
17.53 Mbytes (18382583 Bytes)
Idioma:
english
Revisión:
Manuel-ID:
PN 804028
Fecha:
Formato:
Documento Scaned, todo legible.
Fecha de subida:
2016 06 12
MD5:
2400ae72cdae3e7237f3d2784fb5233e
Descargas:
3992
Información
1
Introduction ... 1-1
Chapter
Summary ... 1-1
Fluke 68x Series
Instruments ... 1-3
Equipment
Supplied ... 1-5
2 Quick
Start ... 2-1
Online
Help ... 2-1
Interface Mode
Icons ... 2-2
Setting Up Your
Instrument ... 2-2
Connecting the AC
Adapter ... 2-3
Setting Time and
Date ... 2-3
Changing the
Interface ... 2-4
Attaching
Cables ... 2-4
Running a
Test ... 2-10
Running Cable
Tests ... 2-11
Running Network
Statistics ... 2-12
Ethernet Network
Statistics ... 2-12
Token Ring Network
Statistics ... 2-16
Overview of
Tests ... 2-21
3 Getting Acquainted with Your
Instrument ... 3-1
User
interface ... 3-1
LCD
Display ... 3-3
Keyboard ... 3-5
LED
Indicators ... 3-15
Configuring Your
Instrument ... 3-20
Network
Configuration ... 3-22
Station
List ... 3-24
User-Defined
Stations ... 3-26
Predefined
Stations ... 3-26
Station List Pop-up
Menu ... 3-27
Importing Novell and IP Host
Tables ... 3-30
Manage
Options ... 3-30
Time and
Date ... 3-30
Display
Configuration ... 3-31
Additional Features and
Functionality ... 3-31
File
Manager ... 3-32
Web
Agent ... 3-32
System
Information ... 3-32
Update
Software ... 3-32
View
All ... 3-33
Self-Tests ... 3-34
Accessing the Help
System ... 3-36
4 Testing Cables and
Connectors ... 4-1
The Fiber Test
Option ... 4-2
Ensuring Accurate
Measurements ... 4-3
Setting a
Reference ... 4-3
Measuring Optical
Loss ... 4-5
Measuring Output
Power ... 4-6
Fiber Test
Results ... 4-7
The 100 MHz
Remote ... 4-8
Attaching Cables for the 100 MHz
Remote ... 4-10
Calibrate the 100 MHz
Remote ... 4-10
100 MHz Remote
Accessories ... 4-11
Attaching
Cables ... 4-11
Configuring Cable
Tests ... 4-11
Running Cable
Tests ... 4-16
Description of Cable
Tests ... 4-17
Cable
Scan ... 4-17
Wire
Map ... 4-21
Cable
Identifier ... 4-24
Cable
Autotest ... 4-25
100 Ohm Twisted Pair Cable
Autotest ... 4-27
Coax and 150 Ohm STP Cable
Autotest ... 4-34
NEXT ... 4-35
Attenuation ... 4-38
DC Continuity (Fluke 686, 685, 683, and 682
Only) ... 4-42
Find
NVP ... 4-42
Calibrate
Remote ... 4-43
5 Monitoring the
Network ... 5-1
Configuring Network Monitor
Tests ... 5-2
Running Network Monitor
Tests ... 5-3
Ethernet
Tests ... 5-4
Network
Statistics ... 5-5
Error
Statistics ... 5-8
Ethernet Network Health Overview and
Guidelines ... 5-15
Token Ring
Tests ... 5-16
Network
Statistics ... 5-17
Error
Statistics ... 5-19
Ring
Stations ... 5-26
Merging New Stations into Station
List ... 5-28
Viewing the Active Monitor
History ... 5-28
Beacon Alert Pop-Up
Window ... 5-29
Token Rotation
Time ... 5-30
Token Ring Network Health Overview and
Guidelines ... 5-31
Data
Logging ... 5-33
MAC
Matrix ... 5-37
Protocol
Mix ... 5-38
Cisco ISL VLAN Protocol
Mix ... 5-39
Top
MAC ... 5-40
Top Senders and Top
Receivers ... 5-41
Top
Broadcasters ... 5-43
6 Testing Network
Components, ... , ... 6-1
Configuring Network Component
Tests ... 6-2
Running Network Component
Tests ... 6-3
NIC/MAU and NIC/Hub
Tests ... 6-4
Ethernet NIC/Hub
Tests ... 6-5
Token Ring NIC/MAU
Tests ... 6-11
Network
Tests ... 6-18
Station
Ping ... 6-18
Phase
Jitter ... 6-20
Adapter
Status ... 6-22
Remove
Station ... 6-24
Traffic
Generator ... 6-25
7 Testing Novell
NetWare ... 7-1
Configuring Novell NetWare
Tests ... 7-2
Running Novell NetWare
Tests ... 7-3
Description of the Novell NetWare
Tests ... 7-3
Server
List ... 7-4
NetWare
Ping ... 7-6
NetWare Stats (File and Packet
Statistics) ... 7-7
Routing
Analysis ... 7-9
Top NetWare (Top Senders and Top
Receivers) ... 7-10
8 Testing TCP/IP
Networks ... 8-1
Attaching
Cables ... 8-2
Configuring Enterprise LANMeter’s IP
Parameters ... 8-2
Manually Configuring Enterprise
LANMeter ... 8-3
Configuring Internet TCP/IP Test
Targets ... 8-4
Running Internet TCP/IP
Tests ... 8-5
Using Hyperlink
Tests ... 8-6
Hyperlink
Tests ... 8-6
Description of Internet TCP/IP
Tests ... 8-10
IP Auto
Config ... 8-10
Segment
Discovery ... 8-14
Configuring Key
Devices ... 8-15
Results ... 8-17
Problem
Solving ... 8-20
Merging
Stations ... 8-21
Scan
Host ... 8-21
Trace
Route ... 8-22
Internet
Toolkit ... 8-27
ICMP
Monitor ... 8-40
ICMP
Ping ... 8-43
Top IP (Top Senders and Top
Receivers) ... 8-45
IP
Matrix ... 8-47
9 SwitchWizard
Option ... 9-1
Enabling the SwitchWizard
Option ... 9-2
SwitchWizard for Segment
Discovery ... 9-4
SwitchWizard’s MultiPort Statistics
Test ... 9-6
Configuring the MultiPort Statistics
Test ... 9-6
MultiPort Statistics Test
Features ... 9-6
Sort
Options ... 9-10
Find
Port ... 9-11
Stats
Detail ... 9-12
SwitchWizard for the Internet
Toolkit ... 9-19
10 Testing Banyan
VINES ... 10-1
Configuring Banyan VINES
Tests ... 10-2
Running Banyan VINES
Tests ... 10-3
Description of the Banyan VINES
Tests ... 10-3
Address
Server ... 10-4
Server
Discovery ... 10-5
Top VINES (Top Senders and Top
Receivers) ... 10-6
11 Testing NetBIOS (Microsoft and IBM PC
Networks) ... 11-1
Running NetBIOS
Tests ... 11-3
Description of the NetBIOS
Tests ... 11-3
NetBIOS
Discovery ... 11-4
NetBIOS
Ping ... 11-6
Top NetBIOS (Top Senders and Top
Receivers) ... 11-9
12 WideAreaWizard
Option ... 12-1
Enabling the WideAreaWizard
Option ... 12-2
WideAreaWizard for the Internet
Toolkit ... 12-4
Interface T
able ... 12-4
Interface Statistics and
Errors ... 12-5
Virtual Circuits
... 12-9
Circuit
Detail ... 12-11
Source
Details ... 12-11
Frame
Relay ... 12-12
ISDN ... 12-13
Tl/El ... 12-14
13 Web Agent / WebRemote
Control ... 13-1
Your Instrument as a Web
Server ... 13-2
Configuration
Parameters ... 13-2
Configuring and Running Web
Agent ... 13-3
Viewing Instrument Information with a Web
Browser ... 13-4
Home ... 13-6
L ANMeter
Display/Remote ... 13-6
File
Manager ... 13-7
Reports and
Graphics ... 13-7
Data
Logs ... 13-8
Station
Lists ... 13-10
LANMeter
News ... 13-11
Web Agent Frequently Asked
Questions ... 13-11
Useful Networking
Links ... 13-11
WebRemote Control
Option ... 13-12
Enabling WebRemote
Control ... 13-12
Configuring WebRemote
Control ... 13-13
Running WebRemote
Control ... 13-14
14 File
Manager ... 14-1
File
Types ... 14-3
Preview
Files ... 14-5
Preview ASCII Report
Files ... 14-5
Configure File
Manager ... 14-7
Email Configuration
Parameters ... 14-8
TCP/IP Configuration
Parameters ... 14-9
Printer/Port Configuration P
arameters ... 14-9
Mark
Files ... 14-10
File Manager
Actions ... 14-10
Email Error
Handling ... 14-12
Attaching Printer
Cables ... 14-12
Appendices
A Troubleshooting
Scenarios ... A-l
B
Specifications ... B-l
C
Maintenance ... C-l
D
Utilities ... D-l
E
Glossary ... E-l
Index