Keithley - 662 - Amplificador
Fabricante:
No hay imágenes disponibles!
Tal vez puedas
subir una foto
para el
Keithley 662 ?
Si dispone de otros manuales para el
Keithley 662
puede
subir los archivos aquí.
.
Equipamiento:
662
Fecha:
1965
Categoría:
Grupo:
Subgrupo:
Información
The Keithley Model 662 Guarded dc Differential Voltmeter is an extremely precise self-contained, guarded potentiometer. It measures from 100 millivolts to 500 volts with 0,01% limit of error, and below 100 millivolts within 10 microvolts. Since the limit of error includes all stability considerations, the unit need not be periodically calibrated or manually restandardized for a full year. The 500-volt reference supply permits infinite impedance at null for measurements from 0 to 500 volts. Six dials assure that every voltage setting has at least 5-dial resolution.
b. Features for convenient use include: six in-line readout dials with automatically lighted decimal points; 10 to 25-millivolt recorder output; input polarity switch; floating operation up to 500 volts off chassis ground; line frequency rejection greater than 45 db. Also, full guarding minimizes leakage problems.
OPERATING MODES. The Model 662 can be used as a potentiometer or as a conventional vacuum tube voltmeter. As a potentiometer, it measures from 100 millivolts full scale to 500 volts with +/-0.01% limit of error and from 100 microvolts full scale to 100 millivolts within 10 microvolts. As a VTVM, the Model 662 measures from 1 millivolt full scale to 500 volts with an accuracy of +/- 3% of full scale. It can also measure resistances from 1 megohm to 100,000 megohms within +/- 5%.
1 Manual
Manual de servicio y del usuario
Tipo manual:
Manual de servicio y del usuario
Páginas:
49
Tamaño:
3,5 MB
Idioma:
ingles
Revisión:
Manual-ID:
Fecha:
enero 1965
Calidad:
Documento escaneado, en parte se lee mal, en parte no se lee.
Fecha de carga:
24 de julio de 2020
MD5:
5cba3597-bd65-89e1-978a-4cded0b354a2
Información
1. GENERAL DESCRIPTION .......
1-1. Description ....... . 1
1-2. . 1
1-3. Applications ....... . 1
1-4. Specifications ...... . 2
1-5. Accessories ........ . 3
1-6. Equipment Shipped .....
2. OPERATION . •........... . 5
2-1. Front Panel Controls
. 5
2-2. Rear Controls and
Terminals ........ . 5
2-3. Preliminary Procedures. . . . 6
2-4. Operating Procedures. . . . . 6
2-5. Recorder Output ...... . 8
2-6. Effects Due to Kelvin-
Varley Divider Out-
put Resistance ...... . 9
2-7. Effective Input Resis-
tcinc^ « ••••»■«** . 9
2-8. Thermal EMF Precau-
. 10
2-9. AC Effects on Measurement . . 10
3. APPLICATIONS .......... . 11
3-1. Procedures for Measuring
Resistances ....... . 11
3-2. Theory of Measuring Resis-
. U
4. CIRCUIT DESCRIPTION ....... 13
4-1. . 13
4-2. Reference Voltage Supply. . . 13
4-3. Kelvin-Varley Divider . . . . 14
4-4. Null Detector ....... . 14
4-5. . 15
5. SERVICING ............ 17
5-1. . 17
5-2. Servicing Schedule..... . 17
5-3. . 17
5~4. Troubleshooting ...... . 17
5-5. Adjusting Hum Bal Control . . 19
5-6. Zener Diode Replacement , . . 19
5-7. Meter Adjustment ..... . 19
6. CALIBRATION ........... . 21
6-1. General .......... . 21
6-2. Calibration Schedule. . . . . 22
6-3. Kelvin-Varley Divider . . .
Verification .......
6-4. Range Calibration . ... . , . 23'
6-5. Reference Voltage Supply
Stability Test ...... . 25
6-6. Oscillator Adjustment . . . . 27
7. ACCESSORIES ........... . 35
7-1. Model 6601A High Voltage
Divider ......... . 35
7-2. Rack Mounting .......
7-3. Placing in Rack ...... . 36
8. REPLACEABLE PARTS ........ . 37
8-1. Replaceable Parts List. . . . 37
8-2. How to Order Parts..... . 37
Model 662 Replaceable
Parts List ........ . 38
Model 6601A Replaceable
Farts List ........
Model 662 Schematic Diagram
1855 IE.......... . 47
Model 6601A Schematic Diagram
16321B .......... , 49
Change Last Page