Información

The Keithley Model 662 Guarded dc Differential Voltmeter is an extremely precise self-contained, guarded potentiometer. It measures from 100 millivolts to 500 volts with 0,01% limit of error, and below 100 millivolts within 10 microvolts. Since the limit of error includes all stability considerations, the unit need not be periodically calibrated or manually restandardized for a full year. The 500-volt reference supply permits infinite impedance at null for measurements from 0 to 500 volts. Six dials assure that every voltage setting has at least 5-dial resolution. b. Features for convenient use include: six in-line readout dials with automatically lighted decimal points; 10 to 25-millivolt recorder output; input polarity switch; floating operation up to 500 volts off chassis ground; line frequency rejection greater than 45 db. Also, full guarding minimizes leakage problems. OPERATING MODES. The Model 662 can be used as a potentiometer or as a conventional vacuum tube voltmeter. As a potentiometer, it measures from 100 millivolts full scale to 500 volts with +/-0.01% limit of error and from 100 microvolts full scale to 100 millivolts within 10 microvolts. As a VTVM, the Model 662 measures from 1 millivolt full scale to 500 volts with an accuracy of +/- 3% of full scale. It can also measure resistances from 1 megohm to 100,000 megohms within +/- 5%.

ver más

1 Manual

Manual de servicio y del usuario
Tipo manual:
Manual de servicio y del usuario
Páginas:
49
Tamaño:
3,5 MB
Idioma:
ingles
Revisión:
Manual-ID:
Fecha:
enero 1965
Calidad:
Documento escaneado, en parte se lee mal, en parte no se lee.
Fecha de carga:
24 de julio de 2020
MD5:
5cba3597-bd65-89e1-978a-4cded0b354a2

Información

1. GENERAL DESCRIPTION ....... 1-1. Description ....... . 1 1-2. . 1 1-3. Applications ....... . 1 1-4. Specifications ...... . 2 1-5. Accessories ........ . 3 1-6. Equipment Shipped ..... 2. OPERATION . •........... . 5 2-1. Front Panel Controls . 5 2-2. Rear Controls and Terminals ........ . 5 2-3. Preliminary Procedures. . . . 6 2-4. Operating Procedures. . . . . 6 2-5. Recorder Output ...... . 8 2-6. Effects Due to Kelvin- Varley Divider Out- put Resistance ...... . 9 2-7. Effective Input Resis- tcinc^ « ••••»■«** . 9 2-8. Thermal EMF Precau- . 10 2-9. AC Effects on Measurement . . 10 3. APPLICATIONS .......... . 11 3-1. Procedures for Measuring Resistances ....... . 11 3-2. Theory of Measuring Resis- . U 4. CIRCUIT DESCRIPTION ....... 13 4-1. . 13 4-2. Reference Voltage Supply. . . 13 4-3. Kelvin-Varley Divider . . . . 14 4-4. Null Detector ....... . 14 4-5. . 15 5. SERVICING ............ 17 5-1. . 17 5-2. Servicing Schedule..... . 17 5-3. . 17 5~4. Troubleshooting ...... . 17 5-5. Adjusting Hum Bal Control . . 19 5-6. Zener Diode Replacement , . . 19 5-7. Meter Adjustment ..... . 19 6. CALIBRATION ........... . 21 6-1. General .......... . 21 6-2. Calibration Schedule. . . . . 22 6-3. Kelvin-Varley Divider . . . Verification ....... 6-4. Range Calibration . ... . , . 23' 6-5. Reference Voltage Supply Stability Test ...... . 25 6-6. Oscillator Adjustment . . . . 27 7. ACCESSORIES ........... . 35 7-1. Model 6601A High Voltage Divider ......... . 35 7-2. Rack Mounting ....... 7-3. Placing in Rack ...... . 36 8. REPLACEABLE PARTS ........ . 37 8-1. Replaceable Parts List. . . . 37 8-2. How to Order Parts..... . 37 Model 662 Replaceable Parts List ........ . 38 Model 6601A Replaceable Farts List ........ Model 662 Schematic Diagram 1855 IE.......... . 47 Model 6601A Schematic Diagram 16321B .......... , 49 Change Last Page

ver más

Descargas: