Fluke - 8050A - Multímetro digital
Fabricante:
Equipamiento:
8050A
Fecha:
1979
Categoría:
Grupo:
Subgrupo:
Información
1-2. Your John Fluke Model 8050A is a portable bench-
type Digital multimeter (DMM) with a 4-1 /2 digit liquid
crystal display (LCD). The 8050A has all the following
industry-standard features:
» Voltage measurements from 10 μ to 1000V dcand 10 mV to
750V true-rms ac.
• Current measurements from 10 nA to 2A dc and 10 μΑ to 2A
true-rms ac.
® Resistance measurements from 10 mH to 20ΜΏ.
The 8050A also has several special measurement features.
These special features include the following:
• Conductance measurements up to 100,000 Mil.
• Voltage measurements in decibels, that can be referenced
to 1 of 16 user selected reference impedances.
® Resistance ranges that supply enough voltage to turn on a
PN junction to allow diodes and transistors to be tested.
• The ability to store any input signal as an offset or
relative reference value.
• Automatic polarity indication and overrange indication.
• Protection from overloads and protection from transients
of up to 6 kV, 10 microseconds.
• Dual-slope integration a/d conversion to ensure noise-free
measurements.
• Long term calibration stability (1 year).
1-3. The 8050A is warranted for a period of one year upon
shipment of the instrument to the original purchaser.
Conditions of the warranty are given at the front of this
manual. The 8050A is typically powered from ac line voltages
but may be powered by the optional rechargeable battery.
3 Manuales
Manual del usuario con esquemas
Tipo manual:
Manual del usuario con esquemas
Páginas:
97
Tamaño:
2,9 MB
Idioma:
ingles
Revisión:
2 7/84
Manual-ID:
530907
Fecha:
Calidad:
Documento escaneado, todo legible.
Fecha de carga:
19 de febrero de 2009
MD5:
8c0a3ade-3a51-72d5-2d90-ef6687562db8
Descargas:
3692
Descargas del mes pasado:
3
Descargar
fluke--8050a--user-schematics--ID1437.pdf
Manual de servicio y del usuario
Tipo manual:
Manual de servicio y del usuario
Páginas:
104
Tamaño:
8,5 MB
Idioma:
ingles
Revisión:
2
Manual-ID:
530907
Fecha:
Calidad:
Documento escaneado, todo legible.
Fecha de carga:
27 de enero de 2016
MD5:
9046d898-8f51-2b66-5539-42430b1b1d33
Información
1 INTRODUCTION AND SPECIFICATIONS 1-1
1-1. INTRODUCTION 1-1
1-4. OPTIONS AND Accessories 1-1
1-5. SPECIFICATIONS
...
1-1
2 OPERATION
...
2-1
2-1. INTRODUCTION
...
2-1
2-3. SETTING UP YOUR INSTRUMENT ... 2-1
2-4. Unpacking
...
2-1
2-8. AC Line Voltage Requirements 2-1
2-10. Fuse Replacement 2-1
2-13. FRONT PANEL FEATURES 2-2
2-15. Display 2-2
2-18. SIGNAL INPUT LIMITS 2-2
2-20. OPERATING TECHNIQUES 2-3
2-22. AC/DC Voltage (V) 2-3
2-24. AC/ DC Current (mA) 2-3
2-26. Resistance (Ω) 2-7
2-28. Conductance (S = 1Ω) 2-7
2-30. Diode Test 2-7
2-32. Relative (RELATIVE) 2-7
2-36. Decibel (dB) 2-11
2-38. INITIAL CHECKOUT PROCEDURE ... 2-12
2-41. APPLICATIONS 2-12
2-43. DC Voltage Measurement 2-12
2-51. Current Measurement 2-13
2-56. Resistance Measurement 2-13
2-62. Conductance Measurement 2-14
2-80. Relative Measurement 2-16
2-84. AC Voltage and Current
Measurement... 2-16
3 THEORY OF
OPERATION...
3-1
3-1. INTRODUCTION
...
3-1
3-3. FUNCTIONAL DESCRIPTION 3-1
TITLE PAGE
3-7. A/D Converter 3-1
3-18. Microcomputer
...3-2
3-20. Signal Conditioning
...3-6
3-31. True-RMS Converter 3-8
3-38. Touch-Hold Circuit
...3-8
3-40. Voltage Protection
...3-8
3-43. Current Protection
...3-8
4 MAINTENANCE
...
4-1
4-1. INTRODUCTION
...
4-1
4-4. SERVICE INFORMATION
...
4-1
4-7. GENERAL INFORMATION
...
4-1
4-9. Interior
Access...
4-1
4-24. dB Reference Impedance Power-Up
Setting... 4-4
4-26. Cleaning
...
4-5
4-28. PERFORMANCE TESTS
...
4-5
4-30. Initial Procedures
...
4-5
4-32. Display
Test...
4-5
4-34. Linear Voltage Test
...
4-6
4-36. dB Voltage
Test...
4-6
4-38. Current
Test...
4-7
4-40. Resistance and Conductance
Tests... 4-7
4-42. CALIBRATION ADJUSTMENTS
... 4-8
4-44. DC Calibration
...
4-8
4-46. AC Calibration
...
4-8
4-48. Jumper
Selection...
4-8
4-57. TROUBLESHOOTING
...
4-12
5 LIST OF REPLACEABLE PARTS
...
5-1
TABLE OF CONTENTS
...
5-1
5-1. INTRODUCTION
...
5-2
5-3. PARTS ORDERING INFORMATION
... 5-2
6 OPTIONS AND Accessories 6-1
TABLE OF CONTENTS
...
6-1
INTRODUCTION
...
6-2 Accessories 600-1
OPTIONS
...
601-1
7 SCHEMATIC DIAGRAMS
...
7-1
TABLE OF CONTENTS
...
7-1
APPENDIX A
...
A-1
Descargas:
1130
Descargas del mes pasado:
10
Descargar
fluke--8050a--service-user--ID7619.pdf
Manual de servicio y del usuario
Tipo manual:
Manual de servicio y del usuario
Páginas:
106
Tamaño:
5,1 MB
Idioma:
ingles
Revisión:
2
Manual-ID:
530907
Fecha:
Calidad:
Documento escaneado, todo legible.
Fecha de carga:
13 de febrero de 2016
MD5:
645b1f5f-0f6c-33dd-dc5f-e37e20c5466f
Información
1
2
TITLE PAGE
INTRODUCTION AND SPECIFICATIONS
... 1-1
l-l. INTRODUCTION .
I-4. OPTIONS AND ACCESi
I-5. SPECIFICATIONS
...
1-1
SORIES...
1-1
...
1-1
OPERATION
...
2-1
2-1. INTRODUCTION
...
2-1
2-3. SETTING UP YOUR INSTRUMENT
... 2-1
2-4. Unpacking
...
2-1
2-8. AC Line Voltage Requirements
...
2-1
2-10. Fuse
Replacement...
2-1
2-13. FRONT PANEL
FEATURES...
2-2
2-15. Display
...
2-2
2-18. SIGNAL INPUT LIMITS
...
2-2
2-20. OPERATING
TECHNIQUES...
2-3
2-22. AC/DC Voltage (V)
...
2-3
2-24. AC/DC Current (mA)
...
2-3
2-26. Resistance (Ω)
...
2-7
2-28. Conductance (S =
IΩ)...
2-7
2-30. Diode Test
...
2-7
2-32. Relative (RELATIVE)
...
2-7
2-36. Decibel
(dB)...
2-11
2-38. INITIAL CHECKOUT PROCEDURE
... 2-12
2-41. APPLICATIONS
...
2-12
2-43. DC Voltage Measurement
...,...
2-12
2-51. Current Measurement
...
2-13
2-56. Resistance Measurement
...
2-13
2-62. Conductance Measurement
...
2-14
2-80. Relative Measurement
...
2-16
2-84. AC Voltage and Current
Measurement... 2-16
THEORY OF
OPERATION...
3-1
3-1. INTRODUCTION
...
3-1
3-3. FUNCTIONAL DESCRIPTION
... 3-1
3-5. CIRCUIT
DESCRIPTION...
3-1
TITLE PAGE
3-7. A/D Converter 3-1
3-18. Microcomputer
...3-2
3-20. Signal Conditioning
...3-6
3-31. True-RMS Converter 3-8
3-38. Touch-Hold Circuit
...3-8
3-40, Voltage Protection
...3-8
3-43. Current Protection
...3-8
4 MAINTENANCE
...
4-1
4-1. INTRODUCTION
...
4-1
4-4. SERVICE INFORMATION
...
4-1
4-7. GENERAL INFORMATION
...
4-1
4-9. Interior
Access...
4-1
4-24. dB Reference Impedance Power-Up
Setting... 4-4
4-26. Cleaning
...
4-5
4-28. PERFORMANCE TESTS
...
4-5
4-30. Initial Procedures
...
4-5
4-32. Display
Test...
4-5
4-34. Linear Voltage Test
...*...
4-6
4-36. dB Voltage
Test...
4-6
4-38. Current
Test...
4-7
4-40. Resistance and Conductance Tests
... 4-7
4-42. CALIBRATION ADJUSTMENTS
... 4-8
4-44. DC Calibration ...
... 4-8
4-46. AC Calibration ...
... 4-8
4-48. Jumper
Selection...
4-8
4-57. TROUBLESHOOTING
...
4-12
5 LIST OF REPLACEABLE PARTS
...
5-1
TABLE OF CONTENTS
...
5-1
5-1. INTRODUCTION
...
5-2
5-3. PARTS ORDERING INFORMATION
... 5-2
6 OPTIONS AND Accessories 6-1
TABLE OF CONTENTS
...
6-1
INTRODUCTION
...
6-2 Accessories 600-1
OPTIONS
...
601-1
7 SCHEMATIC DIAGRAMS
...
7-1
TABLE OF CONTENTS
...
7-1
APPENDIX A
...
A-1
Descargas:
2177
Descargas del mes pasado:
13
Descargar
fluke--8050a--service-user--ID7727.pdf