Fluke - 5700A Series II - Calibrador
Fabricante:
No hay imágenes disponibles!
Tal vez puedas
subir una foto
para el
Fluke 5700A Series II ?
Si dispone de otros manuales para el
Fluke 5700A Series II
puede
subir los archivos aquí.
.
Equipamiento:
5700A Series II
Fecha:
1996
Categoría:
Grupo:
Subgrupo:
Información
The Fluke Model 5700A/5720A Series II calibrators are
precise instruments that
calibrate a wide variety of electrical measuring
instruments. These calibrators maintain
high accuracy over a wide ambient temperature range,
allowing them to test instruments
in any environment, eliminating the restrictions to
calibrate only in a temperaturecontrolled
standards laboratory. With a 5700A/5720A Series II, you can
calibrate
precision multimeters that measure ac or dc voltage, ac or
dc current, and resistance. The
5720A Series II operates in a similar manner to the 5700A
Series II, the difference is that
the 5720A Series II has a considerably higher specified
accuracy. Option 5700A-03
Wideband AC Voltage, which is available for both the 5700A
Series II and the 5720A
Series II, extends this workload to include rf voltmeters.
Specifications are provided at the end of this chapter. The
calibrator is a fully programmable
precision source of the following:
· DC voltage to 1100V
· AC voltage to 1100V, with output available from 10 Hz to
1.2 MHz.
· AC and DC current to 2.2A, with output available from 10
Hz to 10 kHz
· Resistance in values of 1x10n and 1.9x10n from 1W to 100
MW, plus a short.
· Optional wideband ac voltage from 300 μV to 3.5V into 50W
(-57 dBm to
+24 dBm), 10 Hz to 30 MHz.
Features of the calibrator include the following:
· Internal environmentally-controlled references allowing
the calibrator to maintain
full performance over a wide ambient temperature range.
· Automatic meter error calculation obtained through using a
simple output adjust
knob; the display shows linearity, offset, and scale errors.
· Keys that multiply and divide the output value by 10 to
simplify work on meters
with calibration points at decade multiples of a fraction of
full-scale.
· Programmable entry limits used for restricting the levels
that can be keyed into the
calibrator, preventing access to levels that may be harmful
to equipment or
personnel.
· A s key that provides the capability of displaying the
instrument’s specification at
the selected operating point, calibration interval, and
specification confidence level.
· An auxiliary current binding post that allows you to
calibrate meters with separate
current inputs without moving cables.
· Real-time clock and calendar for date stamping reports.
· Offset and scaling modes that simplify linearity testing
of multimeters.
· Variable phase reference signal output and phase-lock input.
· Interface for the Fluke 5725 Amplifier.
· Standard IEEE-488 (GPIB) interface, complying with
ANSI/IEEE Standards 488.1-
1987 and 488.2-1987.
· Selectable normal remote mode or emulation of the Fluke
5100B and 5200A Series
calibrators in functions and response to system controller
software
· EIA Standard RS-232C serial data interface for printing,
displaying, or transferring
internally-stored calibration constants, and for remote
control of the calibrator.
3 Manuales
Manual de servicio
Tipo manual:
Manual de servicio
Páginas:
570
Tamaño:
38,0 MB
Idioma:
ingles
Revisión:
1
Manual-ID:
PN 601630
Fecha:
Calidad:
Documento electrónico, sin escaneo, muy bien legible.
Fecha de carga:
30 de noviembre de 2014
MD5:
54fe8d2e-d587-005d-4935-802b448ca82e
Descargas:
2274
Manual del usuario
Tipo manual:
Manual del usuario
Páginas:
40
Tamaño:
237,9 KB
Idioma:
ingles
Revisión:
Manual-ID:
601648
Fecha:
Calidad:
Documento escaneado, todo legible.
Fecha de carga:
6 de febrero de 2016
MD5:
939164dd-983a-5da4-5de3-1d61ac91d41d
Descargas:
1107
Manual del usuario
Tipo manual:
Manual del usuario
Páginas:
326
Tamaño:
2,2 MB
Idioma:
ingles
Revisión:
1
Manual-ID:
601622
Fecha:
Calidad:
Documento escaneado, todo legible.
Fecha de carga:
6 de febrero de 2016
MD5:
f0b336c8-d958-e93c-1f11-77b438195ea6
Descargas:
1197