Fluke - 5700A Series II - Calibrador
Fabricante:
Equipamiento:
5700A Series II
Fecha:
1996
Categoría:
Grupo:
Subgrupo:

Información

The Fluke Model 5700A/5720A Series II calibrators are precise instruments that calibrate a wide variety of electrical measuring instruments. These calibrators maintain high accuracy over a wide ambient temperature range, allowing them to test instruments in any environment, eliminating the restrictions to calibrate only in a temperaturecontrolled standards laboratory. With a 5700A/5720A Series II, you can calibrate precision multimeters that measure ac or dc voltage, ac or dc current, and resistance. The 5720A Series II operates in a similar manner to the 5700A Series II, the difference is that the 5720A Series II has a considerably higher specified accuracy. Option 5700A-03 Wideband AC Voltage, which is available for both the 5700A Series II and the 5720A Series II, extends this workload to include rf voltmeters. Specifications are provided at the end of this chapter. The calibrator is a fully programmable precision source of the following: · DC voltage to 1100V · AC voltage to 1100V, with output available from 10 Hz to 1.2 MHz. · AC and DC current to 2.2A, with output available from 10 Hz to 10 kHz · Resistance in values of 1x10n and 1.9x10n from 1W to 100 MW, plus a short. · Optional wideband ac voltage from 300 μV to 3.5V into 50W (-57 dBm to +24 dBm), 10 Hz to 30 MHz. Features of the calibrator include the following: · Internal environmentally-controlled references allowing the calibrator to maintain full performance over a wide ambient temperature range. · Automatic meter error calculation obtained through using a simple output adjust knob; the display shows linearity, offset, and scale errors. · Keys that multiply and divide the output value by 10 to simplify work on meters with calibration points at decade multiples of a fraction of full-scale. · Programmable entry limits used for restricting the levels that can be keyed into the calibrator, preventing access to levels that may be harmful to equipment or personnel. · A s key that provides the capability of displaying the instrument’s specification at the selected operating point, calibration interval, and specification confidence level. · An auxiliary current binding post that allows you to calibrate meters with separate current inputs without moving cables. · Real-time clock and calendar for date stamping reports. · Offset and scaling modes that simplify linearity testing of multimeters. · Variable phase reference signal output and phase-lock input. · Interface for the Fluke 5725 Amplifier. · Standard IEEE-488 (GPIB) interface, complying with ANSI/IEEE Standards 488.1- 1987 and 488.2-1987. · Selectable normal remote mode or emulation of the Fluke 5100B and 5200A Series calibrators in functions and response to system controller software · EIA Standard RS-232C serial data interface for printing, displaying, or transferring internally-stored calibration constants, and for remote control of the calibrator.

ver más

3 Manuales

Manual de servicio
Tipo manual:
Manual de servicio
Páginas:
570
Tamaño:
38,0 MB
Idioma:
ingles
Revisión:
1
Manual-ID:
PN 601630
Fecha:
Calidad:
Documento electrónico, sin escaneo, muy bien legible.
Fecha de carga:
30 de noviembre de 2014
MD5:
54fe8d2e-d587-005d-4935-802b448ca82e
Descargas:
2274
Manual del usuario
Tipo manual:
Manual del usuario
Páginas:
40
Tamaño:
237,9 KB
Idioma:
ingles
Revisión:
Manual-ID:
601648
Fecha:
Calidad:
Documento escaneado, todo legible.
Fecha de carga:
6 de febrero de 2016
MD5:
939164dd-983a-5da4-5de3-1d61ac91d41d
Descargas:
1107
Manual del usuario
Tipo manual:
Manual del usuario
Páginas:
326
Tamaño:
2,2 MB
Idioma:
ingles
Revisión:
1
Manual-ID:
601622
Fecha:
Calidad:
Documento escaneado, todo legible.
Fecha de carga:
6 de febrero de 2016
MD5:
f0b336c8-d958-e93c-1f11-77b438195ea6
Descargas:
1197