OUTPUT SPECIFICATIONS
Output Voltage Range: 0V to 35.3V (35V/10A); 0V to 18.15V
(18V/20A).
Output Current Range: 0.01A to 10.2A (35V/10A); 0.01A to
20.2A (18V/20A).
Output Voltage Setting: Direct keyboard entry or
quasi-analogue rotary control; setting
resolution 10mV.
Output Current Setting: Direct keyboard entry or
quasi-analogue rotary control; setting
resolution 10mA.
Output Mode: Constant voltage or constant current with
automatic crossover.
Output Switch: Electronic. Preset voltage and current
displayed when off.
Output Terminals: 4mm terminals on front panel, screw
terminals at rear.
Sensing: Remote via rear panel screw terminals or direct via
shorting strip
(supplied).
Output Impedance: <1mΩ in constant voltage mode.
>5kΩ in constant current mode (voltage limit at max.).
Output Protection: Forward protection by
Over-Voltage-Protection (OVP) trip;
maximum voltage that should be applied to the terminals is 50V.
Reverse protection by diode clamp for reverse currents up to 3A.
OVP Setting: Direct keyboard entry.
OVP Range: 1V to 40V (35V/10A); 1V to 25V (18V/20A).
OVP Delay: <200μs
Load & Line Regulation: <0.01% of maximum output for 90%
load change or 10% line
change.
Ripple & Noise: <1mV rms typical in constant voltage.
<3mA rms typical in constant current.
HF Common Mode Noise: Typically <3mV rms, <10mV peak.
Transient Response: 20μs to within 50mV of setting for 90%
load change.
Temperature Coefficient: typically <100 ppm/°C.
Protection Functions: Overvoltage trip; regulator
overtemperature; sense miswiring.
Status Indication: Output off lamp; constant voltage mode lamp;
constant current mode lamp; trip message on display.
METER SPECIFICATIONS
Meter Types: Dual 4 digit meters with 12·5mm (0.5") LEDs.
Reading rate 4Hz.
Meter Resolution: 10mV, 10mA
Meter Accuracy: Voltage 0.2% of reading ± 1 digit, current
0.5% of reading ± 1 digit.
KEYBOARD FUNCTIONS
Delta Mode: Increase or decrease voltage or current in
user-selectable steps.
Store/Recall: Store and recall voltage, current and OVP
levels from non-volatile
memory (25 memories).
Interface Selection: Set digital Interface type (RS232 or
GPIB), baud rate and address.
Manual type:
User Manual
Pages:
95
Size:
1.96 Mbytes (2052198 Bytes)
Language:
english, german, french
Revision:
Issue 12
Manual ID:
48511-0130
Date:
01 January 2009
Quality:
Electronic document, no scan, very well readable.
Upload date:
14 January 2017
MD5:
11956a66d324f0e3355b44f4cb497be5
Downloads:
467
Information
Specification 3
Safety 5
EMC 6
Installation 7
Manual Operation 8
Maintenance and Repair 11
Remote Operation 12
ARC Interface 13
Remote Commands 22
Instructions en Francais
Sécurité 34
Montage 35
Fonctionnement manuel 36
Entretien et Réparations 40
Fonctionnement à distance 41
Commandes à distance 52
Bedienungsanleitung auf Deutsch
Sicherheit 64
Installation 65
Handbedienung 66
Wartung und Instandsetzung 70
Fernbetrieb 71
Fernbefehle 82
1
Manual type:
User Manual
Pages:
95
Size:
867.72 Kbytes (888548 Bytes)
Language:
english, german, french
Revision:
Issue 13
Manual ID:
48511-0130
Date:
01 January 2013
Quality:
Electronic document, no scan, very well readable.
Upload date:
14 January 2017
MD5:
1b73ba08af63e918fc8289d61fdc62e3
Downloads:
248
Information
Specification 2
Safety 4
EMC 6
Installation 7
Manual Operation 8
Maintenance and Repair 11
Remote Operation 12
ARC Interface 13
Remote Commands 22
Instructions en Francais
Sécurité 34
Montage 35
Fonctionnement manuel 36
Entretien et Réparations 40
Fonctionnement à distance 41
Commandes à distance 52
Bedienungsanleitung auf Deutsch
Sicherheit 64
Installation 65
Handbedienung 66
Wartung und Instandsetzung 70
Fernbetrieb 71
Fernbefehle 82
Add Comment
Terms and Conditions
These terms and conditions contain rules about posting comments. By submitting a comment, you are declaring that you agree with these rules:
- Although the administrator will attempt to moderate comments, it is impossible for every comment to have been moderated at any given time.
- You acknowledge that all comments express the views and opinions of the original author and not those of the administrator.
- You agree not to post any material which is knowingly false, obscene, hateful, threatening, harassing or invasive of a person's privacy.
- The administrator has the right to edit, move or remove any comment for any reason and without notice.
Failure to comply with these rules may result in being banned from further commenting.
These terms and conditions are subject to change at any time and without notice.
Comments