Saime EOLE 3 XLS Ventilator
Manufacturer:
Model:
EOLE 3 XLS
Date:
Category:
Group:
Description:
Volumetric Pulmonary Ventilator
Service Manual
Manual type:
Service Manual
Pages:
59
Size:
20.18 Mbytes (21164304 Bytes)
Language:
english
Revision:
Manual ID:
NTA0004036-a
Date:
Quality:
Scanned document, all readable.
Upload date:
09 March 2018
MD5:
0f21de758788c530b213994168400a02
Downloads:
305
Information
1. SYNOPTICS _ 1-1 1.1 Eole 3 S ... 1-1 EOLE 3 XLS with oxygen option ... 1-3 2. ELECTRICAL POWER SUPPLY_ 2-5 2.1 Introduction ... 2-5 2.2 State of Charge of the Internal Battery (and XLS pack option) ... 2-6 2.3 Internal Batteries ... 2-6 2.4 Removable Battery Pack ... 2-7 2.5 Taking Out The Removable Battery Pack ... 2-7 2.6 SAIME heating base ... 2-7 3. PATIENT CIRCUIT _ 3-8 3.1 Patient circuit and volume control ... 3-8 3.2 Connecting the patient circuit and its accessories ... ! ... 3-8 3.2.1 Pneumatic Circuit Elements ... 3-8 3.2.2 Circuit Characteristics (plus accessories) ... 3-9 3.2.3 Setting up the complete pneumatic circuit ... 3-10 3.2.4 Patient circuits resistance ... 3-11 4. OXYGEN SUPPLY_ 4-12 4.1 Description ... 4-12 4.1.1 Precision ... 4-12 4.1.2 Eole 3 S ... 4-12 4.1.3 Eole 3 XLS ... 4-13 5. VENTILATION PARAMETERS REMINDER_ 5-14 5.1 Ventilation parameters table ... 5-14 5.2 Adjustment parameters list ... 5-15 5.3 Measured parameters list ... 5-17 5.4 Pressure display ... 5-18 6. ALARMS RELEASING PROCEDURES_ 6-19 6.1 Power supply alarm ... 6-19 6.2 Temporarily stoppable alarms requiring rapid reaction ... 6-19 6.3 Unstoppable and potentially fatal alarms requiring immediate action6-19 6.4 Unstoppable and potentially fatal microcontroller alarm requiring immediate action ... 6-20 7. TROUBLESHOOTING ALARMS_ 7-21 7.1 POWER SUPPLY ALARM ... 7-21 7.2 TEMPORARILY STOPPABLE ALARMS ... 7-21 7.3 UNSTOPPABLE ALARMS ... 7-23 7.4 UNSTOPPABLE MICROCONTROLLER ALARM ... 7-24 8. DISINFECTING_ 8-25 8.1 Maintenance Frequency ... 8-25 8.2 Decontamination and disinfecting procedures ... 8-25 8.2.1 Patient circuit ... 8-25 8.2.2 Removable pneumatic block ... 8-26 8.2.3 Humidifier chamber ... 8-29 8.2.4 Bacteria filter ... 8-29 8.2.5 External unit parts ... 8-29 9. MAINTENANCE AND PREVENTIVE INSPECTIONS_ 9-30 9.1 Pneumatic circuit checks ... 9-30 9.1.1 EOLE3S ... 9-30 9.1.2 EOLE3XLS ... 9-31 9.2 Electrical circuit checks ... 9-31 9.2.1 Checking the LEDs and power source switching ... 9-31 9.2.2 Checking the fuses ... 9-32 9.2.3 Checking the internal batteries ... 9-32 9.2.4 Checking the electrical accessories ... 9-33 9.2.5 The oxygen cell (optional) ... 9-33 9.3 Checking alarms ... 9-34 9.4 Checking the batteries autonomy ... 9-35 10. TECHNICAL INSPECTIONS AND SETTINGS_ 10-36 10.1 Checking the run-ends ... 10-36 10.2 Checking the mechanical system ... 10-36 10.2.1 Checking the drive belt ... 10-36 10.2.2 Checking the motor brushes ... 10-36 10.3 Checking the voltages ... 10-37 10.4 Checking the charge voltage ... 10-37 10.5 Setting the display contrast ... 10-37 10.6 Accessing the technical menu ... 10-37 10.7 Peep option ... 10-38 FUNCTIONAL DIAGRAM: THE PNEUMATIC CIRCUITS _ 11-39 12. TECHNICAL SPECIFICATIONS: VENTILATOR_ 12-44 12.1 Power supply ... 12-44 12.2 Battery runtime ... 12-44 12.3 Electrical interfaces ... 12-44 12.4 Performances ... 12-45 12.5 Conditions of use ... 12-46 12.6 Storage conditions ... 12-46 12.7 Transport conditions ... 12-47 12.8 Materials used ... 12-47 12.8.1 Materials in contact with the inspired air ... 12-47 12.8.2 Materials in contact with the oxygen ... 12-47 12.9 Settings, Measures and Alarms ranges ... 12-48 12.9.1 Settings ... 12-48 12.9.2 Alarms ... 12-48 12.9.3 Measurements ... 12-48 12.10 Humidification ... 12-49 12.11 Fire prevention ... 12-49 12.12 Applied standards ... 12-49 13. TECHNICAL SPECIFICATIONS FOR THE ACCESSORIES AND THE MAINTENANCE PRODUCTS_ 13-50 13.1 Pneumatic circuits ... 13-50 13.2 Humidifier ... 13-50 13.3 Bacteria filter ... 13-51 13.4 Gas input filter ... 13-51 13.5 Remote alarm box ... 13-51 13.6 Remote control ... 13-52 13.7 Removable XLS battery pack ... 13-52 13.8 External DC power supply ... 13-52 13.9 Flow sensor: Pitot tubes ... 13-52 13.10 Integrating oxygen balloon ... 13-53 13.11 Oxygen sensor ... 13-53 13.12 Technical properties of BACTINYL® ... 13-53 13.12.1 Instrumentation liquid soap ... 13-53 13.12.2 Disinfecting BACTI NYL® 5M ... 13-54

show more

Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image