Fluke 75 Series II Digital multimeter
Manufacturer:
No picture available!
Maybe you can upload a pic for the
Fluke 75 Series II ?
If you have any other manuals for the
Fluke 75 Series II you can upload the files here .
Model:
75 Series II
Date:
1997
Category:
Group:
Description:
Information
Maximum Voltage Between any Terminal and Earth Ground
1000V de, 750V ac rms(sine)
Fuse Protection 300 mA. 630 mA, 250V Fast Fuse
10A. 15A, 600V Fast Fuse
Display Digital: 3,200 counts, updates 2.5/sec
Analog: 32 segments, updates 25/sec
Response Time of Digital Display
V ac < 2 s
V do < 1 s
Ω < 1 s to 320 ΚΩ, < 2 s to 3.2 ΜΩ, < 10 s to 32 ΜΩ
Operating Temperature 0°C to 50°C
Storage Temperature -40°C to 60°C
Temperature Coefficient 0.1 x (specified accuracy)/°C (<18°C
or >28°C)
Electromagnetic Compatibility - In an RF field of 3 V/m on
all ranges and functions:
Total Accuracy * Specified Accuracy +1.1% of range
Relative Humidity
Except 32 ΜΩ Range:
Only:
Battery Type Battery Life
Continuity Beeper Shock, Vibration Size (HxWxL)
Weight
Safety
0% to 90% (0°C to 35°C)
0% to 70% (35°C to 50°C)
0% to 80% (0°C to 35°C)
0% to 70% (35°C to 50°C)
9V, NEDA 1604 or 6F22 or 006P 2000 hrs typical with alkaline
1600 hrs typical with carbon zinc 4096 Hz
Per MIL-T-28800 for a Style B, Class 2 Instrument
2.8 cm x 7.5 cm x 16.6 cm (1.12 in x 2.95 in x 6.55 in)
340g (12oz)
Designed to Protection Class II per IEC 348, ANSI/ISA-S82,
UL1244, and CSA C22.2 No.231
Manual type:
User Manual
Pages:
37
Size:
8.25 Mbytes (8646768 Bytes)
Language:
english, german, french
Revision:
2
Manual-ID:
896191
Date:
Quality:
Scanned document, all readable.
Upload date:
10 February 2016
MD5:
dd372c97e844cd875a496deb4ec141f3
Downloads:
5011
Information
WHAT IS IN THIS MANUAL ... 1
SAFETY INFORMATION ... 2
SYMBOLS ... 4
ROTARY SWITCH ... 5
INPUT
JACKS ... 6
PUSHBUTTON ... 8
Autorange ... 8
® Manual Range ... 6
® Automatic Touch Hold Mode ... 10
DIGITAL DISPLAY ... 12
BAR
GRAPH ... 12
STANDBY ... 12
TAKING MEASUREMENTS ... 14
V Measuring Voltage ... 14
Π Measuring Resistance ... 16
»DI Testing
Continuity ... 17
-μ- Testing
Diodes ... 18
A Testing
Current ... 20
HOLSTER ... 22
MAINTENANCE ... 23
Internal Fuse Test ... 24
Replacing the Battery and Fuse(s) ... 25
Service & Parts ... 26
SPECIFICATIONS ... 28
SERVICE CENTERS ... 34
Add Comment
Terms and Conditions
These terms and conditions contain rules about posting comments. By submitting a comment, you are declaring that you agree with these rules:
- Although the administrator will attempt to moderate comments, it is impossible for every comment to have been moderated at any given time.
- You acknowledge that all comments express the views and opinions of the original author and not those of the administrator.
- You agree not to post any material which is knowingly false, obscene, hateful, threatening, harassing or invasive of a person's privacy.
- The administrator has the right to edit, move or remove any comment for any reason and without notice.
Failure to comply with these rules may result in being banned from further commenting.
These terms and conditions are subject to change at any time and without notice.
Comments