Equipment information

Kikusui Electronics Corporation 538 Oscilloscope
Manufacturer
Kikusui Electronics Corporation
Model 538
Date
Category Measurement instruments
Group Oscilloscope
Description Universal Purpose Oscilloscope
Information
                                    The Model 538 is a compact, highly reliable, universal
purpose Oscilloscope which employs compact 75mm round screen
cathode-ray tube, solid-state electronics, and unique light
weight metallic alloy housing

The vertical system provides a sensitivity of 1 0 mV/div or
over and a frequency bandwidth of DC~ 1.5 MHz. It has a
direct CRT input terminal.

The time axis circuit provides sweep frequencies of 10 Hz ~
100 kHz sweep and synchronizing with INT M - ” only. When
this circuit is switched over to the external sweep mode, it
provides a deflection sensitivity of 250 mV/d or over and a
frequency band of DC ~ 500 kHz. The external signal is
applicable through a front panel terminal. This mode can be
employed for X - Y operation of the Oscilloscope, providing
a high operation flexibility.

Since solid-state, electronics is employed throughout the
circuits, the Oscilloscope can start operating only in less
than 20 seconds after its power is turned on. Since
heat-generating components and hence the instrument wattage
are minimized, the drift is very small and an improved
operation reliability is__attained.

These manuals are available for the above equipment:

Manual Type User Manual Kikusi-9478-Manual-Page-1-Picture
Pages 23
Size 915.68 Kbytes (937655 Bytes)
Language english
Revision
Manual-ID/Number
Date
Quality Scanned document, all readable.
Upload date
MD5 2144de9dba80810ae60ecb1fbe4a1b86
Downloads 92 since 02 September 2017
Information
1.	GENERAL  ...  1

2.	SPECIFICATIONS  ...   ...  2

3.	EXPLANATION OF -PANEL  ...   ...  4

4.	OPERATING PROCEDURE  ... • ...  8

4-1 First Operation  ...  8

4-2	• Application  ... * ...  9

5.	CAUTION ON OPERATION  ... 12

5-1	Supply Line Voltage  ... ' ... 12

5-2 Fuse  ... 12

5	- 3 Ambient Temparature  ... 12

5-4 Maximum Input Voltage  ... 12

5-5 Life of the CRT  ... 13

5-6	Maximum Input Voltage to EXT HORIZ IN Terminal without
Distortion of Waveform  ... 13

6.	MAINTENANCE AND CALIBRATION  ...  14

6	- 1 Case Removal  ...   ...  14

6-2	Change of Supply Line Voltage • • •  ... 14

6-3 Exchange of the Fuse  ... 14

6-4 Adjustment of DC Balance  ... 14

6 -.5 Phase Compensation for VERT GAIN switch	----- 15

6-6	Adjustment of High Frequency Response Compensation

of the Vertical Amplif ier ...   ... 15

6-7 Adjustment of Horizontal DC Balance • •  ... 16

.6-8 Adjustment of Trace Alignment  ...  16