California Instruments 503T Power supply
Manufacturer:
No picture available!
Maybe you can upload a photo for the
California Instruments 503T ?
If you have any other manuals for the
California Instruments 503T you can upload the files here .
Model:
503T
Date:
1986
Category:
Group:
Description:
Power Source
Information
The California Instruments Model 503T is a solid state, high
performance, low distortion power source that provides up to
500 VA the three phase power when used with the proper
California Instruments Oscillator. The Model 503T Three
Phase Power Source is illustrated in Figure 1- 1. Full power
output is available in five different voltage ranges and
over the frequency range from.45 Hz to 5 KHz. The output
voltage range is normally determined at the factory prior to
shipment of the unit, however it can be accomplished in the
field, if required. The full power ranges are;
1) 23, 4 to 30 volts rms line-to-neutral in a three phase
output configuration. This provides 40* 5 volts to 52 volts
rms line-to-line at 167 VA per phase (500 VA total).
2) 35. 1 to 45 volts rms line-to-neutral in a three phase
output configuration. This provides 60. 6 volts to 78 volts
rms line-to-line at 167 VA per phase (500 VA total).
3) 58. 5 to 75 volts rms line - to-neutral in a three phase
output configuration. This provides 102 volts to 130 volts
rms line-to-line at 167 VA per phase (500 VA
..........total)...,.......................................................................................................
4) 105 to 135 volts rms line-to-neutral in a three phase
output configuration. This provides 182 volts to 234 volts
rms line-to-line at 167 VA per phase (500 VA total).
5) 105 to 135 volts rms single phase output at 500 VA.
The serial number tag, located on the rear of the Model 503T
Power Source, indicates the output voltage range which the
unit is wired for at the time of shipment.
Manual type:
Service and User Manual
Pages:
84
Size:
2.87 Mbytes (3006313 Bytes)
Language:
english
Revision:
J
Manual ID:
4053-960
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
2015 12 20
MD5:
59d877f3b0dcdbbc0487a16cb94a1250
Downloads:
581
Information
GENERAL DESCRIPTION
1.1 INTRODUCTION 1
1. 2 GENERAL DESCRIPTION 1
1.3 ACCESSORY EQUIPMENT 2
INSTALLATION AND OPERATION
2.1 UNPACKING 7
2.2 POWER REQUIREMENTS 7
2. 3 CIRCUIT BREAKER REQUIREMENTS 8
2.4 OUTPUT VOLTAGE RANGE 8
2.5 METER RANGE 10 2„ 6 ACCEPTANCE TEST PROCEDURE 10 2* 7
MECHANICAL INSTALLATION 11
2.8 INPUT POWER WIRING 12
2.9 OUTPUT POWER WIRING 12
2. 10 FRONT PANEL CONTROLS 12 2* 11 OPERATION OVER EXTENDED
FREQUENCY RANGE I2A
THEORY OF OPERATION
3.1 GENERAL 13
3. 2 DETAILED CIRCUIT DESCRIPTION 15
CALIBRATION PROCEDURE
4.1 ... GENERAL 21 4* 2 TEST EQUIPMENT REQUIRED 23
47 3 ... INITIAL
ADJUSTMENTS ... 23
4. 4 OVERLOAD ADJUSTMENT 25 4. 5 GAIN ADJUSTMENT 27 4. 6 AC
LINE INPUT POWER 27 4. 7 OUTPUT VOLTAGE, POWER OUTPUT AND
HARMONIC DISTORTION 2?
4. 8 ■ LINE REGULATION 28
4, 9 LOAD REGULATION ADJUSTMENT 30
4. 10 AMPLITUDE STABILITY 31
4. 11 FREQUENCY RESPONSE 32
4„ 12 AC NOISE LEVEL 32
4. 13 0. 7 LAGGING POWER FACTOR 33
4„ 14 0.7 LEADING POWER FACTOR 36
4. 15 PHASE ACCURACY 3o
MAINTENANCE AND TROUBLESHOOTING
5. 1 GENERAL 38
5.2 TROUBLESHOOTING 38
CIRCUIT DIAGRAM
6. 1 GENERAL 39
6. 2 REFERENCE DESIGNATIONS 39
REPLACEABLE PARTS
7.1 GENERAL 40
7.2 ORDERING INFORMATION 40
PARTS LIST .
APPENDIX A
CODE LIST OF MANUFACTURERS