‘ GENERAL
• Frequency coverage : 156.525 MHz (Ch 70) Rx only
• Mode : 16K0G2B
• Power supply requirement : 13.8 V DC (negative ground)
• Usable temperature range : –20°C to +60°C
• Current drain (at 13.8 V DC) : 1.0 A (approx.)
• Antenna impedance : 50 Ω (nominal)
• Output impedance (for testing) : 100 kΩ (nominal)
• Dimensions (projections not included) : 165(W)×110(H)×78(D) mm
• Weight : 1 kg (approx.)
‘ RECEIVER
• Receive system : Double conversion superheterodyne system
• Intermediate frequencies : 1st 21.7 MHz
2nd 450 kHz
• Sensitivity : -10 dBμ typical at 12 dB SINAD
• Adjacent channel selectivity : 70 dB
• Spurious response : 70 dB
• Intermodulation rejection ratio : 68 dB
• Hum and noise : –40 dB
1 Manual
Service manual
Manual type:
Service manual
Pages:
26
Size:
2.8 MB
Language:
english
Revision:
Manual-ID:
S-13702HZ-CD
Date:
Quality:
Electronic document, no scan, very well readable.
Upload date:
April 8, 2012
MD5:
17ced7bd-7acd-6b5b-f3b4-b0489a0c522e
Downloads:
959