Fluke - PM 6303A - LCR Meter
Manufacturer:
Equipment:
PM 6303A
Date:
1995
Category:
Group:
Sub Group:

Information

MAIN FEATURES The PM6303A Automatic RCL Meter is used for precise measurements of resistance, capacitance and inductance. The instrument provides auto-function and auto-ranging facility. It allows fast and high precision measurements of passive Components over a wide range. The component to be measured is connected to the instrument via front panel test posts, the PM 9541A four-wire test cable, or the PM 9542A four-terminal test adapter. The Adapter PM 9542SMD or the PM 9540/7WE SMD Tweezers for surface-mounted Components are also available. The measurement result, the numerical value, dimension, and the equivalent circuit symbol, is immediately displayed on the large four-digit liquid-crystal display (LCD), which is updated at a rate of two measurements per second. A microprocessor controls the measurement process, computes the measurement value, and transfers the result to the display. In the AUTO mode the dominant parameter, either R, C, or L of the component under test is automatically selected for display. For example, for an inductance with a quality factor Q between 1 and 500, the instrument indicates the measurement value of the series inductance and as equivalent circuit symbol, the series connection of a resistance and an inductance. In addition to the AUTO mode, eight component parameters can be selected manually by pressing pushbuttons: ■ Quality factor Q ■ Dissipation factor D ■ Parallel resistance Rp ■ Series resistance Rs ■ Impedance Z ■ Parallel capacitance Cp or parallel inductance Lp ■ Series capacitance Cs or series inductance Ls ■ Phase angle An internal DC BIAS voltage can be added to the measurement voltage for electrolytic capacitors. The PM6303A RCL Meter is especially suited for use in laboratories, for quality control, in service workshops, and for educational purposes.

show more

3 Manuals

User manual
Manual type:
User manual
Pages:
90
Size:
1.7 MB
Language:
english
Revision:
Manual-ID:
951111
Date:
January 1995
Quality:
Scanned document, all readable.
Upload date:
Jan. 20, 2018
MD5:
5fd0504e-e986-6009-2a39-3916d833d259

Information

SHIPMENT NOTE AND INITIAL INSPECTION 1 INSTALLATION AND SAFETY INSTRUCTIONS 1 - 1 1.1 SAFETY INSTRUCTIONS ' 1 - 1 1.1.1 Maintenance and Repair 1 - 1 1.1.2 Grounding (Earthing) 1-2 1.1.3 Connections 1 - 2 1.1.4 Line Voltage Setting and Fuses •I _ 3 1.2 OPERATING POSITION OF THE INSTRUMENT 1 “4 1.3 RADIO INTERFERENCE SUPPRESSION • 1—4 2 MAIN FEATURES 2 - 1 3 OPERATING INSTRUCTIONS 3 - 1 3.1 GENERAL INFORMATION 3 _ 1 3.2 TURNING THE INSTRUMENT ON 3 - 1 3.3 SELF-TEST ROUTINE 3 - 1 3.4 BRIEF CHECKING PROCEDURE 3-2 3.4.1 General 3-2 3.4.2 Functional Test 3-3 3.5 OPERATION AND APPLICATION 3-5 3.5.1 Control Elements, Display and Connections 3-5 3.5.2 Measurement Setup and Accessories 3-8 3.5.3 Automatic Zero Trim 3-13 3.5.4 Component Measurement 3-15 3.5. Out-of-Range and Error Messages 3-17 3.5.6 Component Measurement at Range Limits 3-18 3.6 MEASUREMENT PRINCIPLE 3-21 3.7 SELF DIAGNOSTICS 3-27 4 CHARACTERISTICS 4-1 4.1 SAFETY AND EMC REQUIREMENTS 4 - 1 4.2 PERFORMANCE SPECIFICATIONS 4-2 4.3 Power Supply 4-6 4.4 ENVIRONMENTAL CONDITIONS 4-6 4.5 SAFETY & QUALITY DATA; CABINET 4-8 4.6 Accessories 4-9 5 PERFORMANCE TEST 5.1 INTRODUCTION 5.2 RECOMMENDED TEST EQUIPMENT 5.3 SELF-TEST ROUTINE, ERROR MESSAGES 5.4 PERFORMANCE VERIFICATION 5.4.1 Measurement Voltage 5.4.2 Measurement Frequency 5.4.3 Open-Circuit Trimming 5.4.4 Short-Circuit Trimming 5.4.5 Resistor Measurement 5.4.6 Capacitance/Inductance Measurement 6 LIMITED WARANTY & LIMITATION OF LIABILITY, DECLARATION OF CONFORMITY 6 - 1 INSTALLATION AND SAFETY INSTRUCTIONS IN FOREIGN LANGUAGES FIGURES Fig. 1 Front view Fig. 2 Rear view Fig. 3 PM 9540/TWE, SMD Tweezers Fig. 4 PM 9540/BAN, 4-wire test cable with banana plugs Fig. 5 PM 9541 A, 4-wire test cable Fig. 6 Single and double test posts Fig. 7 PM 9542SMD, SMD Adapter Fig. 8 PM 9542A, RCL Adapter

show more

Downloads:
1147
Last month downloads:
4
Download fluke--pm-6303a--user--ID10142.pdf
User manual
Manual type:
User manual
Pages:
247
Size:
18.3 MB
Language:
english
Revision:
2
Manual-ID:
4822 872 10158
Date:
February 1999
Quality:
Scanned document, all readable.
Upload date:
Jan. 28, 2018
MD5:
8ed68150-085b-4d12-5b02-9026e1018ea1

Information

1 INSTALLATION AND SAFETY INSTRUCTIONS 1.1 SAFETY INSTRUCTIONS 1.1.1 Maintenance and Repair 1.1.2 Grounding (Earthing) 1.1.3 Connections 1.1.4 Line Voltage Setting and Fuses 1.2 OPERATING POSITION OF THE INSTRUMENT 1.3 RADIO INTERFERENCE SUPPRESSION 2 MAIN FEATURES 3 OPERATING INSTRUCTIONS 3.1 GENERAL INFORMATION 3.2 TURNING THE INSTRUMENT ON 3.3 SELF-TEST ROUTINE 3.4 BRIEF CHECKING PROCEDURE 3.4.1 General 3.4.2 Functional Test 3.5 OPERATION AND APPLICATION 3.5.1 Control Elements, Display and Connections 3.5.2 Measurement Setup and Accessories 3.5.3 Automatic Zero Trim 3.5.4 Component Measurement 3.5. Out-of-Range and Error Messages 3.5.6 Component Measurement at Range Limits 3.6 MEASUREMENT PRINCIPLE 3.7 SELF DIAGNOSTICS 4 CHARACTERISTICS 4 - 1 4.1 SAFETY AND EMC REQUIREMENTS 4 - 1 4.2 PERFORMANCE SPECIFICATIONS 4-2 4.3 Power Supply 4-6 4.4 ENVIRONMENTAL CONDITIONS 4-6 4.5 SAFETY & QUALITY DATA; CABINET 4-8 4.6 Accessories 4-9 5 PERFORMANCE TEST 5-1 5.1 INTRODUCTION 5 - 1 5.2 RECOMMENDED TEST EQUIPMENT 5-1 5.3 SELF-TEST ROUTINE, ERROR MESSAGES 5-2 5.4 PERFORMANCE VERIFICATION 5-2 5.4.1 Measurement Voltage 5-2 5.4.2 Measurement Frequency 5-3 5.4.3 Open-Circuit Trimming 5-3 5.4.4 Short-Circuit Trimming 5-4 5.4.5 Resistor Measurement 5-4 5.4.6 Capacitance/Inductance Measurement 5-5 6 LIMITED WARANTY & LIMITATION OF LIABILITY, DECLARATION OF CONFORMITY 6 - 1 INSTALLATION AND SAFETY INSTRUCTIONS IN FOREIGN LANGUAGES FIGURES Fig. 1 Front view Fig. 2 Rear view Fig. 3 PM 9540/TWE, SMD Tweezers Fig. 4 PM 9540/BAN, 4-wire test cable with banana plugs Fig. 5 PM 9541 A, 4-wire test cable Fig. 6 Single and double test posts Fig. 7 PM 9542SMD, SMD Adapter Fig. 8 PM 9542A, RCL Adapter SERVICE CENTERS

show more

Downloads:
945
Last month downloads:
9
Download fluke--pm-6303a--user--ID10173.pdf
Datasheet
Manual type:
Datasheet
Pages:
5
Size:
81.4 KB
Language:
english
Revision:
Manual-ID:
Date:
1998
Quality:
Electronic document, no scan, very well readable.
Upload date:
Jan. 21, 2023
MD5:
b17e53de-4eb3-f354-7d14-e8a3e6897cdd
Downloads:
1011
Last month downloads:
34
Download fluke--pm-6303a--datasheet--ID13898.pdf