Fluke - 5440B - Calibrator
Manufacturer:

Image 1 of 2
If you have any other photos or manuals for the
Fluke 5440B
you can
upload the files here.
Equipment:
5440B
Date:
1986
Category:
Group:
Sub Group:
Information
The 5440B and 5442A are equipped with bright
vacuum-fluorescent displays for clear visibility at any
viewing angle. Even inexperienced operators find the 5440B
and 5442A easy to use because the 40-character, alphanumeric
display provided in addition to the numeric output display,
makes operating instructions and error messages clear and
readable in engineering units and English language messages
instead of coded numerics. For semi-automated testing, the
5440B allows a complete test sequence of up to 60 steps to
be stored in the internal Procedure Storage memory and
recorded for later use in the interchangeable, plug-in
Procedure Storage Modules. A test sequence is recalled and
executed one step at a time with each touch of the NEXT STEP
key.
The differences between the 5440B and the 5442A are in the
operating features and specifications. The 5440B comes
equipped with the Procedure Storage Module capability and
boost capability for driving the 5205A Precision Power
Amplifier and 5220A Transconductance Amplifier in system
applications. The rear output terminals found on the 5440B
as a standard feature are available for the 5442A as an
option. Both instruments have outstanding accuracy
specifications and the capability for operating at full
rated accuracy over a temperature range of ±5°C from the
calibration temperature, making them well-suited for
operation in a production environment as well as in a
standards lab. Both instruments are completely programmable
via the GPIB/IEEE-488* interface which is included at no
extra cost.
The outstanding accuracy specifications for the 5440B and
5442A are easily maintained in any lab by performing the
simple, automatic calibration procedures which store the
calibration constants in non-volatile solid-state memory. No
hardware adjustments are required. The Fluke 732A Reference
Standard combined with the Fluke Direct Volt Maintenance
Program and the Fluke 752A Reference Divider, provide the
highest accuracy reference standards available for this
periodic calibration.
2 Manuals
Datasheet
Manual type:
Datasheet
Pages:
2
Size:
303.5 KB
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Scanned document, reading partly badly, partly not readable.
Upload date:
Jan. 28, 2016
MD5:
13ba8023-4f86-b808-43d0-7f0214318354
Downloads:
1230
Service manual
Manual type:
Service manual
Pages:
364
Size:
13.7 MB
Language:
english
Revision:
Manual-ID:
804005
Date:
December 1986
Quality:
Scanned document, all readable.
Upload date:
Jan. 12, 2018
MD5:
c86ff38e-54a2-0e05-57a5-b142b2b363d8
Information
The 5440 Series Service Manual documents the 5440B/5442A
Direct Voltage Calibrators. The Service Manual includes a
theory of operation, general maintenance procedures,
performance tests, calibration procedures, troubleshooting
information, a list of replaceable parts, and schematic
diagrams. The Service Manual, however, does not document the
5440A Calibrator.
For information regarding the 5440A Calibrator, refer to the
5440A Service Manual (P/N 611683),
Downloads:
875