Whirlpool ADG 954/2 Dish washer
Manufacturer:
Image 1 of 4
Image 2 of 4
Image 3 of 4
Image 4 of 4
If you have any other photos or manuals for the
Whirlpool ADG 954/2 you can upload the files here .
Model:
ADG 954/2
Date:
1999
Category:
Group:
Description:
Information
Technical data
Dimension
Height 82 cm
Width 44.8 cm
Depth 57 cm
Weight 45 kg
Wooden door
Thickness min.. 16 mm
Thickness max. 25 mm
Width min. 445 mm
Width max. 450 mm
Height min. 650 mm
Height max. 720 mm
Weight min. 2.5 kg
Weight max. 6.2 kg
Max. stick out over lower
edge of appliance door 90 mm
Specification / PI-Expression (norm. Progr.)
Detergent 25 gr
Saltconsumption
by 21 °deg d.H. 28 gr
Water connection up to 60 °C
Capacity 9 stand. place settings
Volume
Water
Working-level 3.75 l
Safety-level
- motor on 9.5 l
- motor off 6.5 l
Overflow-level 6.2 l
Detergent 5+25 gr
Clear rinse containing 120 ccm
Rinse dosage per step 1 ccm
Salt container volume 1.35 kg
Flow rates / Inlet volumes
Spray pump ~ 50 l/min
Drain pump ~ 15 l/min
Water inlet electrovalve ~ 3.75 l/min
Water pressure
Inlet pressure min. 0.3 bar
Spraypump pressure 0.3 bar
Rotations
SP-Motor 2680 RPM
DP-Motor 2500 RPM
Spray arm lower 57 5 RPM
Spray arm upper 24 5 RPM
Electrical Data
Base level
Voltage 220/230 V
Frequency 50 Hz
Total power 2200 W
Fuses 10 A
Timer
Model Eaton EC 4727
Basic step times 15“-30’’-45“-1’-2’-4’
Steps 60
Heating
Throughflow system
Voltage 220/230 V
Total power 2.05 kW
Resistance 27 W
Motor
Spraypumpmotor
Voltage 220/230 V
Power consumption 150 W
HI 38 W
HA 40 W
Capacitor 6 F
To loos spraypump
from motor turn anti clockwise
To fit spraypump
on motor turn clockwise
needed racket spanner 6 mm
Drainpumpmotor
Voltage 220/230 V
Power consumption 23 W
Resistance 200 W
Timer Motor
Voltage 220/230 V
Power consumption 3.5 W
Resistance 6450 W
Valve
Inlet valve
Voltage 220-240 V
Power consumption 6 W
Resistance 3750 W
Regeneration valve
Voltage 220-240 V
Power consumption 6 W
Resistance 3750 W
Safty system against water-leakage
Aquastop + floater switch
Floter switches of the inlet valve and on the drain
pump
Thermostates
Double thermostat in the Door
NA58
Color code grey
Temperature 58 °C
closes when temperature is reached
NC72
Color code red
Temperature 72 °C
opens when temperature is reached
Double thermostat in the Door
NA38
Color code white
Temperature 38 °C
closes when temperature is reached
NC45
Color code red
Temperature 48 °C
opens when temperature is reached
Water measuring
Remove the coases sieve, put into the sump a
meassuring meter, look the height of the water
level
Working level 110 mm
Safety level 125 mm
Pressostat
Working level
Niveau 80/60 3 mm
Safety level (against overflow)
Niveau 125/75 3 mm
High pressure pressostat (against heating without
water)
Niveau 2400/1500mm
Manual type:
Service Manual
Pages:
13
Size:
361.81 Kbytes (370495 Bytes)
Language:
english
Revision:
Manual ID:
4812 718 14121
Date:
1999 03 15
Quality:
Electronic document, no scan, very well readable.
Upload date:
2013 10 03
MD5:
24e23f13437e08981a8cfc82a1dcf56f
Downloads:
3744
Information
This documentation is only intended for qualified technicians who are aware of the respective
safety regulations.
Technical data 2 - 4
Spare part list 5 - 6
Exploded view 7 - 10
Wiring diagram 11
Circuit diagram 12
Program diagram 13
Manual type:
Service Manual
Pages:
13
Size:
353.59 Kbytes (362077 Bytes)
Language:
english
Revision:
Manual ID:
4812 718 14797
Date:
1999 11 09
Quality:
Electronic document, no scan, very well readable.
Upload date:
2013 10 03
MD5:
f087e7084f6f4aa914c2426be5c2098a
Downloads:
2751
Information
This documentation is only intended for qualified technicians who are aware of the respective
safety regulations.
Technical data 2 - 4
Spare part list 5 - 6
Exploded view 7 - 10
Wiring diagram 11
Circuit diagram 12
Program diagram 13