Weinmann MODUL CapnoVol WM 22400 Spirometer
Hersteller:
Modell:
MODUL CapnoVol WM 22400
Datum:
2009
Kategorie:
Gruppe:
Beschreibung:

Information

MODUL CapnoVol is a device for measuring respiratory parameters on exhalation. The following are shown as figures: • tidal volume (TVe) • minute volume (MVe) • respiratory frequency (AF) • ratio of inspiration to exhalation (I:E) • carbon dioxide concentration at the end of exhalation (etCO2) The following is shown in the form of a graph: • current carbon dioxide concentration (capnogram). MODUL CapnoVol can be used in a permanent location or on a mobile basis both indoors and outdoors.

mehr

Serviceanleitung
Dokumenttyp:
Serviceanleitung
Seiten:
44
Größe:
3.14 Mbytes (3290779 Bytes)
Sprache:
english
Revision:
Dokument-ID:
WM 16829a
Datum:
01 Januar 2009
Qualität:
Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
28 Februar 2018
MD5:
938d0fb46b3dd41159517f154d11f03d
Downloads:
613

Information

Introduction ... 3 1. Overview ... 4 2. Description of device ... 5 2.1 Intended purpose ... 5 2.2 Description of function ... 5 3. Hygiene treatment ... . 6 3.1 Intervals ... . 6 3.2 MODUL CapnoVol and sensor cable . 6 3.3 Individual parts ... . 7 4. Test the device ... 8 4.1 Test material required ... 8 4.2 Preparation for testing ... 8 4.3 Enter device data ... 9 4.4 Test leaktightness ... 9 4.5 Test device self-test ... 10 4.6 Test the infrared interface ... 10 4.7 Test display elements ... 10 4.8 Test input elements ... 11 4.9 Test battery charging ... 11 4.10 Test flow measurement ... 12 4.11 Test occlusion alarm ... 12 4.12 Test CO2 measurement ... 13 4.13 Test system clock ... 14 4.14 Documentation ... 14 5. Servicing ... . 15 5.1 Intervals and scope ... . 15 5.2 Change battery ... . 16 5.3 Change O-rings of plug connection. . 16 5.4 Change O-rings of oxygen duct inlet . 17 5.5 Calibrate O2 sensor ... . 17 5.6 Storage ... . 19 5.7 Disposal ... . 19 6. Troubleshooting ... 20 7. Repair information and repair instructions 22 7.1 General ... . 22 7.2 Open the device ... . 22 7.3 Close the device ... . 23 7.4 Replace the Capno connecting adapter ... . 24 7.5 Replace Nafion tube ... . 25 7.6 Replace main circuit board and/or CAP 100 circuit board ... . 25 7.7 Replace fuses ... . 28 7.8 Replace connecting tube for oxygen duct ... . 29 7.9 Replace display circuit board ... . 31 7.10 Replace infrared circuit board ... . 32 7.11 Replace top part of housing ... . 34 8. Replacement parts ... 35 8.1 Replacement parts list ... 35 8.2 Parts to be changed when servicing . 36 9. Tools and testing equipment ... . 37 9.1 General tools ... . ... . 37 9.2 Special tools ... . ... . 37 9.3 Testing equipment . . . ... . 38 10. Technical data ... 39 11. Service record ... 41

mehr

Kommentare

Noch keine Kommentare, sei der erste Poster!

Kommentar hinzufügen

* Pflichtfeld
1000
Captcha Image