Thurlby Thandar Instruments TTI HA1600 Sonstiges
Hersteller:
Kein Bild verfügbar!
Vielleicht kannst du ein Bild für
Thurlby Thandar Instruments TTI HA1600
hochladen ?
Wenn du andere Handbücher für ein
Thurlby Thandar Instruments TTI HA1600 hast,
kannst du die Dateien hier hochladen .
Modell:
HA1600
Datum:
2007
Kategorie:
Gruppe:
Beschreibung:
Information
High performance power analyser
The HA1600 is a high speed, high accuracy AC power analyser for single phase supplies of up to
16 Amps rms.
The supply to be measured is connected via a dedicated input cable independently of the supply
to the instrument. The output to the load is via a front panel mounted 'standard' mains connector.
A wide range of power connectors is available including most European national types.
The HA1600 can measure Watts, VA, Volts rms, Volts peak, Amps rms, Amps peak, Crest factors,
THD, Power factor, Frequency and Inrush current.
The large display can show multiple parameters simultaneously along with graphical
representations of voltage and current waveforms.
Dual 16 bit Analog to Digital converters continuously sample both voltage and current and give a
wide dynamic range. A fast Digital Signal Processor gives the performance needed for continuous
real-time analysis of the data. Advanced algorithms yield accurate results, using extended
precision or floating point arithmetic wherever necessary.
Compliance-quality harmonics analyser
The HA1600 has been designed to make harmonics measurements both quick and simple.
It measures harmonics from the 1st to the 40th and updates the display in real time.
It is suitable for pre-compliance measurements using a normal mains supply and is capable of full
compliance measurements to EN61000-3-2 in conjunction with a suitable power source (such as
the(AC1000).
Capabilities include continuous monitoring of the supply voltage, continuous comparison to
harmonic limits and timed test sequences with analysis of fluctuating harmonics.
Compliance-quality flicker meter
The HA1600 has the capability to operate as a compliance quality voltage variation and flicker
meter in conformance with EN61000-3-3 and EN61000-4-15.
Flicker severity can be measured in terms of Pst and Plt while simultaneously performing full
analysis of voltage variations, including the calculation of the maximum value dmax, the difference
between steady states dc and the change characteristic d(t).
For pre-compliance testing, a current measurement method can be used, rather than voltage
measurement, to eliminate the need for a clean power Generator and a reference impedance.
A full range of interfaces
A parallel printer Interface is included, for record keeping and archiving, and also a high speed
RS-232 Interface is provided for use with either a printer or remote control Software running on a
PC. The HA1600A also has a USB port for use with the HA-PC Link Plus Software.
The internal Software of the instrument is stored in flash memory and can be updated through the
serial port as the requirements of the measurement standards evolve.
HA1600 and HA1600A
The two versions of the instrument are in different cases, with slightly different front panel layouts.
The HA1600A has a USB port. In all other respects the operation and performance of the two
types is identical. Both use the same firmware, and this manual applies to either type if fitted with
firmware version 2.80 or late
Dokumenttyp:
Bedienungsanleitung
Seiten:
58
Größe:
1.27 Mbytes (1332012 Bytes)
Sprache:
english
Revision:
Issue 9
Dokument-ID:
48511-0400
Datum:
Qualität:
Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
02 November 2013
MD5:
8720c545ae434476f6a32ae450a18559
Downloads:
571
Information
Introduction 2
Specification 3
Safety 5
EMC 7
Installation 8
Connections 9
Front Panel Connections 9
Rear Panel Connections 9
Initial Operation 10
Power Meter View 12
Power Meter Set-up 14
Waveform Graph View 15
Waveform Graph Set-up 16
Harmonics View 19
Harmonics View Set-up 20
Display Format - Histogram 20
Display Format – Tables 23
Test Control View 25
Test Control Set-up (Harmonics) 26
EN61000-3-3 Flicker and Fluctuations 31
Test Control Set-up (Flicker) 33
Meter View (Flicker) 35
Flicker Meter Page 35
Voltage Variation Page 36
Peak Inrush Current Measurement 38
Test Control Set-up (Peak Inrush Current) 40
Report View 41
Report Formats 42
Report Set-up 45
Compliance Measurements with the HA1600 47
Overview of Harmonics Measurements 47
Taking Harmonics Measurements 48
Taking Flicker and Fluctuation Measurements 50
HA-PC Link Plus Software 51
Software Installation 51
Operation of the HA-PC Link Plus Software 51
Installation of USB drivers 54
Maintenance & Calibration 55
Software Updates 56
Dokumenttyp:
Bedienungsanleitung
Seiten:
57
Größe:
1.28 Mbytes (1347096 Bytes)
Sprache:
english
Revision:
Issue 8
Dokument-ID:
48511-0400
Datum:
Qualität:
Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
03 November 2013
MD5:
df5913f6802787f4a7abf31d33b4fe57
Downloads:
683
Information
Introduction 2
Specification 3
Safety 5
EMC 7
Installation 8
Connections 9
Front Panel Connections 9
Rear Panel Connections 9
Initial Operation 10
Power Meter View 12
Power Meter Set-up 14
Waveform Graph View 15
Waveform Graph Set-up 16
Harmonics View 19
Harmonics Set-up 20
Display Format - Histogram 20
Display Format – Tables 23
Test Control View 25
Test Control Set-up (Harmonics) 26
EN61000-3-3 Flicker and Fluctuations 31
Test Control Set-up (Flicker) 33
Meter View (Flicker) 35
Flicker Meter Page 35
Voltage Variation Page 36
Peak Inrush Current Measurement 38
Test Control Set-up (Peak Inrush Current) 40
Report View 41
Report Formats 42
Report Set-up 45
Compliance Measurements with the HA1600 47
Harmonics Measurements 47
Taking Harmonics Measurements 48
Taking Flicker and Fluctuation Measurements 49
HA-PC Link Plus Software 50
Software Installation 50
Operation of the HA-PC Link Plus Software 50
Installation of USB drivers 53
Maintenance & Calibration 54
Software Updates 55
Kommentar hinzufügen
Nutzungsbedingungen
Diese Nutzungsbedingungen enthalten Regeln zum Posten von Kommentaren. Indem Sie einen Kommentar abgeben, erklären Sie, dass Sie diesen Regeln zustimmen:
- Obwohl der Administrator versucht, Kommentare zu moderieren, ist es unmöglich, dass jeder Kommentar zu einem bestimmten Zeitpunkt moderiert wurde.
- Sie erkennen an, dass alle Kommentare die Ansichten und Meinungen des ursprünglichen Autors und nicht die des Betreibers dieser Seite enthalten.
- Sie erklären sich damit einverstanden, keine Materialien zu veröffentlichen, die wissentlich falsch, obszön, hasserfüllt, bedrohend, belästigend oder invasiv sind.
- Der Administrator hat das Recht, jeden Kommentar ohne Angabe von Gründen zu bearbeiten, zu verschieben oder zu entfernen.
Die Nichteinhaltung dieser Regeln kann dazu führen, dass weitere Kommentare abgelehnt werden.
Diese Allgemeinen Nutzungsbedingungen können jederzeit und ohne vorherige Ankündigung geändert werden.
Kommentare