Sencore TC154 Röhren Testgerät
Hersteller:

Bild 1 von 1
Wenn du irgendwelche anderen Fotos oder Handbücher für ein
Sencore TC154 hast,
kannst du die Dateien hier hochladen .
Modell:
TC154
Datum:
1969
Kategorie:
Gruppe:
Beschreibung:
Tube Checker
Information
The new Sencore Mighty Mite VI represents a unique
breakthrough in tube testers.
The Mighty Mite VI is completely solid state using the FET
in a balanced bridge for
an instant on checker. This new outstanding feature means
that no time is wasted
waiting for the checker to warm up and stabilize before
accurate testing can begin.
The new Mighty Mite is ready as soon as it is turned on. A
full load cathode current
check, high sensitivity grid leakage check, and the famous
Sencore Stethoscopic
shorts test make this the ideal checker for service work and
the man on the go.
Check the features of the Mighty Mite below:
* Full load cathode current check to pick out the weak tubes
other checkers miss.
* 100 megohm grid leakage sensitivity to find the tough dog
tubes fast.
* Stethoscopic shorts test of 300K to pick out true shorts
in the tube.
* Burnout proof meter, even if a shorted tube is tested
backwards.
* FET balanced bridge circuitry for instant on action and
greater accuracy.
* All steel case for maximum protection and good looks for
the life of the checker.
Dokumenttyp:
Serviceanleitung
Seiten:
12
Größe:
365.43 Kbytes (374204 Bytes)
Sprache:
english
Revision:
Dokument-ID:
Datum:
14 Juli 1969
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
04 Mai 2014
MD5:
cbe3f4ed18534984e1b3ea24a450c045
Downloads:
841
Information
SAFETY
PRECAUTIONS ...
2
DESCRIPTION ...
... 3
SPECIFICATIONS ... ... ... 3
Tests the Mighty Mite will make ...
... ... 3
OPERATION ... 4
Acquainting yourself with the Mighty Mite
... ... 4
Operating the Mighty Mite
...
... 4
Additional Tests and Functions of the Mighty Mite
... ... 5
Setting up the Mighty Mite for new
tubes ...
... 6
Example of setting up the Mighty
Mite ...
... 7
MAINTENANCE ... 8
Disassembly Instructions ...
... 8
Emission
Calibration ...
... 8
Circuit description ...
... 9
Trouble
chart ... 10
Parts List
...
... 11
Service and
Warranty ...
... 12
FIGURES
Fig. 1 - 9QL Tube basing
...
... 7
Fig. 2 - Cal Module
Schematic ... 8
Fig. 3 - P. C. Board layout
...
... 9
Fig. 4 - Schematic diagram
...
... 11
Kommentar hinzufügen
Nutzungsbedingungen
Diese Nutzungsbedingungen enthalten Regeln zum Posten von Kommentaren. Indem Sie einen Kommentar abgeben, erklären Sie, dass Sie diesen Regeln zustimmen:
- Obwohl der Administrator versucht, Kommentare zu moderieren, ist es unmöglich, dass jeder Kommentar zu einem bestimmten Zeitpunkt moderiert wurde.
- Sie erkennen an, dass alle Kommentare die Ansichten und Meinungen des ursprünglichen Autors und nicht die des Betreibers dieser Seite enthalten.
- Sie erklären sich damit einverstanden, keine Materialien zu veröffentlichen, die wissentlich falsch, obszön, hasserfüllt, bedrohend, belästigend oder invasiv sind.
- Der Administrator hat das Recht, jeden Kommentar ohne Angabe von Gründen zu bearbeiten, zu verschieben oder zu entfernen.
Die Nichteinhaltung dieser Regeln kann dazu führen, dass weitere Kommentare abgelehnt werden.
Diese Allgemeinen Nutzungsbedingungen können jederzeit und ohne vorherige Ankündigung geändert werden.
Kommentare