Fluke 335D Test Set
Hersteller:
Bild 1 von 1
Wenn du irgendwelche anderen Fotos oder Handbücher für ein
Fluke 335D hast,
kannst du die Dateien hier hochladen .
Modell:
335D
Datum:
1972
Kategorie:
Gruppe:
Beschreibung:
Voltage Standard Differential Voltmeter Null Det
Information
The Model 335D Voltage Standard combines a dc Voltage Source
and a dc voltage measurement capability in one instrument.
Precision dc voltages up to 1100 volts, variable by way of
the front panel readout dials, are provided at the OUTPUT
terminals of the instrument. Measurement capabilities from
10 microvolts to 1000 volts are provided by a precision dc
differential voltmeter. This combination allows flexible use
of the instrument as a voltage standaj-4, a differential
voltmeter, or as a null detector.
1-3. Protection against possible equipment failures or
operator errors, which might otherwise damage expensive
instruments, is incorporated. The VOLTAGE TRIP and VERNIER
controls provide a msans of limiting the output voltage
within the range. Should the output voltage exceed a preset
limit, the OUTPUT terminals are deenergized. A current
limiting circuit limits the available current to a level
determined by the setting of the CURRENT LIMIT control.
Therefore, it is able to provide currents up to, but not
exceeding the level determined by the setting of the CURRENT
LIMIT control.
14. The inner chassis and circuitry are surrounded by an
isolation guard which is also isolated from the front panel
and the outside cover. When properly connected, the guard
bypasses any circulating ground currents which otherwise may
cause error. Remote sensing of the output voltage is also
used with the instrument to reduce errors caused by voltage
drop in external cables.
1-5. Most of the instrument circuitry is mounted on modular
Plug-In cards. An extender card is provided as an accessory
to aid in the maintenance and adjustment of the instrument.
Dokumenttyp:
Bedienungsanleitung
Seiten:
58
Größe:
2.55 Mbytes (2674117 Bytes)
Sprache:
english
Revision:
Dokument-ID:
Datum:
Qualität:
Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
2016 02 09
MD5:
16937316aa7593e2cecf40f06b9af6cc
Downloads:
1040
Information
1
2
3
TITLE PAGE
INTRODUCTION AND
SPECIFICATIONS ...
1-i
1-1.
introduction ...
... 1-1
1 -6.
Specifications ...
... 1-1
1-7.
Voltage
Standard ...
... 1-1
1-8.
Differential
Voltmeter ...
... 1-2
1-9.
Conventional Voltmeter ...
... 1-2
1-10.
General ...
... 14
OPERATING
INSTRUCTIONS ...
2-1
2-1. Introduction
...
2-1
2-4. Controls, Terminals, and
indicators ...
2-1
2-6. input
Power ...
2-1
2-8. Preliminary
Operation ...
2-1
2-9.
General ...
2-1
2-11. Trip
Setting ...
2-1
2-13. Current Limit
Setting ... 24
2-15. * VM AC Common Connections ... 24
2-17. Sense
Connections ...
. 24
2-20. Guard
Connection ... ... 2-5
2-24. Operation as a High Impedance Voltmeter ' 1
or Null
Detector ... ·.·"·.
... 2-7
2-26. Operation as a Differential Voltmeter ; . : .
... 2-7
2-28. Operation with a
Recorder ...
2-8
THEORY OF OPERATION ...
... 3-1
3-1 Introduction . . .
...
3-1
3-3 Voltage Standard
Function ...
3-1
3-40 Voltmeter
Function ...
3-7
4
MAINTENANCE ... 4-1
4-!
Introduction ... 4-1
4*3 Service
Information ... 4-1
4-6 General Maintenance
... 4-1
4-21 Performance
Tests ... '
. . 4-6
4-46
Calibration ... 4-13
4-66
Troubleshooting ... *
4-20