Beschreibung:
Informationen:
                                    The TR4172 spectrum Analyzer is a microprocessor-controlled,
intelligent instrument with a frequency range from 50 Hz to
1800 MHz. in addition to the spectrum analyzing function,
the integrated tracking Generator of TR4172 enables analysis
of frequency response of filters, amplifiers, and so on.

TR4172 is the first spectrum Analyzer with a capability for
measuring phase response and group delay of filters or
amplifiers at resolutions of down to 0.1 deg and 0.1 ns
respectively, up to a frequency of 1800 MHZ.

The integrated tracking generator, along with the analyzer’ร
intelligent control capability, permits correction of the
analyzer's frequency response itself allowing precision
level measurement.

A wide dynamic range is ensured by the low higher-harmonic
distortion level of 90 dB at and above 20 MHz, with respect
to a signal level of -40 dBm.

The display screen has a dynamic range of more than 95 dB
and permits direct observation of filter responses with
large attenuations.

The vertical resolution of the scale can be selected from
10, 5, 2, 1, and 0.1 dB per division, observation of a
ripple level of even 0.01 dB is possible with the maximum
resolution setting.

Use of the SAVE switch makes various measurements available,
with which up to eight sets of measurement condition data
are stored in the internal registers and recalled as needed.
Since the internal memory is backed up by a battery, its
contents remain intact even if the device is unplugged from
its supply outlet.

All front panel functions are remotely controllable with the
GPIB Interface (standard supply) for automatic measurement.
The CRT display presents all pertinent measurement data. The
signal response trace and measurement data on the screen can
be output to an X-Y plotter simply by connecting the
instrument*ร GPIB connector to the plotter'ร input with a
GPIB cable and operating the relevant front-panel switches,
without the need for running an output program on the GPIB
controller.

TR4172 also provides various convenient features to enhance
measurement flexibility and efficiency, such as multiple
marker, zoom, automatic centering, automatic enlargement,
auto-peak search, logarithmic scaling, and four page
memorized display.

1-2. FEATURES

(1)	Spectrum, amplitude, phase and group-delay measurement
capability at resolutions of down to 10 Hz, 0.1 dB/div., 0.2
deg/div., and 0.1 ns/div. respectively.

(2)	Wide dynamic range of 90 dB at “40 dBm input level
(above 20 MHz).

(3)	CRT screen with a large display dynamic range of more
than 95 dB permitting direct observation of large
attenuation responses.

(4)	Simultaneous four trace display allowing waveform
comparison.

(5)	Multiple marker.

(6)	Automatic correction of bandwidth switching error, step
Amplifier switching error, and frequency response error.

(7)	Scaling the horizontal graticule divisions in
logarithmic scale.

(8)	Output to an X-Y plotter supported without the need for
the external GPIB controller.

(9)	Remote operation of all front panel functions via the
external GPIB Interface facility (standard supply).

Reading capability for measurement data and labels on the
screen and writing capability for characters and data on the
screen.

Folgende Anleitungen sind hier verfügbar:

Dokumenttyp: Bedienungsanleitung Advantest-3972-Manual-Page-1-Picture
Seitenanzahl: 1092
Dateigröße: 11.29 Mbytes (11835089 Bytes)
Sprache: Englisch
Revision: first edition
Dokument-ID/Nummer: ED01 9509
Datum: 01 September 1982
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: 02b203762181a34cdffb85707f300145
Downloads: 479 seit dem 13 Januar 2013
Informationen:
Advantest-3972-Manual-Page-1-Picture


Dokumenttyp: Bedienungsanleitung Advantest-3973-Manual-Page-1-Picture
Seitenanzahl: 34
Dateigröße: 483.46 Kbytes (495066 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer:
Datum: 1986
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: 47bc365ef65d983e2b0158dc9dc263fa
Downloads: 791 seit dem 13 Januar 2013
Informationen:
INSTRUCTION MANUAL Vol I
Advantest-3973-Manual-Page-1-Picture


Dokumenttyp: Bedienungsanleitung Advantest-5736-Manual-Page-1-Picture
Seitenanzahl: 1195
Dateigröße: 22.57 Mbytes (23668881 Bytes)
Sprache: Englisch
Revision: First Printing
Dokument-ID/Nummer: ED01 9509
Datum: 1982
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: 8f19f6b9a4e8e59fb7ceb28489d97180
Downloads: 314 seit dem 22 April 2014
Informationen:
INSTRUCTION MANUAL Vol I
Advantest-5736-Manual-Page-1-Picture


Dokumenttyp: Bedienungsanleitung Advantest-7993-Manual-Page-1-Picture
Seitenanzahl: 294
Dateigröße: 7.94 Mbytes (8327713 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer:
Datum:
Qualität: Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
MD5: 66c6e447836ddf52c0d9b0b5f7295204
Downloads: 137 seit dem 17 August 2016
Informationen:
Advantest-7993-Manual-Page-1-Picture


Dokumenttyp: Serviceanleitung Advantest-7994-Manual-Page-1-Picture
Seitenanzahl: 186
Dateigröße: 6.22 Mbytes (6523010 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: EAOO 8704
Datum: 01 September 1982
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: 715194f423367f47f7c9fc7bdc09f1d8
Downloads: 153 seit dem 17 August 2016
Informationen:
INSTRUCTION MANUAL Vol I
Advantest-7994-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics