                                    Tektronix TDS 400 Digitizing Oscilloscopes are portable instruments suitable
for use in a variety of test and measurement applications and systems. Key
features include:
H Four input channels on the TDS 420 and TDS 460 (two input channels on
the TDS 410), each with a record length of 500 to 15,000 points and 8-bit
vertical resolution. (Option 1M extends the maximum record length to
60,000 points.)
H Simultaneous acquisition of waveforms in all channels at the maximum
digitizing rate of 100 Megasamples/second. All channels acquire at the
full analog bandwidth of 150 MHz (TDS 410 and TDS 420) or 350 MHz
(TDS 460) and all have the same features.
H Video triggering capabilities (with Option 5, Video Trigger).
H Full programmability and printer/plotter output.
H Advanced functions, such as continuously updated measurements.
H Specialized display modes, such as infinite and variable persistence.
H A unique graphical user Interface (GUI), an on-board help mode, and a
logical front-panel layout which combine to deliver a new standard in
usability.
H Advanced waveform math (with Option 2F, Advanced DSP Math). Com-
pute and display the integral of a waveform, the differential of a wave-
form, and the FFT (Fast Fourier Transform) of a waveform.

Folgende Anleitungen sind hier verfügbar:

Dokumenttyp: Serviceanleitung Tektronix-2501-Manual-Page-1-Picture
Seitenanzahl: 276
Dateigröße: 3.36 Mbytes (3522291 Bytes)
Sprache: Englisch
Revision: Revision May 1994
Dokument-ID/Nummer: 070–8036–02
Datum: 31 Mai 1994
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: 8668ecedf37f0b1b1e01412ba815708a
Downloads: 1389 seit dem 13 Juni 2011
Informationen:
Tektronix-2501-Manual-Page-1-Picture


Dokumenttyp: Serviceanleitung Tektronix-2540-Manual-Page-1-Picture
Seitenanzahl: 278
Dateigröße: 3.35 Mbytes (3509167 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: 070–8036–03
Datum: 1993
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: f73275f378990659b68440d6e89e9946
Downloads: 915 seit dem 18 Juni 2011
Informationen:
Tektronix-2540-Manual-Page-1-Picture


Dokumenttyp: Service- und Bedienungsanleitung Tektronix-4518-Manual-Page-1-Picture
Seitenanzahl: 278
Dateigröße: 3.34 Mbytes (3504171 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer: 070–8036–03
Datum: 1993
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: 521d85071a911429e3efa479aa040053
Downloads: 556 seit dem 28 April 2013
Informationen:
This manual is divided into sections, such as Specifications and Theory of Operation. Further, it is divided into subsections, such as Product Description and Removal and Installation Procedures.

Sections containing procedures also contain introductions to those procedures. Be sure to read these introductions, because they provide information needed to do the service correctly and efficiently. The following is a brief description of each manual section.

■	Specifications — contains a product description of the digitizing Oscilloscope and tables of the characteristics and descriptions that apply to it.

■	Operating Information — is this section. It includes a description of how this manual is structured, as well as general information and operating instructions at the level needed to safely power up and service this Oscilloscope. A statement of the service strategy that this manual supports, as well as instructions for shipment of the digitizing Oscilloscope, are found in this section.

■	Theory of Operation — contains circuit descriptions that support general service and fault isolation.

■	Performance Verification — contains a collection of procedures for confirming that this digitizing Oscilloscope functions properly and meets warranted limits.

■	Adjustment Procedures — contains a collection of procedures for adjusting this digitizing Oscilloscope to meet warranted limits.

■	Maintenance — contains information and procedures for doing preventive and corrective maintenance of the digitizing Oscilloscope. Instructions for cleaning, for module removal and installation, and for fault isolation to a module are found here.

■	Options — contains information on servicing any of the factory-installed options that may be present in your Oscilloscope.

■	Electrical Parts List — contains a statement referring you to the Mechanical Parts List, where both electrical and mechanical modules are listed. See below.

■	Diagrams — contains a block diagram and an interconnection diagram useful for isolating failed modules.

■	Mechanical Parts List — includes a table of all replaceable modules, their descriptions, and their Tektronix part numbers.
Tektronix-4518-Manual-Page-1-Picture


Dokumenttyp: Bedienungsanleitung Tektronix-4519-Manual-Page-1-Picture
Seitenanzahl: 378
Dateigröße: 2.00 Mbytes (2102273 Bytes)
Sprache: Englisch
Revision: Seventh edition
Dokument-ID/Nummer: 070-8709-06
Datum: November 1994
Qualität: Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
MD5: 95d81baea023aa2e8c63a91e8335a437
Downloads: 2335 seit dem 28 April 2013
Informationen:
This manual is divided into sections, such as Specifications and Theory of Operation. Further, it is divided into subsections, such as Product Description and Removal and Installation Procedures.

Sections containing procedures also contain introductions to those procedures. Be sure to read these introductions, because they provide information needed to do the service correctly and efficiently. The following is a brief description of each manual section.

■	Specifications — contains a product description of the digitizing Oscilloscope and tables of the characteristics and descriptions that apply to it.

■	Operating Information — is this section. It includes a description of how this manual is structured, as well as general information and operating instructions at the level needed to safely power up and service this Oscilloscope. A statement of the service strategy that this manual supports, as well as instructions for shipment of the digitizing Oscilloscope, are found in this section.

■	Theory of Operation — contains circuit descriptions that support general service and fault isolation.

■	Performance Verification — contains a collection of procedures for confirming that this digitizing Oscilloscope functions properly and meets warranted limits.

■	Adjustment Procedures — contains a collection of procedures for adjusting this digitizing Oscilloscope to meet warranted limits.

■	Maintenance — contains information and procedures for doing preventive and corrective maintenance of the digitizing Oscilloscope. Instructions for cleaning, for module removal and installation, and for fault isolation to a module are found here.

■	Options — contains information on servicing any of the factory-installed options that may be present in your Oscilloscope.

■	Electrical Parts List — contains a statement referring you to the Mechanical Parts List, where both electrical and mechanical modules are listed. See below.

■	Diagrams — contains a block diagram and an interconnection diagram useful for isolating failed modules.