Rigol Technologies Inc. VS5000 Oszilloskop
Hersteller:
Bild 1 von 1
Wenn du irgendwelche anderen Fotos oder Handbücher für ein
Rigol Technologies Inc. VS5000 hast,
kannst du die Dateien hier hochladen .
Modell:
VS5000
Datum:
2008
Kategorie:
Gruppe:
Beschreibung:
Digital Oscilloscope
Information
RIGOL VS5000 Series Digital Oscilloscopes offer good
waveform view and
measurements in a compact, lightweight package. VS5000
series are ideal for
production test, field service, research and design and all
of the applications
involving analog circuits test and troubleshooting, as well
as education and training.
Product features:
Dual Channel, Bandwidth:
200MHz (VS5202, VS5202D)
100MHz (VS5102, VS5102D)
60MHz (VS5062, VS5062D)
40MHz (VS5042, VS5042D)
25MHz (VS5022, VS5022D)
A true Mixed Signal Oscilloscope with 16 channels Logic
Analyzer (for some
models)
400 MSa/s maximum real-time sample rate and 25 GSa/s maximum
equivalent
sample rate
Memory depth: 1M points (Single Channel), 512k points (Dual
Channels), 512k
points (Logic Analyzer)
Adjustable waveform intensity, more effective waveform view
One-touch automatic setup for ease of use (AUTO)
20 Automatic measurements
Automatic cursor tracking measurements
Waveform recorder, record and replay dynamic waveforms
User selectable fast offset calibration
Built-in FFT function, Frequency Counter
Digital filters, includes LPF, HPF, BPF, BRF
Add, Subtract and Multiply Mathematic Functions
Advanced trigger types include: Edge, Video, Pulse width,
Slope, Alternative,
Pattern and Duration
Adjustable trigger sensitivity
Dokumenttyp:
Bedienungsanleitung
Seiten:
138
Größe:
3.02 Mbytes (3161929 Bytes)
Sprache:
english
Revision:
Dokument-ID:
VS5000-080331
Datum:
2008 03 01
Qualität:
Elektronisches Dokument, kein Scan, sehr gut lesbar.
Upload Datum:
2017 05 13
MD5:
54bd66b12bff7e1e839f1a848ca32e8f
Downloads:
909
Information
Safety Notices
...
II
VS5000 Oscilloscopes at a Glance
...
V
Chapter 1 Quick Start
...
1-1
The Front Panel and User’s
Interface ...
1-2
To Inspect the Instrument
...
1-5
To Perform a Functional Check
...
1-6
To Compensate Probes
...
1-8
To Use Digital Leads (for VS5***D only)
... 1-9
To Display a Signal Automatically
... 1-11
To Understand the Vertical Window
... 1-12
To Understand the Horizontal System
... 1-14
To Trigger the Oscilloscope
... 1-16
Chapter 2 Operating Your Oscilloscope
... 2-1
To
Set the Vertical system
...
2-2
To
Set the Horizontal
System ... 2-23
To
Set the Trigger System
... 2-29
To
Set the Sampling System
... 2-43
To
Save/Load and Print
Setup ... 2-47
To
Set the Measurement Function
... 2-53
To
Set the Utility Function
... 2-66
To
Use Run Control
Buttons ... 2-72
Chapter 3 Application Examples
... 3-1
Example
1: Taking Simple Measurements
... 3-1
Example
2: View a Signal Delay Caused by a Circuit
... 3-3
Example
3: Capture a Single-Shot Signal
... 3-4
Example
4: To Reduce the Random Noise on a Signal
... 3-5
Example
5: Making Cursor
Measurements ... 3-7
Example
6: The Application of the X-Y Operation
... 3-9
Example
7: Triggering on a Video
Signal ... 3-11
Example
8: FFT Cursor Measurement
... 3-13
Example
9: Pass/Fail
Test ... 3-14
Example
10: Triggering on a Digital Signal
... 3-
Chapter 4 Prompt Messages & Troubleshooting
... 4-1
Prompt Messages
...
4-1
Troubleshooting
...
4-4
Chapter 5 Specifications
...
5-1
Chapter 6 Appendix
...
6-1
Appendix
A: Accessories
...
6-1
Appendix
B:
Warranty ...
6-1
Appendix
C:
Maintenance ...
6-2
Appendix
D: Contact RIGOL
...
6-3
Index ...