- Bedienungsanleitung mit Schaltplan
- Reparatur und Bedienungsanleitung
- Reparatur und Bedienungsanleitung
Fluke - 8050A - Digital Multimeter
Hersteller:
Gerät:
8050A
Datum:
1979
Kategorie:
Gruppe:
Untergruppe:
Informationen
1-2. Your John Fluke Model 8050A is a portable bench-
type Digital multimeter (DMM) with a 4-1 /2 digit liquid
crystal display (LCD). The 8050A has all the following
industry-standard features:
» Voltage measurements from 10 μ to 1000V dcand 10 mV to
750V true-rms ac.
• Current measurements from 10 nA to 2A dc and 10 μΑ to 2A
true-rms ac.
® Resistance measurements from 10 mH to 20ΜΏ.
The 8050A also has several special measurement features.
These special features include the following:
• Conductance measurements up to 100,000 Mil.
• Voltage measurements in decibels, that can be referenced
to 1 of 16 user selected reference impedances.
® Resistance ranges that supply enough voltage to turn on a
PN junction to allow diodes and transistors to be tested.
• The ability to store any input signal as an offset or
relative reference value.
• Automatic polarity indication and overrange indication.
• Protection from overloads and protection from transients
of up to 6 kV, 10 microseconds.
• Dual-slope integration a/d conversion to ensure noise-free
measurements.
• Long term calibration stability (1 year).
1-3. The 8050A is warranted for a period of one year upon
shipment of the instrument to the original purchaser.
Conditions of the warranty are given at the front of this
manual. The 8050A is typically powered from ac line voltages
but may be powered by the optional rechargeable battery.
3 Handbücher
Bedienungsanleitung mit Schaltplan
Dokumenttyp:
Bedienungsanleitung mit Schaltplan
Seitenanzahl:
97
Größe:
2,9 MB
Sprache:
englisch
Revision:
2 7/84
Dokument-ID:
530907
Datum:
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
19. Februar 2009
MD5:
8c0a3ade-3a51-72d5-2d90-ef6687562db8
Downloads:
3692
Downloads letzter Monat:
3
Herunterladen
fluke--8050a--user-schematics--ID1437.pdf
Reparatur und Bedienungsanleitung
Dokumenttyp:
Reparatur und Bedienungsanleitung
Seitenanzahl:
104
Größe:
8,5 MB
Sprache:
englisch
Revision:
2
Dokument-ID:
530907
Datum:
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
27. Januar 2016
MD5:
9046d898-8f51-2b66-5539-42430b1b1d33
Informationen
1 INTRODUCTION AND SPECIFICATIONS 1-1
1-1. INTRODUCTION 1-1
1-4. OPTIONS AND Accessories 1-1
1-5. SPECIFICATIONS
...
1-1
2 OPERATION
...
2-1
2-1. INTRODUCTION
...
2-1
2-3. SETTING UP YOUR INSTRUMENT ... 2-1
2-4. Unpacking
...
2-1
2-8. AC Line Voltage Requirements 2-1
2-10. Fuse Replacement 2-1
2-13. FRONT PANEL FEATURES 2-2
2-15. Display 2-2
2-18. SIGNAL INPUT LIMITS 2-2
2-20. OPERATING TECHNIQUES 2-3
2-22. AC/DC Voltage (V) 2-3
2-24. AC/ DC Current (mA) 2-3
2-26. Resistance (Ω) 2-7
2-28. Conductance (S = 1Ω) 2-7
2-30. Diode Test 2-7
2-32. Relative (RELATIVE) 2-7
2-36. Decibel (dB) 2-11
2-38. INITIAL CHECKOUT PROCEDURE ... 2-12
2-41. APPLICATIONS 2-12
2-43. DC Voltage Measurement 2-12
2-51. Current Measurement 2-13
2-56. Resistance Measurement 2-13
2-62. Conductance Measurement 2-14
2-80. Relative Measurement 2-16
2-84. AC Voltage and Current
Measurement... 2-16
3 THEORY OF
OPERATION...
3-1
3-1. INTRODUCTION
...
3-1
3-3. FUNCTIONAL DESCRIPTION 3-1
TITLE PAGE
3-7. A/D Converter 3-1
3-18. Microcomputer
...3-2
3-20. Signal Conditioning
...3-6
3-31. True-RMS Converter 3-8
3-38. Touch-Hold Circuit
...3-8
3-40. Voltage Protection
...3-8
3-43. Current Protection
...3-8
4 MAINTENANCE
...
4-1
4-1. INTRODUCTION
...
4-1
4-4. SERVICE INFORMATION
...
4-1
4-7. GENERAL INFORMATION
...
4-1
4-9. Interior
Access...
4-1
4-24. dB Reference Impedance Power-Up
Setting... 4-4
4-26. Cleaning
...
4-5
4-28. PERFORMANCE TESTS
...
4-5
4-30. Initial Procedures
...
4-5
4-32. Display
Test...
4-5
4-34. Linear Voltage Test
...
4-6
4-36. dB Voltage
Test...
4-6
4-38. Current
Test...
4-7
4-40. Resistance and Conductance
Tests... 4-7
4-42. CALIBRATION ADJUSTMENTS
... 4-8
4-44. DC Calibration
...
4-8
4-46. AC Calibration
...
4-8
4-48. Jumper
Selection...
4-8
4-57. TROUBLESHOOTING
...
4-12
5 LIST OF REPLACEABLE PARTS
...
5-1
TABLE OF CONTENTS
...
5-1
5-1. INTRODUCTION
...
5-2
5-3. PARTS ORDERING INFORMATION
... 5-2
6 OPTIONS AND Accessories 6-1
TABLE OF CONTENTS
...
6-1
INTRODUCTION
...
6-2 Accessories 600-1
OPTIONS
...
601-1
7 SCHEMATIC DIAGRAMS
...
7-1
TABLE OF CONTENTS
...
7-1
APPENDIX A
...
A-1
Downloads:
1130
Downloads letzter Monat:
10
Herunterladen
fluke--8050a--service-user--ID7619.pdf
Reparatur und Bedienungsanleitung
Dokumenttyp:
Reparatur und Bedienungsanleitung
Seitenanzahl:
106
Größe:
5,1 MB
Sprache:
englisch
Revision:
2
Dokument-ID:
530907
Datum:
Qualität:
Gescanntes Dokument, alles ist lesbar.
Upload Datum:
13. Februar 2016
MD5:
645b1f5f-0f6c-33dd-dc5f-e37e20c5466f
Informationen
1
2
TITLE PAGE
INTRODUCTION AND SPECIFICATIONS
... 1-1
l-l. INTRODUCTION .
I-4. OPTIONS AND ACCESi
I-5. SPECIFICATIONS
...
1-1
SORIES...
1-1
...
1-1
OPERATION
...
2-1
2-1. INTRODUCTION
...
2-1
2-3. SETTING UP YOUR INSTRUMENT
... 2-1
2-4. Unpacking
...
2-1
2-8. AC Line Voltage Requirements
...
2-1
2-10. Fuse
Replacement...
2-1
2-13. FRONT PANEL
FEATURES...
2-2
2-15. Display
...
2-2
2-18. SIGNAL INPUT LIMITS
...
2-2
2-20. OPERATING
TECHNIQUES...
2-3
2-22. AC/DC Voltage (V)
...
2-3
2-24. AC/DC Current (mA)
...
2-3
2-26. Resistance (Ω)
...
2-7
2-28. Conductance (S =
IΩ)...
2-7
2-30. Diode Test
...
2-7
2-32. Relative (RELATIVE)
...
2-7
2-36. Decibel
(dB)...
2-11
2-38. INITIAL CHECKOUT PROCEDURE
... 2-12
2-41. APPLICATIONS
...
2-12
2-43. DC Voltage Measurement
...,...
2-12
2-51. Current Measurement
...
2-13
2-56. Resistance Measurement
...
2-13
2-62. Conductance Measurement
...
2-14
2-80. Relative Measurement
...
2-16
2-84. AC Voltage and Current
Measurement... 2-16
THEORY OF
OPERATION...
3-1
3-1. INTRODUCTION
...
3-1
3-3. FUNCTIONAL DESCRIPTION
... 3-1
3-5. CIRCUIT
DESCRIPTION...
3-1
TITLE PAGE
3-7. A/D Converter 3-1
3-18. Microcomputer
...3-2
3-20. Signal Conditioning
...3-6
3-31. True-RMS Converter 3-8
3-38. Touch-Hold Circuit
...3-8
3-40, Voltage Protection
...3-8
3-43. Current Protection
...3-8
4 MAINTENANCE
...
4-1
4-1. INTRODUCTION
...
4-1
4-4. SERVICE INFORMATION
...
4-1
4-7. GENERAL INFORMATION
...
4-1
4-9. Interior
Access...
4-1
4-24. dB Reference Impedance Power-Up
Setting... 4-4
4-26. Cleaning
...
4-5
4-28. PERFORMANCE TESTS
...
4-5
4-30. Initial Procedures
...
4-5
4-32. Display
Test...
4-5
4-34. Linear Voltage Test
...*...
4-6
4-36. dB Voltage
Test...
4-6
4-38. Current
Test...
4-7
4-40. Resistance and Conductance Tests
... 4-7
4-42. CALIBRATION ADJUSTMENTS
... 4-8
4-44. DC Calibration ...
... 4-8
4-46. AC Calibration ...
... 4-8
4-48. Jumper
Selection...
4-8
4-57. TROUBLESHOOTING
...
4-12
5 LIST OF REPLACEABLE PARTS
...
5-1
TABLE OF CONTENTS
...
5-1
5-1. INTRODUCTION
...
5-2
5-3. PARTS ORDERING INFORMATION
... 5-2
6 OPTIONS AND Accessories 6-1
TABLE OF CONTENTS
...
6-1
INTRODUCTION
...
6-2 Accessories 600-1
OPTIONS
...
601-1
7 SCHEMATIC DIAGRAMS
...
7-1
TABLE OF CONTENTS
...
7-1
APPENDIX A
...
A-1
Downloads:
2177
Downloads letzter Monat:
13
Herunterladen
fluke--8050a--service-user--ID7727.pdf