Информация по оборудованию:

Fluke Y8100 Зонд
Производитель:
Fluke
Модель: Y8100
Дата: 1994
Категория: Измерительная техника
Группа: Зонд
Описание: DC/AC Clamp-on Current Probe
Информация:
                                    The Fluke Y8100 DC/AC Current Probe is a clamp-on probe that
is used with a voltmeter, multimeter, or oscilloscope to
read dc, ac, or composite (ac on dc) current measurements.
The jaws on the Y8100 are designed to clamp around
conductors up to % inch in diameter. The pistol shape allows
safe, easy, one-hand operation when making current measurements.

APPLICATIONS

The Y8100 can be used to measure any of the following:

. Ground currents ac and dc.

Power supply ripple.

. Current distribution in multiple systems.

Current balance in two wires ac and dc.

. Current in audio distribution systems (using 440 to 1000
Hz signals).

Starting currents without introducing impedance (imparts
negligible inductance in the mH range).

Transformer currents

. Battery currents

. Current distribution and perform ripple current tests in
plating operations.

. Current transients (dc to l kHz) when used with an
oscilloscope.

Эти руководства доступны для вышеуказанного оборудования:

Руководство Тип: Обслуживание и Руководство пользователя Fluke-10175-Manual-Page-1-Picture
Страницы: 36
Размер: 2.50 Mbytes (2626583 Bytes)
Язык: английский
Редакция: 2
Manual-ID/Number: 534271
Дата: 01 Ноябрь 1994
Качество: Отсканированы документу, все читается.
Дата публикации:
MD5: 135077944a41738870bdd340014d1fc5
Скачиваний: 46 начиная с 28 Январь 2018
Информация:
Instruction Manual

l-l. DESCRIPTION
......................................................................l-l

I-5. FEATURES
............................................................................I-2

1-7.	UNPACKING
........................................................................I-4

2	OPERATING INSTRUCTIONS
....................................................2-1

2-1.
INTRODUCTION..................................................................2-1

2-3. SAFETY HINTS
....................................................................2-1

2-4. MEASUREMENT NOTES
..................................................2-I

2-5. MEASURING AC CURRENT
..........................................2-3

2-6. MEASURING DC CURRENT
..........................................2-3

2-7.	MEASURING COMPOSITE (AC-ON-DC) CURRENT	2-4

3	THEORY OF OPERATION
............................................................3-1

3-1.	INTRODUCTION
..................................................................3-I

4	MAINTENANCE
................................................................................4-1

4-1.	INTRODUCTION
..................................................................4-1

4-3. BATTERY INSTALLATION
..............................................4-I

4-6. CALIBRATION
....................................................................4-2

4-12. DEMAGNETIZING CIRCUIT CHECK PROCEDURE	4-6

4-13.	TROUBLESHOOTING
........................................................4-6

5	LIST OF REPLACEABLE PARTS
................................................5-1

5-1.
INTRODUCTION..................................................................5-1

5-3. HOW TO OBTAIN
PARTS....................................................5-1

5-7. SERVICE
CENTERS............................................................5-1

6	SCHEMATIC DIAGRAMS
..............................................................6-1
Fluke-10175-Manual-Page-1-Picture