IFR FM/AM-1600S Communications Service Monitor
Fabricante:
Modelo:
FM/AM-1600S
Data:
1991
Categoria:
Grupo:
Descrição:
COMMUNICATIONS SERVICE MONITOR

Informação

The FM/AM-1600S is a microprocessor controlled, digitally synthesized communication service monitor which combines the operations of many different test instruments into a single, compact unit. Functions the FM/AM-1600S is capable of performing include: RF Generator Duplex Spectrum Analyzer DMM Distortion Meter Audio Frequency Meter RF Power Meter Signal Strength Meter Phase Meter Tracking Generator Digital Radio Paging Encode and Decode Receiver AF Generator Oscilloscope Deviation (Peak) Meter SINAD Meter Frequency Error Meter Modulation Meter Bit Error Rate Meter Deviation (RMS) Meter Cable Fault Detector Analog Radio Paging Encode and Decode The FM/AM-1600S utilizes an alphanumeric keypad, dedicated function keys, multitask Soft Function Keys and a high-resolution color CRT to display, enter and edit functions and data. Testing with this instrument can be done remotely or manually. The FM/AM-1600S can perform tests from pre-programmed setups or formats determined at the time of the test. Microprocessor controlled memory allows storage and recall of parameters for each of the testing modes as well as storage and recall of Oscilloscope and Spectrum Analyzer traces for signal comparison. The FM/AM-1600S is capable of generating modulated or unmodulated carrier signals from 250 kHz to 999.9999 MHz (in 100 Hz steps). The output level is variable from -137 dBm to 0 dBm. Modulation types include AM, FM and PM. Modulation can also be applied from an external source. The RF Generator also functions as a tracking generator for swept measurements or as an offset generator in Duplex Mode. Metering functions available for this operation mode include SINAD, DMM, Distortion and Audio Frequency Level meters. The Oscilloscope and Spectrum Analyzer are also available for use on the RF Generator Operation Screen. 1-3 Receiver The FM/AM-1600S is capable of receiving modulated and unmodulated signals from 250 kHz to 999.9999 MHz (in 100 Hz steps). The FM/AM-1600S receives AM, FM, PM, and SSB modulated signals. Metering functions in the FM/AM-1600S available with the Receiver include RF Power, Modulation, Deviation, Distortion, Frequency Error, AF Frequency, Signal Strength and SINAD meters and counters. The Oscilloscope and Spectrum Analyzer are also available for use on the Receiver Operation Screen. The FM/AM-1600S Receiver is capable of executing user defined frequency scan operations as well as single frequency operations. The Receiver accesses "off the air" signals through the Antenna IN Connector or higher powered signals are accessed through the T/R Connector.

mostrar mais

Manual do Usuário
Tipo de manual:
Manual do Usuário
Páginas:
428
Tamanho:
12.60 Mbytes (13216305 Bytes)
Idioma:
english
Revisão:
1.10
ID de manual:
1002-8600-000
Data:
Qualidade:
Scaned documento, todas legível.
Data de upload:
2015 05 23
MD5:
154a1375e4ea7f9ae2d5989f9cd0d3ac
Downloads:
997

Informação

This manual contains instructions for operating the FM/AM-1600S Communications Service Monitor. The instruction level is relatively basic and presupposes no previous experience on the part of the operator with a communication service monitor of this type. A basic understanding of communication electronics and practical troubleshooting methods is helpful. It is strongly recommended that the operator be thoroughly familiar this manual before attempting to operate the unit. ORGANIZATION The FM/AM-1600S Operation Manual is composed of the following sections: SECTION 1 - INTRODUCTION Provides an introduction to the unit and a brief overview of unit functions. Specifications are also included in this section. SECTION 2 - INSTALLATION Provides a step-by-step procedure for placing the FM/AM-1600S into operation. SECTION 3 - DESCRIPTION OF CONTROLS, CONNECTORS AND INDICATORS Identifies and functionally describes all FM/AM-1600S controls, connectors and indicators. Additionally, all CRT Operation Screens and Menus are identified and available parameters listed and explained. NOTE: As an operating aid, Figures 3-1 and 3-2, which locate and identify all FM/AM-1600S controls, connectors and indicators, are located on a fold-out page. By extending the fold-out page, the operator can reference any front or rear panel control while simultaneously performing any operating procedure contained elsewhere in the manual. SECTION 4 - OPERATION Contains instructions for operating the FM/AM-1600S Mode Operating Screens and Menus, in addition, this section contains a selection of basic operating procedures pertaining to ail major functions of the set. SECTION 5 - PERFORMANCE EVALUATION identifies and explains procedures the operator can use to insure the FM/AM-1600S is performing properly. SECTION 6 - REMOTE OPERATION Contains step-by-step procedures for configuring and operating the FM/AM-1600S remotely. Lists unit specific commands for remote operations as well as commands mandated by IEEE 488.2 1987.

mostrar mais

Manual do Usuário
Tipo de manual:
Manual do Usuário
Páginas:
478
Tamanho:
14.44 Mbytes (15143113 Bytes)
Idioma:
english
Revisão:
2
ID de manual:
1002-8600-000
Data:
Qualidade:
Scaned documento, todas legível.
Data de upload:
2014 01 20
MD5:
9dfc3c965ee43df58766d68fab3f9383
Downloads:
1823

Informação

This manual contains instructions for operating the FM/AM-1600S Communications Service Monitor. The instruction level is relatively basic and presupposes no previous experience on the part of the operator with a communication service monitor of this type. A basic understanding of communication electronics and practical troubleshooting methods is helpful. It is strongly recommended that the operator be thoroughly familiar this manual before attempting to operate the unit. ORGANIZATION The FM/AM-1600S Operation Manual is composed of the following sections: SECTION 1 - INTRODUCTION Provides an introduction to the unit and a brief overview of unit functions. Specifications are also included in this section. SECTION 2 - INSTALLATION Provides a step-by-step procedure for placing the FM/AM-1600S into operation. SECTION 3 - DESCRIPTION OF CONTROLS, CONNECTORS AND INDICATORS Identifies and functionally describes all FM/AM-1600S controls, connectors and indicators. Additionally, all CRT Operation Screens and Menus are identified and available parameters listed and explained. NOTE: As an operating aid, Figures 3-1 and 3-2, which locate and identify all FM/AM-1600S controls, connectors and indicators, are located on a fold-out page. By extending the fold-out page, the operator can reference any front or rear panel control while simultaneously performing any operating procedure contained elsewhere in the manual. SECTION 4 - OPERATION Provides instructions for operating the FM/AM-1600S Mode Operating Screens and Menus. In addition, this section contains a selection of basic operating procedures pertaining to all major functions of the Test Set. SECTION 5 - PERFORMANCE EVALUATION Identifies and explains procedures the operator can use to insure the FM/AM-1600S is performing properly. SECTION 6 - REMOTE OPERATION Provides procedures for configuring and operating the FM/AM-1600S remotely. Lists unit specific commands for remote operations as well as commands mandated by IEEE 488.2 1987.

mostrar mais