Rigol Technologies Inc. VS5000 Oscyloskop
Producent:
Model:
VS5000
Data:
2008
Kategoria:
Grupa:
Opis:
Digital Oscilloscope

Informacja

RIGOL VS5000 Series Digital Oscilloscopes offer good waveform view and measurements in a compact, lightweight package. VS5000 series are ideal for production test, field service, research and design and all of the applications involving analog circuits test and troubleshooting, as well as education and training. Product features: Dual Channel, Bandwidth: 200MHz (VS5202, VS5202D) 100MHz (VS5102, VS5102D) 60MHz (VS5062, VS5062D) 40MHz (VS5042, VS5042D) 25MHz (VS5022, VS5022D) A true Mixed Signal Oscilloscope with 16 channels Logic Analyzer (for some models) 400 MSa/s maximum real-time sample rate and 25 GSa/s maximum equivalent sample rate Memory depth: 1M points (Single Channel), 512k points (Dual Channels), 512k points (Logic Analyzer) Adjustable waveform intensity, more effective waveform view One-touch automatic setup for ease of use (AUTO) 20 Automatic measurements Automatic cursor tracking measurements Waveform recorder, record and replay dynamic waveforms User selectable fast offset calibration Built-in FFT function, Frequency Counter Digital filters, includes LPF, HPF, BPF, BRF Add, Subtract and Multiply Mathematic Functions Advanced trigger types include: Edge, Video, Pulse width, Slope, Alternative, Pattern and Duration Adjustable trigger sensitivity

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
138
Rozmiar:
3.02 Mbytes (3161929 Bytes)
Język:
english
Rewizja:
Ręczny ID:
VS5000-080331
Data:
2008 03 01
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2017 05 13
MD5:
54bd66b12bff7e1e839f1a848ca32e8f
Pobrane:
911

Informacja

Safety Notices ... II VS5000 Oscilloscopes at a Glance ... V Chapter 1 Quick Start ... 1-1 The Front Panel and User’s Interface ... 1-2 To Inspect the Instrument ... 1-5 To Perform a Functional Check ... 1-6 To Compensate Probes ... 1-8 To Use Digital Leads (for VS5***D only) ... 1-9 To Display a Signal Automatically ... 1-11 To Understand the Vertical Window ... 1-12 To Understand the Horizontal System ... 1-14 To Trigger the Oscilloscope ... 1-16 Chapter 2 Operating Your Oscilloscope ... 2-1 To Set the Vertical system ... 2-2 To Set the Horizontal System ... 2-23 To Set the Trigger System ... 2-29 To Set the Sampling System ... 2-43 To Save/Load and Print Setup ... 2-47 To Set the Measurement Function ... 2-53 To Set the Utility Function ... 2-66 To Use Run Control Buttons ... 2-72 Chapter 3 Application Examples ... 3-1 Example 1: Taking Simple Measurements ... 3-1 Example 2: View a Signal Delay Caused by a Circuit ... 3-3 Example 3: Capture a Single-Shot Signal ... 3-4 Example 4: To Reduce the Random Noise on a Signal ... 3-5 Example 5: Making Cursor Measurements ... 3-7 Example 6: The Application of the X-Y Operation ... 3-9 Example 7: Triggering on a Video Signal ... 3-11 Example 8: FFT Cursor Measurement ... 3-13 Example 9: Pass/Fail Test ... 3-14 Example 10: Triggering on a Digital Signal ... 3- Chapter 4 Prompt Messages & Troubleshooting ... 4-1 Prompt Messages ... 4-1 Troubleshooting ... 4-4 Chapter 5 Specifications ... 5-1 Chapter 6 Appendix ... 6-1 Appendix A: Accessories ... 6-1 Appendix B: Warranty ... 6-1 Appendix C: Maintenance ... 6-2 Appendix D: Contact RIGOL ... 6-3 Index ...

pokaż więcej