BK Precision 9130 Zasilanie
Producent:
Brak zdjęcia!
Może możesz przesłać zdjęcie za
BK Precision 9130 ?
Jeśli masz jakieś inne podręczniki dla
BK Precision 9130, możesz przesłać pliki tutaj .
Model:
9130
Data:
2007
Kategoria:
Grupa:
Opis:
Triple Output Programmable DC Power Supply
Informacja
The 9130 is a fully programmable triple Output DC Power
Supply delivering 0-30V/0-3A on 2 outputs and 0-5V/0-3A on 1
output. Each output is fully floating and outputs can be
adjusted independently or connected in series or parallel to
produce higher voltages or currents. The front panel keys
and the control knob provide a convenient means to adjust
the voltage and current of a selected output; enable or
disable parallel or series tracking mode; store and recall
operating states or enable/disable individual outputs. The
9130 is ideally suited for applications in Electronic Test,
Production and Service, where multiple independent DC
supplies are required and bench space is at a premium.
Key Features
• 3 independent, fully programmable and electrically
isolated outputs
• Series or parallel operation
• Display Voltage and Current for of all 3 channels
simultaneously
• Over Current (OCP) and Over Temperature (OHT) protection
• Very compact foot print ( 2U x 1/2)
• Bright and easy to read display (VFD technology)
• High resolution, accuracy and stability
• Output on/off control
• Low ripple and low noise
• SCPI compatible command set, communicate via USB or RS232 port
• Application Software for front panel emulation and simple
test sequence generation
• 50 memory locations for instrument state storage & recall
• Convenient data entry via knob or numerical key pad
• Rack mount kit available
3
Typ ręczny:
Instrukcja obsługi
Strony:
48
Rozmiar:
1.73 Mbytes (1814753 Bytes)
Język:
english
Rewizja:
1.01
Ręczny ID:
Data:
2007 01 01
Jakość:
Skanowany dokument, wszystko czytelne.
Data przesłania:
2017 01 25
MD5:
1015682241a3a8b077de42c75b1bbdc5
Pobrane:
405
Informacja
1.
INTRODUCTION ... 3
2. QUICK
START ... 4
2.1 Front & Rear
Panel ... 4
2.2 Preliminary
Checkout ... 5
1. Check the list of supplied
items ... 5
2. Connect the power cord and turn on the power
supply ... 6
3. System
Checkout ... 6
4. Output
Verification ... 7
5. If the Power supply Does Not Turn
On ... 8
6. To Adjust the Carrying
Handle ... 8
7. To Rack Mount the
Instrument ... 9
3.
SPECIFICATIONS ...
10
3.1
Specifications ... 10
3.2 Supplemental
Characteristics ... 11
4. FRONT-PANEL
OPERATION ...
12
4.1 Front-panel Operation
Overview ... 12
4.2 Panel
Description ... 13
4.3 VFD Description and Wiring
Diagram ... 13
4.4 Menu
Descriptions ... 13
4.5 Panel
Operation ... 15
4.6 Menu
Function ... 17
□ Power
Config ... 17
□ System
Set ... 18
□ Power
Information ... 20
5. REMOTE
OPERATION ... 22
5.1 Communication
cable ... 22
5.2 Communication between Power supply and
PC ... 23
5.3 SCPI Command
Overview ... 24
5.3.1 Common IEEE488.2
commands ... 24
5.3.2 Essential SCPI
Commands ... 24
5.3.3 Nonstandard SCPI
Commands ... 25
5.4 SCPI Command
Description ... 26
5.4.1 SCPI Condition
Register ... 26
5.4.2 SCPI Command
Description ... 28
6. PV9130 Software
GUIDE ... 38
6.1
Introduction ...
38
6.2
Installation ... 38
6.3 PV9130
basics ... 38
6.3.1 Save and
Open ... 39
6.3.2 Chart
Description ... 40
6.3.3 Status
bar ... 40
6.4
Operation ... 41
6.4.1 Configure the
system ... 41
6.4.2 Setting Voltage and
Current ... 41
6.5 Test sequence
generation ... 42
6.5.1
Quickset ... 42
6.5.2
Program ... 42
6.5.2
Go/NG ... 43