Telecommunications Techniques Corporation DS3 Interfejs
Producent:
Model:
DS3
Data:
1993
Kategoria:
Grupa:
Opis:
Interface Module

Informacja

The DS3 Interface Module gives the FIREBERD 6000 and FIREBERD4000Communications Analyzers the ability to test circuits and equipment operating at the DS3 rate of 44.736 Mb/s. This Module does all of the following: • operates in unframed, Ml3, and C-bit parity environments • monitors DS3 signals using frame errors, Bipolar Violations (BPVs), and parity results • performs full Bit Error Rate Testing (BERT) on DS3s that are out-of-service • transmits and monitors Far End Alarm Control Codes (FEAC) sequences (e.g., alarm conditions and loopbacks) • inserts logic errors, frame errors, and BPVs on live traffic or test patterns. Logic errors and/or BPVs can be inserted singly or at programmable rates; frame errors can be inserted consecutively, to a maximum of 15. 1.3 INTERFACE COMPATIBIÜTY The DS3 Interface Module complies with the following publications and specifications: • Bell Publication CB119 — Interconnection Specification for Digital Cross-Connects • ANSI Specification Tl.404 • CCITT 44.736 MB/S RECOMMENDATIONS — APPLICABLE SECTIONS OF G.703

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
65
Rozmiar:
2.51 Mbytes (2635636 Bytes)
Język:
english
Rewizja:
A
Ręczny ID:
ML12029
Data:
1993 03 01
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2017 01 08
MD5:
2bba231e09c16bc056f260eff13daa74
Pobrane:
644

Informacja

1.0 GENERAL INFORMATION ... 1 1.1 MANUAL SUMMARY ... 1 1 1.2 DS3 Interface MODULE OVERVIEW ... 1 i 1.3 INTERFACE COMPATIBILITY ... 1 1.4 CABLES ... , ... 1 | 2.0 PHYSICAL DESCRIPTION ... 3 2.1 INTRODUCTION ... 3 1 2.2 PHYSICAL DESCRIPTION ... 3 I 2.3 FUNCTIONAL DESCRIPTION ... 4 . 2.4 SELF-LOOP OPERATION ... 4 I 3.0 FIREBERD 6000 INSTALLATION AND OPERATION ... 5 fc 3.1 INTRODUCTION ... 5 3.2 INSTALLING THE INTERFACE ... 5 I 3.3 CONFIGURING THE DS3 Interface MODULE FOR FIREBERD 6000 OPERATION ... 6 ! 3.4 THE DS3 Interface MODULE SET-UP MENU ... 6 3.5 FIREBERD 6000 TEST RESULTS ... 11 3.6 INTERFACE STATUS INDICATORS ... 15 3.7 FIREBERD 6000 PRINTER OPERATION ... 15 3.8 FIREBERD 6000 REMOTE CONTROL COMMANDS ... 17 4.0 FIREBERD 6000 APPLICATIONS ... 19 4.1 INTRODUCTION ... 19 4.2 IN-SERVICE MONITORING ... 19 4.3 OUT-OF-SERVICE TESTING ... 23 5.0 FIREBERD 4000 INSTALLATION AND OPERATION ... 33 5.1 INTRODUCTION ... 33 5.2 INSTALLING THE INTERFACE ... 33 5.3 CONFIGURING THE DS3 Interface MODULE FOR FIREBERD 4000 OPERATION ... 34 5.4 THE DS3 Interface MODULE SET-UP MENU ... 34 5.5 FIREBERD 4000 TEST RESULTS ... 40 5.6 INTERFACE STATUS INDICATORS ... 43 5.7 FIREBERD 4000 PRINTER OPERATION ... 43 5.8 FIREBERD 4000 REMOTE CONTROL COMMANDS ... 44 6.0 FIREBERD 4000 APPLICATIONS ... 47 6.1 INTRODUCTION ... 47 6.2 IN-SERVICE MONITORING ... 47 6.3 OUT-OF-SERVICE TESTING ... 51 7.0 SPECIFICATIONS ... ; ... 59 7.1 INTRODUCTION ... 59 8.0 MAINTENANCE AND SERVICE ... ,, ... 61 8.2 MAINTENANCE ... - ... 61 8.3 SERVICE ... 61 APPENDICIES APPENDIX A FACTORY DEFAULT SETTINGS ... APPENDIX B M13 AND C-BIT FRAMING FORMATS

pokaż więcej