Keithley 195A Multimetr cyfrowy
Producent:
Model:
195A
Data:
Kategoria:
Grupa:
Opis:

Informacja

The Model 195A Digital multimeter is a fully programmable instrument with 5½ digit resolution. In standard configuration, the Model 195A is capable of DC voltage measurements between 100nV and 1000V on six ranges, 2-terminal and 4-terminal resistance measurements between 100µΩ and 20MΩ on seven ranges and temperature measurements in the range of -220°C and +630°C and between -360°F and + 1100°F. The instrument is designed to work with platinum RTD probes, a factor which contributes to high accuracy. With the optional Model 1950 ACV and AC and DC current option installed, the Model 195A can make TRMS AC voltage measurements between 1/A/ and 700V on five ranges, TRMS AC current measurements between 1nA and 2A on five ranges and DC current measurements between 100pA and 2A on six ranges. The versatility of the Model 195A DMM is further enhanced by the inclusion of a standard IEEE-488 Interface. A highlight of Model 195A operation is its digital calibration feature which allows the user to easily perform calibration from the front panel. 1.2 MODEL 195A FEATURES Some important Model 195A features include: 1. Standard IEEE-488 Interface. A standard IEEE-488 interface allows the Model 195A to be programmed from a system controller; readings may also be transmitted over the bus to other instrumentation in the talk-only mode. 2. Front Panel Programs. Numerous internal programs to control various operating modes such as digital calibration and IEEE-488 parameters are easily entered from the front panel. 3. Non-Volatile (NV) RAM Storage. A non-volatile RAM stores calibration constants, certain IEEE operating parameters, and line frequency values even when the power is turned off. 4. Digital Calibration. The Model 195A may be easily calibrated by applying an appropriate calibration signal and running the front panel calibration program or by commanding it over the bus. The calibration level may be at full range, or at some value entered from the front panel or over the IEEE bus. 5. Data Storage. A data storage buffer is included to allow up to 100 readings to be internally stored at a user-selected rate. The buffer may be read and controlled from the front panel or over the IEEE-488 bus. In the talk-only mode, the output rate can also be programmed. 6. Front and Rear Panel Input Terminals. Input terminals are duplicated on the front and rear panels to allow easy connections in both bench and rack-mounted situations. The selected set of inputs is controlled by the rear panel sw'itch. 7. Trigger Input and Output. The Model 195A may be triggered to take readings by applying an external trigger pulse or by pushing a front panel button. A separate output pulse, which is active w'hen the instrument completes a reading, is also available on the rear panel. 8. Auto Ranging. The Model 195A includes a fast auto ranging feature for easier measurements. 9. Front Panel Zero. A single front panel zero control allows the user to store a separate zero offset for each measuring function. 10. Filtering. Digital filtering is selectable from the front panel or bus.

pokaż więcej

Serwis i User Manual
Typ ręczny:
Serwis i User Manual
Strony:
154
Rozmiar:
8.91 Mbytes (9344217 Bytes)
Język:
english
Rewizja:
Ręczny ID:
195A-901-01
Data:
1984 01 01
Jakość:
Skanowany dokument, wszystko czytelne.
Data przesłania:
2018 08 21
MD5:
285c8c4ccc49d7c6e6d2ddeb06b42075
Pobrane:
986
Serwis i User Manual
Typ ręczny:
Serwis i User Manual
Strony:
138
Rozmiar:
13.81 Mbytes (14484608 Bytes)
Język:
english
Rewizja:
F
Ręczny ID:
195A-901-01
Data:
Jakość:
Skanowany dokument, wszystko czytelne.
Data przesłania:
2014 03 02
MD5:
32821c18898b4a4f70f33ef77a29bbdc
Pobrane:
1426
Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
11
Rozmiar:
333.92 Kbytes (341930 Bytes)
Język:
english
Rewizja:
Ręczny ID:
Data:
Jakość:
Skanowany dokument, czytając częściowo źle, nie częściowo czytelny.
Data przesłania:
2018 08 21
MD5:
528623489571773e07831e821a45ac93
Pobrane:
676

Informacja

Programming Instructions CONDENSED SPECIFICATIONS ... 2 MODEL 195A FEATURES ... 3 FRONT PANEL PROGRAMS ... 5 IEEE-488PROGRAMMING ... 6 PROGRAM ... 10 Apple II (Apple Interface) ... ig DEC LS111 ... ^ HP-85 ... X2 HP-9825A ... 13 HP-9816 ... 14 HP-9845B ... -}4 PET/CBM2Q01 ... 15 TEK 4052 ... 16 IBM PC or XT Personal Computer ... 17 (National Instruments} E-H 7000 Computer

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
19
Rozmiar:
333.52 Kbytes (341526 Bytes)
Język:
english
Rewizja:
Ręczny ID:
195A-903-01A
Data:
Jakość:
Skanowany dokument, czytając częściowo źle, nie częściowo czytelny.
Data przesłania:
2014 03 07
MD5:
d96d484e83789ccb9b7e6ef534a36f28
Pobrane:
872

Informacja

Programming Manual

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
11
Rozmiar:
332.49 Kbytes (340471 Bytes)
Język:
english
Rewizja:
Ręczny ID:
195A-903-01A
Data:
1984
Jakość:
Skanowany dokument, wszystko czytelne.
Data przesłania:
2023 06 13
MD5:
e7a841691c910b47680853b8fb7bdfec
Pobrane:
46