Fluke 752A Ander
Fabrikant:
Model:
752A
Datum:
1984
Categorie:
Groep:
Omschrijving:
Reference Divider

Informatie

The John Fluke Model 752A is a self-calibrating, precision dc voltage divider with two ranges of division: 10:1 and 100:1. In addition to the two divider ranges, the 752A incorporates switching modes used in the cardinal point calibration of dc voltage calibrators. The points provided on the 752A are 0.1V, IV, 10V, 100V, and 1000V. When the 752A is combined with a dc voltage Calibrator, a 10V reference standard, and a null detector, the 752A switches the equipment to standardize the dc voltage Calibrator without having to physically change the leads. 1-3. The 752A is self-calibrated before each use. This procedure requires a stable source and a null detector. The 752A is a ratio device only, and does not have to be included in a calibration cycle that is traceable to an external standard. 1 -4. The front panel MODE switch selects between self- calibration and normal operation. In the Self-Calibration mode, the voltage divider resistors are compared using an external null detector to an internal, self-calibrating bridge to precisely set their overall value, and hence, the division ration of the 752A, The three push-to-tum CALIBRATE controls adjust the 10:1 divider, 100:1 divider, and the self-calibration bridge. The CALIBRATE switch selects the divider to be calibrated and interchanges the two resistors in the self-calibration bridge to check that they are of equal value. If not, the BALANCE control adjusts one of these resistors by a small amount to make both selfcalibration bridge resistors equal in value. 1-5. In normal operation, the MODE switch settings correspond to the cardinal calibration points of a dc voltage calibration system. The MODE switch now interconnects the external equipment in one of three ways (refer to Figure 2-3): 1. The voltage divider of the 752A is connected between the reference standard and the null detector as shown in Figures 2-3a and 2-3b. 2. The voltage divider is out of the circuit and the reference standard is compared directly with the UUT (unit under test) as shown in Figure 2-3c. 3. The voltage divider is connected between the UUT and the null detector as shown in Figures 2-3d and 2-3 e.

toon meer

Service-en gebruikershandleiding
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
65
Grootte:
5.14 Mbytes (5385347 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
645069
Datum:
1984 04 01
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
2017 02 04
MD5:
ca66e184dd5ddf9ab3c53680e7362572
Downloads:
739

Informatie

1 INTRODUCTION AND SPECIFICATIONS 1-1 1-1. INTRODUCTION ... 1-1 1-7. SPECIFICATIONS AND ACCESSORIES ... 1-1 2 OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SHIPPING INFORMATION ... 2-1 2-5. INSTALLATION ... 2-1 2-7. INPUT LINE POWER ... 2-1 2-9. FRONT AND REAR PANEL FEATURES ... 2-1 2-11. OPERATING NOTES ... 2-1 2-12. Introduction ... 2-1 2-14. Guard/Ground Terminals ... 2-1 2-17. Self-Calibration Procedure ... 2-1 2-19. OPERATION ... 2-4 2-20. Introduction ... 2-4 2-22. Calibration System Operation ... 2-4 2-24. Stand Alone Operation ... 2-4 3 THEORY OF OPERATION ... ... 3-1 3-1 INTRODUCTION ... 3-1 3-3. OVERALL FUNCTIONAL DESCRIPTION ... 3-1 3-6. System Operation ... 3-1 3-8. Stand-Alone Operation ... 3-2 3-10. VOLTAGE DIVIDER CIRCUIT ... 3-2 3-14. MODE SWITCH ... 3-2 3-16. SELF-CALIBRATION CIRCUIT ... 3-2 3-23. GUARD CIRCUITS ... 3-4 3-26. ERROR ANALYSIS ... 3Λ 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-5. SERVICE INFORMATION ... 4-1 4-9. GENERAL MAINTENANCE ... 4-2 4-10. Introduction ... 4-2 4-12. Cleaning ... 4-2 4-16. Internal Repair ... 4-2 4-18. Access Procedure ... 4-2 4-30. PERFORMANCE CHECKS ... 4-7 4-32. INTERNAL CALIBRATION (Long-Term Drift Corr.) ... 4-7 4-34. Self-Calibration Bridge Long-Term Drift Correction Procedure ... 4-7 4-36. Self-Calibration Bridge Long-Term Drift Correction Example ... 4-7 4-39. 10:1 Divider Long-Term Drift Correction Procedure ... 4-8 4-41. 10:1 Divider Drift Correction Example ... 4-9 4-44. 100:1 Divider Long-Term Drift Correction Procedure ... 4-10 4-46. TROUBLESHOOTING ... 4-11 5 LIST OF REPLACEABLE PARTS ... 5-1 5-1. INTRODUCTION ... 5-1 5-4. HOW TO OBTAIN PARTS ... 5-2 6 ACCESSORIES ... 6-1 INTRODUCTION ... 6-1 6-3. DUAL MOUNTING FASTENERS (M00-800-5237) ... 6-1 6-5. HALF-WIDTH RACK MOUNT KIT (M07-203-601) ... 6-1 6-7. FULL-WIDTH RACK MOUNT KIT ( M07-200-603) ... 6-1 7 GENERAL INFORMATION ... 7-1 7A MANUAL BACKDATING INFORMATION ... 7A-1 8 SCHEMATIC DIAGRAMS ... 8-1 INDEX ... 8-12 NO SCHEMATICS!

toon meer