Fluke 410B Voeding
Fabrikant:
Model:
410B
Datum:
1965
Categorie:
Groep:
Omschrijving:
DC Power Supply

Informatie

The Fluke Model 410B High Voltage DC Power supply is capable of providing an output of 0 to 10, 000 vdc at 0 to 10 milliamperes. The output voltage is selected by four decade switches and a vernier potentiometer. The instrument may be operated with either positive or negative output terminal grounded, as selected by a front-panel switch. Overcurrent protection is provided to return the supply to standby operation in the event of excessive load current. 1-4. The Model 410B is a hybrid design utilizing silicon transistors for the Amplifier circuitry and a vacuum tube for the necessary high voltage series passing element. A time-delay relay is incorporated in the input circuitry, which prolongs the life of the high voltage passing tube. The reference element is a highly stable temperature compensated gas tube. 1-5. The package design provides for adequate cooling at high ambient temperatures without the use of cooling fans. Rubber feet are provided for bench top operation to permit unrestricted air flow through the bottom cover air vents. The front panel is punched for mounting in a standard 19 inch rack. Side panels are tapped for Jonathan #130 quick disconnect chassis slides or other rack mounting supports.

toon meer

Gegevensblad
Handleidingen type:
Gegevensblad
Pagina’s:
2
Grootte:
153.76 Kbytes (157455 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
2016 01 28
MD5:
05ee9c36b94ff9c66794b1aaa3ccf12b
Downloads:
772
Servicehandboek
Handleidingen type:
Servicehandboek
Pagina’s:
54
Grootte:
2.27 Mbytes (2383704 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
294009
Datum:
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
2016 01 31
MD5:
2d50679a3fdc9f4437508d96d213fead
Downloads:
817

Informatie

I INTRODUCTION AND SPECIFICATIONS 1-1 1-1. Introduction ... 1-1 1-2. General Description ... 1-1 1-6. Receiving Inspection ... 1-1 1-8. Specifications ... 1-1 1-9. Electrical ... 1-1 1-10. Mechanical ... 1-1 H OPERATING INSTRUCTIONS 2-1 2-1. Function of External Controls, Terminals, and Indicators ... 2-1 2-3. Input Power ... 2-1 2-5. Initial Operation ... 2-2 2-7. General Purpose Use ... 2-2 2-8. Use As A Calibrator ... 2-2 2-10. Direct Calibration ... 2-3 2-11. Precision Calibration ... 2-3 2-12. Notes on Operation ... 2-3 2-13. Meter Accuracy ... 2-3 2-15. Overload Protection ... 2-4 2-17. Polarity Switching ... 2-4 2-19. Coaxial Cable Assembly ... 2-4 2-23. Amphenol MS 3106A Connector Assembly . 2-5 in THEORY OF OPERATION 3-1 3-1. Introduction ... 3-1 3-3. Overall Operation ... 3-1 3-5. Circuit Descriptions ... 3-1 3-6. Controls Relays ... 3-1 3-8. Overcurrent Protection ... 3-2 3-10. Main Output Voltage ... 3-2 3-12. Feedback Amplifier ... 3-2 3-14, Auxiliary Supplies ... 3-2 3-16. Reference Voltage ... 3-2 3-18. Accuracy ... 3-2 IV MAINTENANCE 4-1 4-1. Introduction ... 4-1 4-3. Preventive Maintenance ... 4-1 4 - 6. T roub le s hooting ... 4-1 4-9. Auxiliary ... 4-1 4-10. Line Regulation and Ripple ... 4-1 4-11. Load Regulation ... 4-3 4-12. Stability ... 4-3 4-13. Output at Zero Volts ... 4-4 4-14. Calibration ... 4-4 4-16. Reference Current Adjustment ... 4-4 4-17. Overcurrent Trip Adjustment ... 4-4 4-18. Meter Calibration ... 4-4 V LIST OF REPLACEABLE PARTS 5-1 5-1. Introduction ... 5-1 5-4. How To Obtain Parts ... 5-1 5-7. Abbreviations ... 5-2 5-8. Prefix Symbols ... 5-2 5-9. Quantity Symbols ... 5-2 5-10, Special Notes and Symbols ... 5-2 5-11. Use Code Effectivity ... 5-15 VI NOT APPLICABLE VII GENERAL INFORMATION ... 7-1 7-1. List of Abbreviations . . . . ... 7-1 7-2. Federal Supply Codes for Manufacturers ... 7-3 7-3. Fluke Technical Service Centers ... 7-10 7-4, Sales Representatives - Domestic ... 7-11 7-5. Sales Representatives - International ... 7-13 VIII SCHEMATIC DIAGRAMS ... 8-1

toon meer