California Instruments 503T Voeding
Fabrikant:
Model:
503T
Datum:
1986
Categorie:
Groep:
Omschrijving:
Power Source

Informatie

The California Instruments Model 503T is a solid state, high performance, low distortion power source that provides up to 500 VA the three phase power when used with the proper California Instruments Oscillator. The Model 503T Three Phase Power Source is illustrated in Figure 1- 1. Full power output is available in five different voltage ranges and over the frequency range from.45 Hz to 5 KHz. The output voltage range is normally determined at the factory prior to shipment of the unit, however it can be accomplished in the field, if required. The full power ranges are; 1) 23, 4 to 30 volts rms line-to-neutral in a three phase output configuration. This provides 40* 5 volts to 52 volts rms line-to-line at 167 VA per phase (500 VA total). 2) 35. 1 to 45 volts rms line-to-neutral in a three phase output configuration. This provides 60. 6 volts to 78 volts rms line-to-line at 167 VA per phase (500 VA total). 3) 58. 5 to 75 volts rms line - to-neutral in a three phase output configuration. This provides 102 volts to 130 volts rms line-to-line at 167 VA per phase (500 VA ..........total)...,....................................................................................................... 4) 105 to 135 volts rms line-to-neutral in a three phase output configuration. This provides 182 volts to 234 volts rms line-to-line at 167 VA per phase (500 VA total). 5) 105 to 135 volts rms single phase output at 500 VA. The serial number tag, located on the rear of the Model 503T Power Source, indicates the output voltage range which the unit is wired for at the time of shipment.

toon meer

Service-en gebruikershandleiding
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
84
Grootte:
2.87 Mbytes (3006313 Bytes)
Taal:
english
Herziening:
J
Handleidingen-ID:
4053-960
Datum:
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
2015 12 20
MD5:
59d877f3b0dcdbbc0487a16cb94a1250
Downloads:
580

Informatie

GENERAL DESCRIPTION 1.1 INTRODUCTION 1 1. 2 GENERAL DESCRIPTION 1 1.3 ACCESSORY EQUIPMENT 2 INSTALLATION AND OPERATION 2.1 UNPACKING 7 2.2 POWER REQUIREMENTS 7 2. 3 CIRCUIT BREAKER REQUIREMENTS 8 2.4 OUTPUT VOLTAGE RANGE 8 2.5 METER RANGE 10 2„ 6 ACCEPTANCE TEST PROCEDURE 10 2* 7 MECHANICAL INSTALLATION 11 2.8 INPUT POWER WIRING 12 2.9 OUTPUT POWER WIRING 12 2. 10 FRONT PANEL CONTROLS 12 2* 11 OPERATION OVER EXTENDED FREQUENCY RANGE I2A THEORY OF OPERATION 3.1 GENERAL 13 3. 2 DETAILED CIRCUIT DESCRIPTION 15 CALIBRATION PROCEDURE 4.1 ... GENERAL 21 4* 2 TEST EQUIPMENT REQUIRED 23 47 3 ... INITIAL ADJUSTMENTS ... 23 4. 4 OVERLOAD ADJUSTMENT 25 4. 5 GAIN ADJUSTMENT 27 4. 6 AC LINE INPUT POWER 27 4. 7 OUTPUT VOLTAGE, POWER OUTPUT AND HARMONIC DISTORTION 2? 4. 8 ■ LINE REGULATION 28 4, 9 LOAD REGULATION ADJUSTMENT 30 4. 10 AMPLITUDE STABILITY 31 4. 11 FREQUENCY RESPONSE 32 4„ 12 AC NOISE LEVEL 32 4. 13 0. 7 LAGGING POWER FACTOR 33 4„ 14 0.7 LEADING POWER FACTOR 36 4. 15 PHASE ACCURACY 3o MAINTENANCE AND TROUBLESHOOTING 5. 1 GENERAL 38 5.2 TROUBLESHOOTING 38 CIRCUIT DIAGRAM 6. 1 GENERAL 39 6. 2 REFERENCE DESIGNATIONS 39 REPLACEABLE PARTS 7.1 GENERAL 40 7.2 ORDERING INFORMATION 40 PARTS LIST . APPENDIX A CODE LIST OF MANUFACTURERS

toon meer