LeCroy 9314C Oscilloscopio
Produttore:
Nessuna immagine disponibile!
Forse puoi caricare una foto per la
LeCroy 9314C?
Se avete altri manuali per la
LeCroy 9314C potete caricare i file qui .
Modello:
9314C
Data:
1994
Categoria:
Gruppo:
Descrizione:
Digital Storage Oscilloscope
Informazioni
The 9310A family forms a range of ideal general-purpose
digital oscilloscopes. They capture single-shot events
at up to 100 MSamples/s, and repetitive signals at
10 GSamples/s. Record lengths up to 1M points provide
high-quality horizontal resolution, and allow fast
digitizing of long-duration events. Memories can be
segmented, for minimum dead time between acquisitions.
Live waveforms may be viewed simultaneously with up
to 3 expansions, showing all of the signal detail.
Expansions are shown as highlights on the main trace.
The LeCroy ProBus™ intelligent Probe system allows
automatic sensing of the Probe type. For LeCroy's
active FET probes it also provides variable offset at
the Probe tip; offset and coupling are controlled
from the scope front panel.
SMART Trigger modes like Glitch, Window and Dropout
allow you to capture precisely the events of interest.
A comprehensive range of signal processing functions,
on live or stored waveforms, allows waveform manipulation
without destroying the underlying data.
The 9310A family features the proven user-interface
of LeCroy's portable scope family. A bright, high-resolution
9" CRT allows optimum waveform viewing under any conditions.
Menus and text are arranged around the graticules -they
never overwrite the waveforms. Each of the main control
functions has a dedicated single knob, to keep the scope’s
performance at your fingertips.
DOS compatible floppy disk and memory card options
store waveforms and test setups, and make transferring
data to a PC easier than ever before. Hardcopies may
be made on GPIB, RS-232-C or Centronics printers or
plotters. An optional internal printer is also available.
Optional packages provide extensive Waveform Processing
including FFT and Enhanced Resolution to 11 bits.
Tipo di manuale:
Manuale d'uso
Pagine:
275
Dimensione:
5.49 Mbytes (5758060 Bytes)
Lingua:
english
Revisione:
A
ID del manuale:
93XXC-OM-E
Data:
1998 01 01
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2021 01 10
MD5:
6c2570da8f4b0b75a9fe55b62240b2b7
Scaricamenti:
1500
Informazioni
Chapter 1 — Read This First!
Product and Client Care ... 1–1
Chapter 2 — Instrument Architecture
General Designed Capabilities ... 2–1
Block Diagrams ... 2–4
Chapter 3 — Installation and Safety
Installation for Safe and Efficient Operation ... 3–1
Chapter 4 — Introduction to the Controls
The Front Panel ... 4–1
The Main Controls ... 4–3
Choosing and Navigating in Menus ... 4–4
System Setup and Menu Controls ... 4–6
Screen Topography ... 4–8
Chapter 5 — CHANNELS, Coupling and Probes
Channel Controls ... 5–1
Coupling ... 5–3
Probes and Probe Calibration ... 5–4
Chapter 6 — TIMEBASE + TRIGGER
TIMEBASE + TRIGGER Controls ... 6–1
Chapter 7 — Timebase Modes and Setup
Timebase Sampling Modes ... 7–1
Timebase Setup ... 7–5
Chapter 8 — Triggers and When to Use Them
Choosing the Right Trigger ... 8–1
Edge or SMART? ... 8–2
Edge Trigger ... 8–3
TRIGGER SETUP: Edge ... 8–9
SMART Triggers ... 8–10
TRIGGER SETUP: SMART ... 8–29
Chapter 9 — ZOOM + MATH
Zoom and Math Controls ... .9–1
Chapter 10 —Zoom, Mathematics and Math Setup
Zooming for Precise Waveform Measurements ... 10–1
Math Functions and Options ... 10–2
Using Waveform Mathematics ... 10–5
Configuring for Zoom and Math ... 10–6
Setting Up FFT Span and Resolution ... 10–17
Chapter 11 — Display
Chapter 12 — UTILITIES
Setting Up the Display ... 11–1
Printing, Storing, Using Special Modes ... 12–1
Hardcopy Setup ... 12–2
Time/Date Setup ... 12–4
GPIB/RS232 Setup ... 12–5
Mass Storage Utilities ... 12–7
Special Modes ... 12–19
CAL BNC Setup ... 12–21
Chapter 13 —WAVEFORM STORE & RECALL
Waveform Store ... 13–1
Waveform Recall ... 13–4
Chapter 14 — CURSORS/MEASURE & Parameters
Cursors: Tools for Measuring Signal Values ... 14–1
Parameters: Automatic Measurements ... 14–4
Pass/Fail Testing ... 14–13
Chapter 15 — PANEL SETUPS
Saving and Recalling Panel Setups ... 15–1
Chapter 16 — SHOW STATUS
The Complete Picture — Summarized ... 16–1
Appendix A — Specifications
Appendix B — Enhanced Resolution
Appendix C — Fast Fourier Analysis (FFT)
Appendix D — Parameter Measurement
Appendix E — ASCII-Stored Files
Tipo di manuale:
Manuale d'uso
Pagine:
258
Dimensione:
4.24 Mbytes (4450391 Bytes)
Lingua:
english
Revisione:
A
ID del manuale:
93XXC-OM-E
Data:
1998 01 01
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2021 01 06
MD5:
983846db70dcc29334cd96888a6627a0
Scaricamenti:
1305
Informazioni
Chapter 1 — Read This First!
Product and Client Care ... 1–1
Chapter 2 — Instrument Architecture
General Designed Capabilities ... 2–1
Block Diagrams ... 2–4
Chapter 3 — Installation and Safety
Installation for Safe and Efficient Operation ... 3–1
Chapter 4 — Introduction to the Controls
The Front Panel ... 4–1
The Main Controls ... 4–3
Choosing and Navigating in Menus ... 4–4
System Setup and Menu Controls ... 4–6
Screen Topography ... 4–8
Chapter 5 — CHANNELS, Coupling and Probes
Channel Controls ... 5–1
Coupling ... 5–3
Probes and Probe Calibration ... 5–4
Chapter 6 — TIMEBASE + TRIGGER
TIMEBASE + TRIGGER Controls ... 6–1
Chapter 7 — Timebase Modes and Setup
Timebase Sampling Modes ... 7–1
Timebase Setup ... Chapter 8 — Triggers and When to Use Them
Choosing the Right Trigger ... 8–1
Edge or SMART? ... 8–2
Edge Trigger ... 8–3
TRIGGER SETUP: Edge ... 8–9
SMART Triggers ... 8–10
TRIGGER SETUP: SMART ... 8–29
Chapter 9 — ZOOM + MATH
Zoom and Math Controls ... .9–1
Chapter 10 —Zoom, Mathematics and Math Setup
Zooming for Precise Waveform Measurements ... 10–1
Math Functions and Options ... 10–2
Using Waveform Mathematics ... 10–5
Configuring for Zoom and Math ... 10–6
Setting Up FFT Span and Resolution ... 10–17
Chapter 11 — Display
Chapter 12 — UTILITIES
Setting Up the Display ... 11–1
Printing, Storing, Using Special Modes ... 12–1
Hardcopy Setup ... 12–2
Time/Date Setup ... 12–4
GPIB/RS232 Setup ... 12–5
Mass Storage Utilities ... 12–7
Special Modes ... 12–19
CAL BNC Setup ... 12–21
Chapter 13 —WAVEFORM STORE & RECALL
Waveform Store ... 13–1
Waveform Recall ... 13–4
Chapter 14 — CURSORS/MEASURE & Parameters
Cursors: Tools for Measuring Signal Values ... 14–1
Parameters: Automatic Measurements ... 14–4
Pass/Fail Testing ... 14–13
Chapter 15 — PANEL SETUPS
Saving and Recalling Panel Setups ... 15–1
Chapter 16 — SHOW STATUS
The Complete Picture — Summarized ... 16–1
Appendix A — Specifications
Appendix B — Enhanced Resolution
Appendix C — Fast Fourier Analysis (FFT)
Appendix D — Parameter Measurement
Appendix E — ASCII-Stored Files
Tipo di manuale:
Manuale di servizio
Pagine:
428
Dimensione:
10.96 Mbytes (11491922 Bytes)
Lingua:
english
Revisione:
first edition
ID del manuale:
Data:
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2013 01 26
MD5:
a07fccce52b929acf03bd46b1b11a83d
Scaricamenti:
4975