IFR 6970 Metro di livello
Produttore:
Modello:
6970
Data:
1999
Categoria:
Gruppo:
Descrizione:
RF Power Meter

Informazioni

The 6970 Power Meter comprises a plastic case moulded in two sections. The electronic circuits are located on two multi-layer PCBs using surface mounted components. The upper case section has the LCD PCB secured inside with the LCD visible through an aperture. The keypad assembly uses metal dome spring keys in a layered construction which is adhesively fixed to the case upper surface. Three NiCd rechargeable batteries are held in clips on the PCB. The lower case section has the Main PCB secured inside. The SENSOR INPUT multi-pin connector, fitted to the aluminium/polycarbonate front panel, is located in a groove at the top end of the case assembly. The DC input connector is similarly located at the bottom end of the case, with a voltage regulator heat sink plate attached to it. The Power Reference PCB is secured inside the upper section of the case, and is fixed to the LCD PCB. The power reference output N-type connector is located on the front panel of the case, next to the previously mentioned SENSOR INPUT connector. SYSTEM DESCRIPTION The heart of the 6970 Power Meter is an 8-bit microcontroller which provides control and timing for the unit and processes measurement data acquired through an analogue/digital Converter (ADC), it also drives the liquid crystal display (LCD) and interfaces which the keypad. Program code is contained in internal ROM. The 6970 uses a signal chopper to provide a pulsed DC voltage which is proportional to the incident RF power and thus allows AC coupled differential amplification. The tuned input Amplifier is distributed between the selected sensor and the 6970 input Amplifier, as shown in Fig. 1-1. The second stage Amplifier scales the signal as appropriate over four ranges before feeding the ADC, which converts the analogue signal to digital form suitable for the microcontroller to process and apply corrections. A digital/analogue Converter (DAC) is used as part of the sensor zero operation to minimize and account for system offsets when no RF signal is applied. The internal power source comprises three rechargeable NiCd cells; two DC-DC converters are used to boost the NiCd power source to regulated +5 V and -5 V power rails required by the analogue and digital circuitry. The optional power reference provides a 0 dBm (lmW) 50 MHz signal from a level controlled Oscillator based on a dual gate FET. Thermal compensation techniques are used in the design of the Oscillator such that long term drift of output power due to temperature variations are minimised.

mostra più dettagli

Manuale d'uso
Tipo di manuale:
Manuale d'uso
Pagine:
48
Dimensione:
401.35 Kbytes (410978 Bytes)
Lingua:
english
Revisione:
Issue 12
ID del manuale:
46882-182
Data:
2000 02 23
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2016 06 05
MD5:
bf94901c106dbdb26cb80216157ca4ad
Scaricamenti:
678

Informazioni

CONVENTIONS ... 1-1 PURPOSE AND FEATURES OF EQUIPMENT ... 1-1 ACCURACY ... 1-2 OPERATIONAL FACILITIES ... 1-2 PERFORMANCE DATA ... 1-3 OPTIONS AND ACCESSORIES ... 1-6 SUPPORTED POWER SENSORS ... 1-6

mostra più dettagli

Manuale di servizio
Tipo di manuale:
Manuale di servizio
Pagine:
75
Dimensione:
23.97 Mbytes (25136391 Bytes)
Lingua:
english
Revisione:
5
ID del manuale:
46882-207T
Data:
1999 01 01
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2020 05 17
MD5:
c05cc89f57b0a880cd12f6f0ea76b945
Scaricamenti:
562

Informazioni

Chapter 1 TECHNICAL DESCRIPTION Chapter 2 MAINTENANCE Chapter 3 ADJUSTMENT & CALIBRATION Chapter 4 INITIAL REPAIR Chapter 5 FAULT DIAGNOSIS Chapter 6 REPLACEABLE PARTS Chapter 7 SERVICING DIAGRAMS

mostra più dettagli