Fluke 6160B Generatore
Produttore:
Modello:
6160B
Data:
1973
Categoria:
Gruppo:
Descrizione:
Synthesized RF Signal Generator

Informazioni

The Fluke 6160B Frequency Synthesizer is the industry’s most popular VHF Synthesizer because of its high spectral purity. It produces frequencies from 1 MHz to 160 MHz in two ranges: 1 MHz to 12 MHz and 10 MHz to 160 MHz. Frequency resolution is 0.1 Hz on the 12 MHz range and 1.0 Hz on the 160 MHz range. A unique feature of the 6160B is that the highest internally-generated frequency is that of the output VCO, i.e., 80 to 160 MHz. This makes servicing easier, and eliminates UHF EMC problems. Since the output VCO operates from 80 to 160 MHz, frequency division is employed for coverage of lower frequencies. This results in improved spurious specifications for frequencies lower than 80 MHz. Phase noise is similarly reduced for lower bands. Built-in remote programming is DTL/TTL, BCD, positive true logic or by contact closures. Programming of frequency is via 34 parallel lines, and a remote flag and power flag are provided. Switching is fast, output level is electrically adjustable. Compatibility with GPIB/IEEE-488*- 1978 is achieved using the Fluke 1120A Translator and 6XXXA-529 Interface.

mostra più dettagli

Servizio e manuale utente
Tipo di manuale:
Servizio e manuale utente
Pagine:
252
Dimensione:
10.13 Mbytes (10619878 Bytes)
Lingua:
english
Revisione:
1
ID del manuale:
332028
Data:
1974 07 01
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2018 01 20
MD5:
cb366e3e546d493dfbf9886a11cdcba4
Scaricamenti:
753

Informazioni

1 INTRODUCTION AND SPECIFICATIONS ... H. INTRODUCTION ... 1-6. SPECIFICATIONS ... 2 OPERATING INSTRUCTIONS ... 2-1. INTRODUCTION ... 2-3. SHIPPING INFORMATION ... 2-6. INPUT POWER ... 2-8. INSTALLATION ... 2-10. operating features ... 2-12. OPERATING NOTES ... 2-13. AC Line Connection ... 2-16. Drive Source ... 2-19. External Amplitude Control ... 2-21. OPERATIONAL TESTS ... 2-24f OPERATION ... 2-25. Frequency Selection ' , - - , , , . . . 2-27. Amplitude Control * - , . * ... - 2-29. Fixed Output ... 2-31. Remote Control ... 3 THEORY OF OPERATION ... 3-1. INTRODUCTION ... 3-5. SIMPLIFIED BLOCK DIAGRAM DESCRIPTION . 3-7. FUNCTIONAL BLOCK DIAGRAM DESCRIPTION 3-9. Frequency Standard ... 3-11. Input Filter ... 3-14. Computer 3-18. Digit Generator ... 3-33, CIRCUIT DESCRIPTIONS ... 3^6 3-35. Front Panel PCB Assembly (6I6ÜB405 1) ... 3-6 3-41. Power Supply (6160A4014) ... 3-7 3-48, 5 MHz Frequency Standard (6160A4018) , , , 3*8 3-5L Input Filter Module (6160A-4101) ... 3,8 3-54, Six Digit Generator (6040A-4102) ... 3.9 3-65. 1 MHz Digit Generator ... 3,]! 3-72, 10 MHz D,U, Step Loop VCO Module (6160A-41Ü7-1) 3,13 3-82. 10 MHz D.U. Step Loop P.D. Module (6160A-4106-1) 3.15 3-92 10 MHz D.U. IF Mixer Module (6160A-4108) . . . 3-17 3-96, 10 MHz D.U. Main P.D. Module (6160A-4109) . . 3-19 3-104, 10 MHz D,U, Main Loop VCO Module(6160A-4110). 3-20 3-UO, Output Divider Module (6160A-4111) ... 3-21 3-134, Computer Assembly (6160B4012) ... 3-26 4 MAINTENANCE ... 4-1 4-1, INTRODUCTION ... 4-1 44. SERVICE INFORMATION ... 4-1 4-7. MAINTENANCE ACCESS ... 4-2 4-8. Major Section Access ... 4-2 4-10. Module Removal ... 4-2 4-12. Plug-in Printed Circuit Cord Removal ... 4-2 4-14. Hinged Printed Circuit Assembly Access ... 4-2 4-16. Front Panel PCB Access ... 4-2 4-18. GENERAL MAINTENANCE ... 4-4 4-19, Cleaning ... 4-4 4-21, Fuse Replacement ... 44 4-23. Lamp Replacement ... 4-4 4-25. OPERATIONAL CHECKS AND ADJUSTMENTS . . 44 4-27. Front Panel ... 4-4 4-28, Power Supplies ... 4-6 4-29. Local Frequency Control ... 4-6 4-30. Remote Frequency Control ... 4-6 4-31. 5 MHz Output ... „ ... 4-6 4-32. RF Output Level ... 4-8 4-33. External Level Control ... 4-8 4-34. MODULE ALIGNMENT ... 4-9 4-37, Alignment or Test Signals ... 4-9 4-39. Power Supply Regulator Assembly (6160A-4014), . 4-9 442. Input Filter (6160A-4101) ... 4-10 4-45. 1 MHz Digit Generator Module Set (6I60B-4I53). . 4-12 4-53. Six Digit Generator (6040A4102) ... . 4-17 4-61. 10 MHz Main Loop Phase Detector (6160A-4109) . 4.19 4-64. 10 MHz Step Loop Phase Detector (6160A-4106-1) . 4.21 4-67. 10 MHz Step Loop VCO (6160A4107-1) , . . . 4.23 4-70. 10 MHz I.F. Mixer (6160A4108) ... 4.25 MODULE ALIGNMENT {continued) 4*73. 10 MHz Main Loop VCO (6160A-4110) ... 4-27 4-76. Output Divider (6160A-4111) ... 4-29 4-79. Front Panel PCB Assembly (6160A-4051) ... 4-30 4-81, TROUBLESHOOTING. . ... 4-31 5. LIST OF REPLACEABLE PARTS ... S-1 5-1. INTRODUCTION ... 5_i 5-4. PARTS LIST COLUMN DESCRIPTIONS ... 5.] 5-5. MANUFACTURERS’ CROSS REFERENCE LIST COLUMN DESCRIPTIONS ... 5-2 5-6. HOW TO OBTAIN PARTS ... 5.2 5-9, SERIAL NUMBER EFFECTIVITY ... 5.2 6. OPTION AND ACCESSORY INFORMATION ... 6-1 6-1. FREQUENCY STANDARD, OPTION -02 ... 6-1 6-2. Introduction ... 6-1 64, Operation ... 6-1 6-6. Theory of Operation ... 6-9. List of Replaceable Parts ... 6-11. REAR PANEL RF OUTPUT, OPTION -04 ... 643. TCXO, OPTION -05 . ... 7. GENERAL INFORMATION ... 7-1 8. SCHEMATIC DIAGRAMS ... 8-1

mostra più dettagli

Scheda tecnica
Tipo di manuale:
Scheda tecnica
Pagine:
2
Dimensione:
214.55 Kbytes (219698 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2016 01 28
MD5:
da121efb28f5701d1114dfd170f4ac01
Scaricamenti:
648