Fluke 6070A Generatore
Produttore:
Modello:
6070A
Data:
1982
Categoria:
Gruppo:
Descrizione:
Synthesized Signal Generator

Informazioni

THE 6070A.6071A SYNTHESIZED RF SIGNAL Generator 1-7. The John Fluke Models 6070A and 6071A Synthesized RF Signal Generators are designed for use in the calibration laboratory, engineering laboratory, or manufacturing environments. Both models offer extensive modulation capabilities and use phase-locked loop circuitry to generate fully synthesized signals with extremely low discrete spurious, and phase noise. These versatile instruments are intended for both bench and systems use. When the instrument is used in a system, all front panel control functions (except POWER and MOD OUT level) can be controlled via an IEEE-488, 1978, Interface. 1-8. Instrument parameters, such as output frequency and amplitude, can be programmed to specific values or manually adjusted using the Edit Knob (large knob near the lower right corner of the front panel). The Edit Knob is connected to a digital rotary encoder to provide the same continuous manual adjustment capability that an analog tuning control provides, but with the positive positioning of a digital control. The rotary encoder has 25 magnetic detent positions. The user can feel each position of the Edit Knob. 1-9. The major difference between the two models is that the 6071A has twice the output frequency of the 6070A, The output frequency of the 6070A can be selected within 1 Hz over a range from 200 kHz to 519.999999 Mhz (520 MHz). The output frequency of the 6071A can be selected within 1 Hz from 200 kHz to 520 MHz and within 2 Hz from 520 MHz to 1039.999998 MHz (1040 MHz). Both models can produce frequencies outside of the specified ranges, but the performance is not guaranteed. 1-10. The UNCAL annunciator will turn on to indicate that the instrument is operating beyond specified ranges. The synthesized RF signal is available at the front panel RF OUTPUT connector (if the 607XA-830 Rear Panel Output Option is installed, the RF output is available at a rear panel Type N connector). 1-11. Internal frequency reference is a 10 MHz free air timebase (the 607XA-130 Oven Reference Option is available for increased accuracy and stability). This 10 MHz reference can also be phase locked to external references of 1, 2, 2.5, 5, or 10 MHz(0.3 to 4V peak-to~peak sine or square wave) input via a rear panel BNC connector (50 Ohm input impedance, nominally). When an external reference is used, the shift from internal to external is automatic. The 10 MHz reference signal (used as the internal instrument reference) is available as a TTL signal at a rear panel REF OUT connector. 1-12. Below 520 MHz, output level can be selected with a resolution of 0.1 dB over the range of + 19 to -140 dBm (2 V to 22 nV rms) into 50 Ohms. At 520 MHz or above, output level can be selected with a resolution of 0.1 dB over the range of+13 to-140 dBm (I Vto 22 nV rms). Selected level is displayed on the front panel in either dBm or volts (the instrument will convert from one to the other if the units are changed). The internal microprocessor automatically compensates output level for flatness and accuracy although this automatic correction can be disabled (special function 81). 1-13. The RF output signal can be modulated in various combinations of amplitude modulation (AM), frequency modulation (FM), or phase modulation (0M) from internal sources, external sources, or a combination of internal and external sources. Table 1-1 lists all modulation combinations and the possible modulation sources for each combination. Amplitude modulation depth can be selected with a resolution of 0.1 % over the range of 0% to 99.9% (see the specifications for calibrated range). The frequency modulation function allows the output frequency to be deviated while the output frequency is still synthesized unless the DCFM Mode is selected. Maximum index of modulation that can be selected for either FM or 0M depends upon the output frequency and the modulation frequency selected. The internal modulation signal can be made available at the MOD OUT connectors (front and rear panels). An external modulation signal can be either ac or dc coupled through parallel connectors on the rear and front panels (MOD IN connector, 600 Ohm nominal input impedance). External input sensitivity is such that a 1 V peak input signal produces the calibrated modulation. The list of specifications at the end of this section provides detailed information about the modulation characteristics. 1-14. Up to 9 front panel setups can be stored in the internal memory of the standard instrument, but these setups are lost when the instrument is turned off. The 607XA-570 Non-Volatile Memory Option provides 50 memory locations. Since this option is battery powered, front panel setups stored in these 50 locations are not lost when the instrument is turned off. 1-15. Three outputs are available for coordinating the activity of associated devices: sweep analog output, penlift output, and output invalid output. The sweep analog output is available at the front panel SWP OUT connector. This output steps from 0 to 10V as the frequency is swept from the start frequency to the stop frequency. The size of the steps depends upon the sweep width and the sweep increment selected. The penlift output is available at a rear panel BNC connector. This output is a TTL signal that goes high during a sweep retrace and stays high until the next sweep starts. The output valid signal is available at a rear panel BNC connector. This output is a TTL signal that goes high when output frequency, output amplitude, or modulation is potentially unsettled.

mostra più dettagli

Manuale di servizio
Tipo di manuale:
Manuale di servizio
Pagine:
50
Dimensione:
2.12 Mbytes (2222424 Bytes)
Lingua:
english
Revisione:
ID del manuale:
578054
Data:
1982 01 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2018 01 20
MD5:
043c2f1246a4f43d09e4fb2ba097ec8f
Scaricamenti:
1434

Informazioni

THE 6070A.6071A SERVICE MANUAL 1-5. The information in this, the 6070A.6071A Service Manual, is divided into eight sections: 1 INTRODUCTION Introduces the 6070A.6071A Instruction Manual set and the 6070A/607IA Service Manual. 2 THEORY OF OPERATION Describes the theory of operation under three headings: Software, Theory of Operation, and Circuit Analysis. 3 ACCESS PROCEDURE Describes the procedures necessary to gain access to each major assembly and to gain access to each circuit board inside the instrument. 4 TROUBLESHOOTING Contains troubleshooting information that aids the technician in locating an indicated trouble to a particular assembly. 5 NONROUTINE ADJUSTMENT PROCEDURE Describes Non-routine Adjustment Procedures. These maintenance procedures are usually performed after removal and replacement of circuit board components. 6 LIST OF REPLACEABLE PARTS Contains the list of replaceable parts for the 6070A and the 6071 A. 7 OPTIONS Contains the Options Access Procedures. 8 BACKDATING Contains addenda and manual change information. 1-6. LIST OF RECOMMENDED TEST EQUIPMENT 1-7. The test equipment recommended for servicing the 6070A 6071A/is listed in Section 1 of the 6070A.6071A Calibration Manual. If the recommended test equipment is not available, equivalent test equipment can be used. 1-8. 6070A.6071A SPECIFICATIONS 1-9. The 6070A.6071A specifications are contained in Section 1 of the Calibration Manual. 1-10. Fluke SALES AND SERVICE CENTERS 1-11. A list of Fluke Sales and Service Centers is located in Appendix A of the 6070A.6071A Calibration Manual. 1-12. SHIPPING AND SERVICE INFORMATION 1-13. Shipping and service information is contained in Section 2 of the 6070A.6071A Calibration Manual.

mostra più dettagli

Scheda tecnica
Tipo di manuale:
Scheda tecnica
Pagine:
4
Dimensione:
388.57 Kbytes (397899 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2016 01 28
MD5:
2c954ed50d8e27cba138511efb1af602
Scaricamenti:
1097
Manuale di servizio
Tipo di manuale:
Manuale di servizio
Pagine:
63
Dimensione:
1.80 Mbytes (1886038 Bytes)
Lingua:
english
Revisione:
ID del manuale:
577551
Data:
1981 02 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2018 01 20
MD5:
b82ffb8678b07ece0a020fab4ee9f9bd
Scaricamenti:
1368

Informazioni

1-4. THE 6070A.6071A CALIBRATION MANUAL 1-5. The information in this, the 6070A.6071A Calibration Manual is divided into seven sections: 1 INTRODUCTION AND SPECIFICATIONS Introduces the 6070A.6071A Instruction Manual set and the 6070A.6071A Calibration Manual and list the specifications of the instrument and the test equipment required to complete the performance checks and the calibration procedures. 2 SHIPPING AND SERVICE INFORMATION Describes how to ship the instrument and how to get problems corrected. 3 ACCESS PROCEDURES Describes the procedures necessary to gain access to each circuit inside the instrument. 4 GENERAL MAINTENANCE PROCEDURES Describes procedures for cleaning the instrument, for selecting a different line power configuration, and for changing fuses. 5 PERFORMANCE CHECKS Describes procedures to verify proper operation of the instrument. 6 ADJUSTMENT PROCEDURE Describes procedures for making all routine adjustments and describes the procedure used to reprogram the Calibration EPROM. 7 PERFORMANCE CHECKS AND CALIBRATION OF OPTIONS Describes the procedure for completing the performance checks and calibration procedures required by instruments with options installed. Each option has a separate subsection.

mostra più dettagli

Manuale di servizio
Tipo di manuale:
Manuale di servizio
Pagine:
306
Dimensione:
12.16 Mbytes (12755678 Bytes)
Lingua:
english
Revisione:
ID del manuale:
578054
Data:
1982 01 01
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2020 10 20
MD5:
bfb619571051312f71c2e35222984c8a
Scaricamenti:
495

Informazioni

1 INTRODUCTION ... 1-1 1-1. THE MANUAL SET ... 1-1 1-4. THE 6070A.6071A SERVICE MANUAL ... 1-2 1-6. LIST OF RECOMMENDED TEST EQUIPMENT ... 1-2 1-8. 6070A/607IA SPECIFICATIONS ... 1-2 1-10. FLUKE SALES AND SERVICE CENTERS ... 1-2 M2. SHIPPING AND SERVICE INFORMATION ... 1-2 2 THEORY OF OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SOFTWARE OPERATION ... 2-1 2-4. Introduction ... 2-1 2-12. Software Function ... 2-2 2*15. Software at Work ... 2-2 2-23. Software Management of the Hardware ... 2-2 2-82. THEORY OF OPERATION ... 2-8 2-83. Introduction ... 2-8 2-85. Physical Layout ... 2-8 2-96. Frequency Bands ... 2-9 2-98. Level Control ... 2-9 2-100. Frequency Synthesis ... 2-9 2-103. Angle Modulation ... 2-10 2-106. DCFM ... 2-10 2-108. DETAILED CIRCUIT ANALYSIS ... 2-10 2-109. Introduction ... 2-10 2-121. A2A 1 PCB Circuit Controller Analysis ... 2-11 2-141. A2A2 Non-Volatile Memory PCB Circuit Analysts (Option -570) ... 2-12 2-147. A3A1 Phase Detector PCB Circuit Analysis ... 2-12 2-158. A3A2 10 MHz Reference PCB Circuit Analysis ... 2-13 2-181. A3A3 Delay Discriminator PCB Circuit Analysis ... 2-18 2-198. A3A4 N/l Divider PCB Circuit Analysis ... 2-20 2-224. A3A5, A3A10 VCO Resonator PCB Circuit Analysis ... 2-22 2-229. A3A6 Single Sideband Mixer (SSB Mixer) PCB Circuit Analysis ... 2-25 2-248. A3A7 Sub-Synthesizer PCB Circuit Analysis ... 2-29 2-260. A3A8 Synthesizer Control Buffer PCB Circuit Analysis ... 2-30 2-263. A3A9 Synthesizer Distribution PCB Circuit Analysis ... 2-30 2-266. A4A2 Modulation Oscillator PCB Circuit Analysts ... 2-31 2-276. A4A3 Attenuator PCB Circuit Analysis ... 2-32 2-280. A4A4 Modulator Divider PCB Circuit Analysis ... 2-32 2-289, A4A5 Reverse Power Protection PCB Circuit Analysis (Option -870) ... 2-33 2-292. A4A6 Times Two Output Amplifier PCB Circuit Analysis /6071A Only) .. 2-34 2-300. A4A7 Output Amplifier PCB Circuit Analysis /6070A Only) ... 2-35 2-309. A4A8 Heterodyne Oscillator PCB Circuit Analysis ... 2-36 2-315. A4A9 Heterodyne Converter PCB Circuit Analysis ... 2-37 2-321. A4A10 Modulation Distribution PCB Circuit Analysis ... 2*37 2-333. 6070A 6071A/Power Supply ... 2-39 3 ACCESS PROCEDURE ... 3-1 3-1. INTRODUCTION ... 3-1 3-3. LOCATION OF MAJOR ASSEMBLIES ... 3-1 3-5. INTERIOR ACCESS PROCEDURE ... 3-1 3-6. Introduction ... 3-1 3-8. Disassembly Procedure ... 3-1 3-10. Assembly Procedure ... 3-1 3-12. A3A3 AND A3A5 PRINTED CIRCUIT BOARDS ACCESS PROCEDURE ... 3-1 3-13. Introduction ... 3-1 3-15. Disassembly Procedure ... 3-1 3-17. Assembly Procedure ... 3-9 3-19. A3A2, A3A4, AND A3A9 PRINTED CIRCUIT BOARD ACCESS PROCEDURE ... 3-9 3-20. Introduction ... 3-9 3-22. Disassembly Procedure ... 3-9 3-24. Assembly Procedure ... 3-9 3-26. A3A1, A3A6* A3A7, A3A8 AND A3A10 PRINTED CIRCUIT BOARDS ACCESS PROCEDURE ... 3-9 3-27. Introduction ... 3-10 3-29. Disassembly Procedure ... 3-10 3-31. Assembly Procedure ... 3-11 3-33. A4A2, A4A6, A4A7, A4A9, AND A4A10 PRINTED CIRCUIT BOARDS ACCESS PROCEDURE ... 3-11 3-34. Introduction ... 3-11 3-36. Disassembly Procedure ... 3-11 3-38. Assembly Procedure ... 3-11 3-40. A3 A3 PRINTED CIRCUIT BOARD ACCESS PROCEDURE ... 3-19 3-41. Introduction ... 3-19 3-43. Disassembly Procedure ... 3-19 3-45. Assembly Procedure ... 3-19 3-47. A4A4 AND A4A8 PRINTED CIRCUIT BOARDS ACCESS PROCEDURE 3-20 3-48. Introduction ... 3-20 3-50. Disassembly Procedure ... 3-21 3-52. Assembly Procedure ... 3-21 3-54. Power supply ACCESS PROCEDURE ... 3-21 3-55. Introduction ... 3-23 3-57. Disassembly Procedure ... 3-23 3-59. Assembly Procedure ... 3-23 3-61. DELAY CABLE ASSEMBLY ACCESS PROCEDURE ... 3-23 3-62. Introduction ... 3-24 3-64. Disassembly Procedure ... 3-24 3-66. Assembly Procedure ... 3-24 3-68. FRONT PANEL/CONTROLLER ASSEMBLY ACCESS PROCEDURE .. 3-24 3-69. Introduction ... 3-24 3-7L Disassembly Procedure ... 3-24 3-73. Assembly Procedure ... 3-25 3-75. ENCODER ASSEMBLY ACCESS PROCEDURE ... 3-25 3-76. Introduction ... 3-25 3-78. Disassembly Procedure ... 3-25 3-80. Assembly Procedure ... 3-25 3-82. Al Al FRONT PANEL ASSEMBLY PRINTED CIRCUIT BOARD PROCEDURE ... 3-25 3-83. Introduction ... 3-25 3-85. Disassembly Procedure ... 3-25 3-87. Assembly Procedure ... 3-27 3-89 A2A1 CONTROLLER PRINTED CIRCUIT BOARD ACCESS PROCEDURE AND A2A4 CONTROLLER MOTHERBOARD ACCESS PROCEDURE . 3-27 3-90. Introduction ... 3-27 3-92. Disassembly Procedure ... 3-27 3-94. Assembly Procedure ... 3-27 3-96. A6AI IEEE CONNECTOR PCB ACCESS PROCEDURE ... 3-28 3-97. Introduction ... 3-29 3-99. Disassembly Procedure ... 3-29 3-101. Assembly Procedure ... 3-29 4 TROUBLESHOOTING ... 4-1 4-1. INTRODUCTION ... 4-1 4-4. ACCESS AND ASSEMBLY IDENTIFICATION ... 4-1 4-6. TROUBLESHOOTING ... 4-1. 4-8. Error Codes (Self Check) at Power-On ... 4-1 4-11. UNCAL Annunciator Error Codes ... 4-1 4-13. Front Panel Connectors ... 4-2 4-15. Rear Panel BNC Connectors ... 4-2 4-17. Printed Circuit Board Adjustable Components and Controls ... 4-4. 4-19. Printed Circuit Board Switches ... 4-4 4*21. A3A3 Discriminator PCB, Replacement Parts, and EPROM Calibration Information ... 4-4 4-24. A3A5, A3 A10, VCO Resonator PCB ... 4-4. 4-26. A4A3 Attenuator PCB, Replaceable Parts and EPROM Calibration Information ... 4-4 4-29. A4A6 X2 Output Amplifier PCB Replaceable Parts and Procedures ... 4-11 4-32. A4A7 Output Amplifier PCB, Replaceable Parts and Procedures ... 4-11 4-35. A4A8 Heterodyne Oscillator PCB, Replacement Parts and Factory Service Information ... 4-11 4-37, 607XA-870 Reverse Power Protection Option (RPP) ... 4-13 5 NON-ROUTINE ADJUSTMENTS ... 5-1 5-1. INTRODUCTION ... 5-1 5-3. ACCESS AND ASSEMBLY IDENTIFICATION ... 5-1 5-5. ADJUSTMENT CONTROLS ... 5-1 5-7. TEST EQUIPMENT REQUIRED ... 5-1 5-9. NON-ROUTINE ADJUSTMENT PROCEDURES ... 5-1 5-11* A3AI Phase Detector PCB ... 5-1 5-14. A3A3 Discriminator ... 5-2 5-19. A3A6 Single Sideband Mixer (CONTROL R30) ... 5-2 5-22. A3A6 Single Sideband Mixer (CONTROLS R51 and R52) ... 5-3 5-25. A3A7 Sub-Synthesizer PCB ... 5-4 5-28. A3A9 Synthesizer Distribution PCB ... 5-5 5-31. A4A2 Modulation Oscillator PCB ... 5-5 5-34. A4A4 Modulator Divider PCB ... 5-6 5-37. A4A6 X2 Output Amplifier Service Routine Adjustment ... 5-7 5-41. A4A6 X2 Output Amplifier Subharraonic Adjustment Procedure ... 5-8 5-45. A4A7 Output Amplifier Service Routine Adjustment ... 5-9 5-49. A4A9 Heterodyne Converter PCB ... 5-11 5-52. A4A10 Modulation Distribution PCB ... 5-12 5-54. AC ADJUSTMENTS ... 5-12 5-55. DC ADJUSTMENTS ... 5-12 5-56. AM ADJUSTMENTS ... 5-13 6 LIST OF REPLACEABLE PARTS ... 6-1 TABLE OF CONTENTS ... 6-I 6-1. INTRODUCTION ... 6-2 6-4. HOW TO OBTAIN PARTS ... 6-2 7 OPTION INFORMATION ... 7-1 APPENDIX A ... A-1

mostra più dettagli

Manuale d'uso
Tipo di manuale:
Manuale d'uso
Pagine:
30
Dimensione:
983.52 Kbytes (1007121 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2017 04 30
MD5:
da96205ad69f8018af9a769e221fb7ed
Scaricamenti:
1118